Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ROBOND™ FD-07
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- 96MU-R1JM-U00S-XDQU
Identified Uses
Adhesive and Coating
Manufacturers & Suppliers
DOW EUROPE GMBH
manufacturer
BACHTOBELSTRASSE 4, 8810 HORGEN, SWITZERLAND
31 115 67 2626
DOW BENELUX B.V.
national supplier
HERBERT H.DOWWEG 5, HOEK, 4542 NM TERNEUZEN, NETHERLANDS
(31) 115 67 2626
Emergency Contacts
Emergency Contact
00 41 447 28 2820
24-Hour
Emergency Contact
+39 333 210 7947
CAV "Osp. Pediatrico Bambino Gesù" Dip. Emergenza e Accettazione DEA, Piazza Sant'Onofrio 4, 165, Roma
06-68593726
Az. Osp. Univ. Foggia, V.le Luigi Pinto 1, 71122, Foggia
800183459
Az. Osp. "A. Cardarelli", Via A. Cardarelli 9, 80131, Napoli
081-5453333
CAV Policlinico "Umberto I", V.le del Policlinico 155, 161, Roma
06-49978000
CAV Policlinico "A. Gemelli", Largo Agostino Gemelli 8, 168, Roma
06-3054343
Az. Osp. "Careggi" U.O. Tossicologia Medica, Largo Brambilla 3, 50134, Firenze
055-7947819
CAV Centro Nazionale di Informazione Tossicologica, Via Salvatore Maugeri 10, 27100, Pavia
0382-24444
Osp. Niguarda Ca' Granda, Piazza Ospedale Maggiore 3, 20162, Milano
02-66101029
Azienda Ospedaliera Papa Giovanni XXII, Piazza OMS 1, 24127, Bergamo
800883300
Azienda Ospedaliera Integrata Verona, Piazzale Aristide Stefani 1, 37126, Verona
800011858
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| ammonia EC: 215-647-6 | 1336-21-6 | 0.1 - 0.25% | Yes |
| 2-methylisothiazol-3(2H)-one EC: 220-239-6 | 2682-20-4 | 0.0025 - 0.025% | Yes |
| reaction mass of 5-chloro-2-methyl-2H-isothiazol-3-one and 2-methyl-2H-isothiazol-3-one (3:1) EC: 611-341-5 | 55965-84-9 | 0.0002 - 0.0015% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move person to fresh air and keep comfortable for breathing; consult a physician.
Remove material from skin immediately by washing with soap and plenty of water. Remove contaminated clothing and shoes while washing. Seek medical attention if irritation or rash occurs. Wash clothing before reuse. Discard items which cannot be decontaminated, including leather articles such as shoes, belts and watchbands.
Symptoms: May cause an allergic skin reaction.
Flush eyes thoroughly with water for several minutes. Remove contact lenses after the initial 1-2 minutes and continue flushing for several additional minutes. If effects occur, consult a physician, preferably an ophthalmologist.
If swallowed, seek medical attention. Do not induce vomiting unless directed to do so by medical personnel.
Immediate Medical Attention
Consult a physician if effects occur or if irritation/rash occurs.
Medical Treatment
Treatment of exposure should be directed at the control of symptoms and the clinical condition of the patient.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing media appropriate for surrounding fire..
No data available
Material can splatter above 100C/212F.. Dried product can burn..
No data available
Firefighter Protection
Wear self-contained breathing apparatus and protective suit..
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment. Keep people away from and upwind of spill/leak. Material can create slippery conditions.
CAUTION: Keep spills and cleaning runoff out of municipal sewers and open bodies of water.
Transfer liquids and solid diking material to separate suitable containers for recovery or disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with eyes, skin and clothing. Wash thoroughly after handling. Keep container tightly closed. Do not breathe vapors, mist or gas.
Keep container tightly closed.
Wash thoroughly after handling.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use local exhaust ventilation, or other engineering controls to maintain airborne levels below exposure limit requirements or guidelines. If there are no applicable exposure limit requirements or guidelines, general ventilation should be sufficient for most operations.
