Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ICAFLEX ADB595
- Product Code
- 4212
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Industrial user (SU3) Adhesives, binding agents.
Manufacturers & Suppliers
ICAP-SIRA CHEMICALS AND POLYMERS S.P.A.
manufacturer
Via F.Corridoni 19 20015 Parabiago (MI) Italia
Emergency Contacts
ICAP-SIRA Chemicals and polymers S.P.A.
+39 0331 496111
Monday to Friday 08.00-12.30 14.00-18.00 UTC/GMT +1
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove casualty to fresh air and keep warm and at rest.
Symptoms: Cough, Dizziness, Drowsiness, Headache, Nausea
Remove contaminated clothing immediately and dispose off safely. Wash thoroughly the body (shower or bath). After contact with skin, wash immediately with soap and plenty of water.
After contact with the eyes, rinse with water with the eyelids open for a sufficient length of time, then consult an ophthalmologist immediately. Protect uninjured eye.
Do not under any circumstances induce vomiting. OBTAIN A MEDICAL EXAMINATION IMMEDIATELY.
Immediate Medical Attention
OBTAIN A MEDICAL EXAMINATION IMMEDIATELY.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
use dry powder, CO2, foam for extinction. Never use water.
Water. In case of fire of insoluble products / immiscible in water, the use of water, increase the risk of propagation of the area of fire.
Do not inhale explosion and combustion gases. Burning produces heavy smoke. When heated (decomposition) or in case of fire may liberate carbon oxides, gases and vapors which are dangerous to health.
Move undamaged containers from immediate hazard area if it can be done safely.
Firefighter Protection
Use suitable breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Remove persons to safety.
Do not allow to enter into soil/subsoil. Do not allow to enter into surface water or drains. Retain contaminated washing water and dispose it.
Wash with plenty of water.
Materials: absorbing material, organic, sand
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin and eyes, inhalation of vapours and mists. Don't use empty container before they have been cleaned. Before making transfer operations, assure that there aren't any incompatible material residuals in the containers.
Store in sealed original container protected against moisture. Ensure good ventilation/extraction. Keep container tightly sealed and store in a frost free place. Store in a cool, dry place. Always keep in a well ventilated place. Keep away from unguarded flame, sparks, and heat sources. Avoid direct exposure to sunlight. Avoid accumulating electrostatic charge. Keep away from food, drink and feed.
Contaminated clothing should be changed before entering eating areas. Do not eat or drink while working.
Keep away from unguarded flame, sparks, and heat sources. Avoid accumulating electrostatic charge.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Always provide good ventilation to maintain air contaminants below exposure limits (it is advisable to work under vacuum system). See also section 7 and section 13.
CR (polychloroprene, chloroprene rubber) 0,4-0,6 mm; NBR (nitrile rubber). 0,4-0,6 mm
Eye glasses with side protection.
Use adequate protective respiratory equipment. Ensure good ventilation to maintain air contaminants below exposure limits. Use respiratory protection filters for gas / vapor (Type A / AX brown, ref. Standard EN 141) as a function of the levels of occupational exposure to chemical agents.
Chemical protection clothing.
See data PNEC. See also section 6.2 and 13.1. Prevent spills into public sewers or the immediate environment. Do not empty into drains; dispose of this material and its container at a collection point for hazardous waste and in accordance with local regulations. Refer to applicable national and Community legislation concerning environmental protection, waste water, soil pollution and integrated pollution prevention and control (ex. IPPC). Check whether the activity that uses the product falls within the scope of Directive 96/61/EC (IPPC). The emissions from ventilation or work process equipment should be checked to ensure compliance with the directives of the binding legislation on environmental protection. In some cases, to reduce emissions, might be needed maintenance or technical plant modifications.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
It may generate dangerous reactions (See subsections below)
It may generate dangerous reactions (See subsections below)
It may generate flammable gases on contact with elementary metals (alkalis and alkaline earth), and nitrides. It may catch fire on contact with oxidising mineral acids, powerful oxidising agents, and powerful reducing agents.
Avoid accumulating electrostatic charge.
Avoid contact with combustible materials. The product could catch fire.
None known. When heated (decomposition) or in case of fire may liberate carbon oxides, gases and vapors which are dangerous to health.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1866
- Shipping Name
- RESIN SOLUTION
- Transport Class
- 3
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ICAFLEX ADB595?
The signal word is danger.
What is the physical form of ICAFLEX ADB595?
ICAFLEX ADB595 is a liquid appearing as liquid colorless with colorless color. It has solvent odor.
What is ICAFLEX ADB595 used for?
Industrial user (SU3) Adhesives, binding agents.
What are the hazard statements for ICAFLEX ADB595?
This substance has 3 hazard statements:
- H225: Highly flammable liquid and vapour.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
What is the melting point of ICAFLEX ADB595?
The melting point is N.A. and the boiling point is 77°C.