Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- REFRACAST Nanobond F-70 AL
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Refractory lining for industrial applications.
Manufacturers & Suppliers
Refratechnik Steel GmbH
manufacturer
Schiess-Strasse 58, D-40549 Duesseldorf
+49 211 58 58 0
Emergency Contacts
Dpt. Research & Development
+49 211 58 58 171
during the regular office hours
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Refractory product based on fireclay
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| aluminium oxide EC: 215-691-6 | 1344-28-1 | 25 - 80% | Yes |
| Fumes, silica | 69012-64-2 | 3% | Yes |
| Clays, flint, calcined | 93821-35-3 | 25 - 80% | No |
| Polypropylene | 9003-07-0 | 3% | No |
For the wording of the listed hazard phrases refer to section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
In case of inhalation of dust remove to fresh air.
After skin contact with the dust wash with plenty of warm water and soap.
After contact with dust flush open eyes with running water during several minutes. If the trouble persists seek medical advice.
After ingestion of dust rinse out mouth and drink plenty of water.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use fire extinguishing methods suitable to surrounding conditions.
No further relevant information available.
Firefighter Protection
No special measures required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not allow to enter sewers/ surface or ground water.
pick up mechanically
Related Products
Similar products with comparable safety profiles
REFRACAST Nanobond B-90 AL
---
Alu-Cast 85 HS
---
ARCOL® POLYOL F-3040
---
FERROCOTE™ 5856 BF T1
---
Fosroc Galvafroid
---
Advancal, AnnaSicon 24, AnnaSicon 25, CN 137, CN 159, REFRAX® ARC, REFRAX® Basic, REFRAX® Pro, REFRAX® Plus, REFRAX® SBF, Sicanit Al3, N-SiC 2165, N-SiC 2172
---
FAG Arcanol LOAD1000
---
FAG Arcanol LOAD1000
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Prevent formation of dust. Have ready for use an eye wash right next to the working place.
Do not store near to a fire or other heat sources. Store in dry conditions.
Have ready for use an eye wash right next to the working place.
Do not store near to a fire or other heat sources.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
In case of work with machines (e.g. cutting and grinding machines) ensure extraction system or sufficient ventilation.
The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.
Tightly sealed goggles. Face protection.
Breathing protection necessary. Filter type P1 - P3, depending on the dust concentration.
Tight-fitting protective work clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known.
No further relevant information available.
No further relevant information available.
No dangerous decomposition products known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Disposal must be made according to official regulations.
Before elimination: Check whether the product has absorbed further substances during its use, and therefore has to be assigned to another waste group than initially recommended.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Void
- Shipping Name
- Void
- Transport Class
- Void
- Packing Group
- Void
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for REFRACAST Nanobond F-70 AL?
The signal word is no signal word.
What is the physical form of REFRACAST Nanobond F-70 AL?
REFRACAST Nanobond F-70 AL is a dry mix of coarse and fine fractions appearing as dry mix of coarse and fine fractions with light grey color. It has specific type odor.
What is REFRACAST Nanobond F-70 AL used for?
Refractory lining for industrial applications.
What is the melting point of REFRACAST Nanobond F-70 AL?
The melting point is Undetermined. and the boiling point is Undetermined..