NextSDS Logo
Safety Data Sheet EN

REFRACAST Nanobond F-70 AL

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
REFRACAST Nanobond F-70 AL

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Refractory lining for industrial applications.

Manufacturers & Suppliers

R

Refratechnik Steel GmbH

manufacturer

Schiess-Strasse 58, D-40549 Duesseldorf

+49 211 58 58 0

Emergency Contacts

Dpt. Research & Development

+49 211 58 58 171

during the regular office hours

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Refractory product based on fireclay

Chemical Name CAS Number Concentration Hazardous
aluminium oxide EC: 215-691-6 1344-28-1 25 - 80% Yes
Fumes, silica 69012-64-2 3% Yes
Clays, flint, calcined 93821-35-3 25 - 80% No
Polypropylene 9003-07-0 3% No

For the wording of the listed hazard phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of inhalation of dust remove to fresh air.

Skin contact

After skin contact with the dust wash with plenty of warm water and soap.

Eye contact

After contact with dust flush open eyes with running water during several minutes. If the trouble persists seek medical advice.

Ingestion

After ingestion of dust rinse out mouth and drink plenty of water.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use fire extinguishing methods suitable to surrounding conditions.

Specific hazards

No further relevant information available.

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

pick up mechanically

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Prevent formation of dust. Have ready for use an eye wash right next to the working place.

Storage

Do not store near to a fire or other heat sources. Store in dry conditions.

Hygiene

Have ready for use an eye wash right next to the working place.

Fire prevention

Do not store near to a fire or other heat sources.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

In case of work with machines (e.g. cutting and grinding machines) ensure extraction system or sufficient ventilation.

Hands

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Tightly sealed goggles. Face protection.

Respiratory

Breathing protection necessary. Filter type P1 - P3, depending on the dust concentration.

Skin/Body

Tight-fitting protective work clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Ph
9
Dynamic Viscosity
Not applicable.
State Under Standard Conditions
---
Vapor Density
Not applicable.
Flash Point
Not applicable.
Evaporation Rate
Not applicable.
Upper Explosive Limit
Not determined.
Physical State
Dry mix of coarse and fine fractions
Voc Content
---
Cloud Point
---
Properties Status
---
Solidification Point
---
Partition Coefficient
Not determined.
Solubility
---
Form
Dry mix of coarse and fine fractions
Auto Ignition Temperature
---
Relative Evaporation Rate
---
Bulk Density
---
Lower Explosive Limit
Not determined.
Vapor Pressure
Not applicable.
Colour
Light grey
Solubility In Fat
---
Appearance
Dry mix of coarse and fine fractions
Physical State Data
solid
Freezing Point
---
Odor Threshold
Not determined.
Solubility In Water
Insoluble.
Melting Point
Undetermined.
Colour Intensity
---
Relative Density
Not determined.
Density
See technical data sheet.
Softening Point
---
Boiling Point
Undetermined.
Kinematic Viscosity
Not applicable.
Flammability
Not determined.
Decomposition Temperature
Not determined.
Crystallisation Point
---
Explosive Limits
---
Metal Corrosion
---
Odor
Specific type
Molecular Weight
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Disposal must be made according to official regulations.

Disposal

Before elimination: Check whether the product has absorbed further substances during its use, and therefore has to be assigned to another waste group than initially recommended.

Waste Codes

16 11 03* other linings and refractories from metallurgical processes containing hazardous substances EWC
16 11 04 other linings and refractories from metallurgical processes other than those mentioned in 16 11 03 EWC
17 01 07 mixtures of concrete, bricks, tiles and ceramics other than those mentioned in 17 01 06 EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Void
Shipping Name
Void
Transport Class
Void
Packing Group
Void
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for REFRACAST Nanobond F-70 AL?

The signal word is no signal word.

What is the physical form of REFRACAST Nanobond F-70 AL?

REFRACAST Nanobond F-70 AL is a dry mix of coarse and fine fractions appearing as dry mix of coarse and fine fractions with light grey color. It has specific type odor.

What is REFRACAST Nanobond F-70 AL used for?

Refractory lining for industrial applications.

What is the melting point of REFRACAST Nanobond F-70 AL?

The melting point is Undetermined. and the boiling point is Undetermined..