Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- AMH Elecsys Ctr 1
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory chemicals, Refer to product literature for further details.
Manufacturers & Suppliers
Roche Diagnostics Deutschland GmbH
national supplier
Sandhoferstrasse 116 68305 Mannheim Deutschland
+496217590
Emergency Contacts
Werkschutzzentrale Roche Diagnostics GmbH
+49(0)621-759-2203
Mainz
+49(0)6131-19240
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| N-Methylisothiazolone hydrochloride EC: 247-499-3 | 26172-54-3 | 0.25 - 1% | Yes |
| Disodium dihydrogen ethylenediaminetetraacetate EC: 205-358-3 | 139-33-3 | 0.1 - 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.
If on skin, rinse well with water.
Symptoms: May cause an allergic skin reaction.
Immediately flush eye(s) with plenty of water. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.
Keep respiratory tract clear. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician. Rinse mouth with water.
Medical Treatment
The first aid procedure should be established in consultation with the doctor responsible for industrial medicine.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
High volume water jet
Do not allow run-off from fire fighting to enter drains or water courses.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment. Avoid dust formation. Avoid breathing dust.
Prevent product from entering drains. Prevent further leakage or spillage if safe to do so.
Keep in suitable, closed containers for disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid formation of respirable particles. Do not breathe vapours/dust. Avoid exposure - obtain special instructions before use. Avoid contact with skin and eyes. For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. Dispose of rinse water in accordance with local and national regulations. Persons susceptible to skin sensitisation problems or asthma, allergies, chronic or recurrent respiratory disease should not be employed in any process in which this mixture is being used.
Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage.
Wash hands before breaks and at the end of workday.
Avoid dust formation.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Protective gloves. The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it. This recommendation is only valid for the product mentioned in the safety data sheet and provided by us and for the application specified by us. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. The suitability for a specific workplace should be discussed with the producers of the protective gloves.
Eye wash bottle with pure water; Tightly fitting safety goggles
Choose body protection according to the amount and concentration of the dangerous substance at the work place.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No dangerous reaction known under conditions of normal use.
No dangerous reaction known under conditions of normal use.
No data available
No data available
No decomposition if stored and applied as directed.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
Toxicity data on soil indicates it is not expected to adsorb. No data available for other organisms.
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.4 Mobility in soil
No data available
12.5 Results of PBT and vPvB assessment
The substance/mixture contains no components considered to be PBT or vPvB at levels of 0.1% or higher.
12.6 Endocrine disrupting properties
The substance/mixture does not contain components considered to have endocrine disrupting properties at levels of 0.1% or higher.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Send to a licensed waste management company. Can be disposed as waste water, when in compliance with local regulations.
The product should not be allowed to enter drains, water courses or the soil. Do not contaminate ponds, waterways or ditches with chemical or used container.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Relevant EU provisions transposed through retained EU law
Take note of The Management of Health and Safety at Work Regulations 1999 (requirements relating to protection of young people at work contained in Regulation 19) and of Directive 94/33/EC on the protection of young people at work.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for AMH Elecsys Ctr 1?
The signal word is warning.
What is the physical form of AMH Elecsys Ctr 1?
AMH Elecsys Ctr 1 is a solid appearing as (lyophilised) with yellow color. It has characteristic odor.
What is AMH Elecsys Ctr 1 used for?
Laboratory chemicals, Refer to product literature for further details.
What are the hazard statements for AMH Elecsys Ctr 1?
This substance has 2 hazard statements:
- H317: May cause an allergic skin reaction.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of AMH Elecsys Ctr 1?
The melting point is No data available and the boiling point is No data available.