Use chemical resistant gloves classified under Standard EN374: Protective gloves against chemicals and micro-organisms. Examples of preferred glove barrier materials include: Nitrile/butadiene rubber ("nitrile" or "NBR"). Polyvinyl chloride ("PVC" or "vinyl"). Neoprene. When prolonged or frequently repeated contact may occur, a glove with a protection class of 5 or higher (breakthrough time greater than 240 minutes according to EN 374) is recommended. When only brief contact is expected, a glove with a protection class of 3 or higher (breakthrough time greater than 60 minutes according to EN 374) is recommended. Glove thickness alone is not a good indicator of the level of protection a glove provides against a chemical substance as this level of protection is also highly dependent on the specific composition of the material that the glove is fabricated from. The thickness of the glove must, depending on model and type of material, generally be more than 0.35 mm to offer sufficient protection for prolonged and frequent contact with the substance. As an exception to this general rule it is known that multilayer laminate gloves may offer prolonged protection at thicknesses less than 0.35 mm. Other glove materials with a thickness of less than 0.35 mm may offer sufficient protection when only brief contact is expected. NOTICE: The selection of a specific glove for a particular application and duration of use in a workplace should also take into account all relevant workplace factors such as, but not limited to: Other chemicals which may be handled, physical requirements (cut/puncture protection, dexterity, thermal protection), potential body reactions to glove materials, as well as the instructions/specifications provided by the glove supplier.
Use safety glasses (with side shields). Safety glasses (with side shields) should be consistent with EN ISO 16321-1 or equivalent.
Respiratory protection should be worn when there is a potential to exceed the exposure limit requirements or guidelines. If there are no applicable exposure limit requirements or guidelines, wear respiratory protection when adverse effects, such as respiratory irritation or discomfort have been experienced, or where indicated by your risk assessment process. For most conditions no respiratory protection should be needed; however, if discomfort is experienced, use an approved air-purifying respirator. Use the following CE approved air-purifying respirator: Particulate filter, type P2 (meeting standard EN 143).
Use protective clothing chemically resistant to this material. Selection of specific items such as face shield, boots, apron, or full body suit will depend on the task.
See SECTION 7: Handling and storage and SECTION 13: Disposal considerations for measures to prevent excessive environmental exposure during use and waste disposal.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable
No data available
None known. Product will not undergo polymerization.
No data available
There are no known materials which are incompatible with this product.
Thermal decomposition may yield acrylic monomers..
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
Product test data not available.
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and degradability
Product test data not available.
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.3 Bioaccumulative potential
Product test data not available.
12.3 Bioaccumulative potential
No bioconcentration is expected because of the relatively high water solubility.
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
Bioconcentration potential is low (BCF < 100 or Log Pow < 3).
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
Product test data not available. No data available for components.
12.6 Endocrine disrupting properties
The product and its components (ammonia, 2-methylisothiazol-3(2H)-one, and the reaction mass of 5-chloro-2-methyl-2H-isothiazol-3-one and 2-methyl-2H-isothiazol-3-one) are not considered to have endocrine disrupting properties according to the specified EU regulations at levels of 0.1% or higher.
12.7 Other adverse effects
No product test data available. Components listed are not on the Montreal Protocol list of substances that deplete the ozone layer.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Coagulate the emulsion by the stepwise addition of ferric chloride and lime. Remove the clear supernatant and flush to a chemical sewer.
For disposal, incinerate or landfill at a permitted facility in accordance with local, state, and federal regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This product contains only components that have been either registered, are exempt from registration, are regarded as registered or are not subject to registration according to Regulation (EC) No. 1907/2006 (REACH). Polymers are exempted from registration under REACH.
Take note of Directive 94/33/EC on the protection of young people at work or stricter national regulations, where applicable.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ROBOND™ FD-07?
The signal word is warning.
What is the physical form of ROBOND™ FD-07?
ROBOND™ FD-07 is a liquid milky with white color. It has no data available odor.
What is ROBOND™ FD-07 used for?
Adhesive and Coating
What are the hazard statements for ROBOND™ FD-07?
This substance has 1 hazard statement:
- H317: May cause an allergic skin reaction.
What is the melting point of ROBOND™ FD-07?
The melting point is not determined and the boiling point is 100 °C Water.