NextSDS Logo
Safety Data Sheet EN

REFRACAST Nanobond F-70 AL

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
REFRACAST Nanobond F-70 AL

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Refractory lining for industrial applications.

Manufacturers & Suppliers

R

Refratechnik Steel GmbH

manufacturer

Schiess-Strasse 58 D-40549 Duesseldorf

+49 211 58 58 0

Emergency Contacts

Dpt. Research & Development

+ 49 211 58 58 171

(during the regular office hours)

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Refractory product based on fireclay

Chemical Name CAS Number Concentration Hazardous
aluminium oxide EC: 215-691-6 1344-28-1 25 - 80% Yes
Fumes, silica Amorphous silicon dioxide particles from the volatilization and vaporization of furnace feed materials in the manufacture of ferrosilicon and silicon. EC: 273-761-1 69012-64-2 3% Yes
Clays, flint, calcined 93821-35-3 25 - 80% No
polypropylene EC: 618-352-4 9003-07-0 3% No

For the wording of the listed hazard phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of inhalation of dust remove to fresh air.

Skin contact

After skin contact with the dust wash with plenty of warm water and soap.

Eye contact

After contact with dust flush open eyes with running water during several minutes. If the trouble persists seek medical advice.

Ingestion

After ingestion of dust rinse out mouth and drink plenty of water.

Immediate Medical Attention

No further relevant information available.

Medical Treatment

No further relevant information available.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

In case of work with machines (e.g. cutting and grinding machines)ensure extraction system or sufficient ventilation.

Hands

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Tightly sealed goggles Face protection

Respiratory

Breathing protection necessary. Filter type P1 - P3, depending on the dust concentration.

Skin/Body

Tight-fitting protective work clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Dry mix of coarse and fine fractions
Physical State Data
solid
State Under Standard Conditions
---
Appearance
Dry mix of coarse and fine fractions, Light grey
Colour
Light grey
Colour Intensity
---
Form
Dry mix of coarse and fine fractions
Odor
Specific type
Odor Threshold
Not determined.
Ph
9
Melting Point
Undetermined.
Boiling Point
Undetermined.
Flash Point
Not applicable.
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not applicable.
Vapor Pressure
Not applicable.
Vapor Density
Not applicable.
Relative Density
Not determined.
Bulk Density
---
Density
(~) See technical data sheet.
Flammability
Not determined.
Upper Explosive Limit
Not determined.
Lower Explosive Limit
Not determined.
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
Not determined.
Solubility
---
Partition Coefficient
Not determined.
Solubility In Water
Insoluble.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Not applicable.
Kinematic Viscosity
Not applicable.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for REFRACAST Nanobond F-70 AL?

The signal word is no signal word.

What is the physical form of REFRACAST Nanobond F-70 AL?

REFRACAST Nanobond F-70 AL is a dry mix of coarse and fine fractions appearing as dry mix of coarse and fine fractions, light grey with light grey color. It has specific type odor.

What is REFRACAST Nanobond F-70 AL used for?

Refractory lining for industrial applications.

What is the melting point of REFRACAST Nanobond F-70 AL?

The melting point is Undetermined. and the boiling point is Undetermined..

Compliance Scanner

Scan your compliance