Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- AZ 300 MIF Developer
- Product Code
- 187833
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Materials for use in technical applications
Manufacturers & Suppliers
Merck KGaA
manufacturer
64271 Darmstadt * Germany
+49 6151 72-0
Merck Chemicals Ltd
national supplier
Boulevard Industrial Park * Padge Road * Beeston * Nottingham * NG9 2JR
01159 430840
Emergency Contacts
Emergency Contact
+49 (0) 6151 722440
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS06
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Tetramethylammonium hydroxide | 75-59-2 | 1 - 2.5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
fresh air. Immediately call in physician. If breathing stops: immediately apply artificial respiration, if necessary also oxygen.
Symptoms: Cough, Shortness of breath, respiratory arrest
Take off immediately all contaminated clothing. Rinse skin with water/ shower. Call a physician immediately. If a systemic effect is suspected, monitoring and treatment in an intensive care unit is urgently required.
Symptoms: Irritation and corrosion
rinse out with plenty of water. Immediately call in ophthalmologist. Remove contact lenses.
Symptoms: Risk of blindness!
make victim drink water (two glasses at most), avoid vomiting (risk of perforation). Call a physician immediately. Do not attempt to neutralise.
Symptoms: Nausea, Vomiting, Abdominal pain, Diarrhoea
Immediate Medical Attention
Immediately call in physician.
Medical Treatment
If a systemic effect is suspected, monitoring and treatment in an intensive care unit is urgently required.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
For this substance/mixture no limitations of extinguishing agents are given.
Not combustible. Ambient fire may liberate hazardous vapours.
Suppress (knock down) gases/vapours/mists with a water spray jet.
Firefighter Protection
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not breathe vapours, aerosols. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not flush into surface water or sanitary sewer system.
Cover drains. Collect, bind, and pump off spills. Take up carefully with liquid-absorbent material (e.g. Chemizorb®). Dispose of properly. Clean up affected area.
Materials: liquid-absorbent material (e.g. Chemizorb®)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Observe label precautions.
Store in original container. No metal containers. Tightly closed. Keep in a well-ventilated place. Keep locked up or in an area accessible only to qualified or authorised persons.
Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.
full contact Glove material : natural latex Glove thickness : 0.6 mm Break through time : 480 min splash contact Glove material : Nitrile rubber Glove thickness : 0.11 mm Break through time : 10 min The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example:KCL 706 Lapren®(full contact);KCL 741 Dermatril® L(splash contact). The breakthrough times stated above were determined by KCL in laboratory tests acc. to EN374 with samples of the recommended glove types.
Tightly fitting safety goggles
required when vapours/aerosols are generated. Recommended Filter type: Filter A-(P2) The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
Protective clothing needs to be selected specifically for the workplace, depending on concentrations and quantities of the hazardous substances handled and must meet the specifications of a standard EN/ISO/DIN. The chemical resistance of the protective equipment should be enquired at the respective supplier. Full protective suit
Do not flush into surface water or sanitary sewer system.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
See section 10.3
Violent reactions possible with: The generally known reaction partners of water. Risk of explosion with: Potassium peroxide. Risk of ignition or formation of inflammable gases or vapours with: Metals
no information available
Metals (Aluminium, Zinc, Tin, bronze). Gives off hydrogen by reaction with metals.
in the event of fire: See section 5.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
No data available
12.1 Toxicity
12.2 Persistence and degradability
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
No data available for the product or components.
12.5 Results of PBT and vPvB assessment
The product does not contain components considered to be PBT or vPvB at levels of 0.1% or higher. Tetramethylammonium hydroxide does not meet the criteria for PBT or vPvB.
12.6 Other adverse effects
Discharge into the environment must be avoided.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Notice Directive on waste 2008/98/EC.
Leave chemicals in original containers. No mixing with other waste.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1835
- Shipping Name
- TETRAMETHYLAMMONIUM HYDROXIDE SOLUTION
- Transport Class
- 8
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Take note of Dir 94/33/EC on the protection of young people at work. Observe work restrictions regarding maternity protection in accordance to Dir 92/85/EEC or stricter national regulations where applicable.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for AZ 300 MIF Developer?
The signal word is danger.
What is the physical form of AZ 300 MIF Developer?
AZ 300 MIF Developer is a liquid with colourless color. It has slight characteristic odor.
What is the solubility of AZ 300 MIF Developer?
No information available.
What is AZ 300 MIF Developer used for?
Materials for use in technical applications
What are the hazard statements for AZ 300 MIF Developer?
This substance has 6 hazard statements:
- H290: May be corrosive to metals.
- H302: Harmful if swallowed.
- H311: Toxic in contact with skin.
- H314: Causes severe skin burns and eye damage.
- H371: May cause damage to organs (Central nervous system).
- H373: May cause damage to organs (Liver, thymus gland) through prolonged or repeated exposure.
What is the melting point of AZ 300 MIF Developer?
The melting point is No information available. and the boiling point is ca. 100 °C at 1,013 hPa.