NextSDS Logo
Safety Data Sheet EN

Elecsys AMH

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Elecsys AMH
Product Code
06331076190

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

R

Roche Diagnostic Canada

manufacturer

201 Boulevard Armand-Frappier, Laval, QC, H7V 4A2, Canada

1-877-273-3433

Emergency Contacts

CHEMTREC

1-800-424-9300

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Hazard Statements

Not a hazardous substance or mixture.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Albumins, blood serum 9048-46-8 1 - 5% No
#-D-Glucopyranoside, #-D-fructofuranosyl 57-50-1 1 - 5% No
1-Piperazineethanesulfonic acid, 4-(2-hydroxyethyl)- 7365-45-9 1 - 5% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.

Skin contact

If on skin, rinse well with water.

Eye contact

Immediately flush eye(s) with plenty of water. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.

Ingestion

Keep respiratory tract clear. Rinse mouth with water. If symptoms persist, call a physician.

Medical Treatment

The first aid procedure should be established in consultation with the doctor responsible for industrial medicine.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

High volume water jet

Specific hazards

No information available.

Instructions

Standard procedure for chemical fires. Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Firefighter Protection

Wear self-contained breathing apparatus for firefighting if necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective equipment. Refer to protective measures listed in sections 7 and 8.

Environmental

Prevent product from entering drains. Prevent further leakage or spillage if safe to do so. Local authorities should be advised if significant spillages cannot be contained.

Cleanup methods

Soak up with inert absorbent material.

Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not breathe vapors/dust. Avoid exposure - obtain special instructions before use. Avoid contact with skin and eyes. For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area.

Storage

Keep container tightly closed in a dry and well-ventilated place. Electrical installations / working materials must comply with the technological safety standards.

Hygiene

Smoking, eating and drinking should be prohibited in the application area.

Fire prevention

Normal measures for preventive fire protection.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
liquid
Colour
colorless
Colour Intensity
---
Form
---
Odor
No data available
Odor Threshold
No data available
Ph
7.5 (25 °C)
Melting Point
No data available
Boiling Point
No data available
Flash Point
does not flash
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
No data available
Vapor Density
---
Relative Density
No data available
Bulk Density
---
Density
1.013 g/cm3
Flammability
The product is not flammable.
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
---
Solubility In Water
completely miscible
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
No data available
Kinematic Viscosity
No data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

No dangerous reaction known under conditions of normal use.

Hazardous reactions

No decomposition if stored and applied as directed.

Avoid

No data available

Incompatible

No data available

Decomposition

No decomposition if stored and applied as directed.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.6 Endocrine disrupting properties

12.7 Other adverse effects

Bioaccumulative potential

Partition coefficient: n-octanol/water Remarks: No data available

12.1 Toxicity

Acute aquatic toxicity: This product has no known ecotoxicological effects. Chronic aquatic toxicity: This product has no known ecotoxicological effects. Toxicity Data on Soil: Not expected to adsorb on soil. Other organisms relevant to the environment: No data available

This product has no known ecotoxicological effects.

12.2 Persistence and degradability

No data available

12.1 Toxicity

Toxicity to fish: LC50: > 100 mg/l Exposure time: 96 h ### Ecotoxicology Assessment Acute aquatic toxicity: This product has no known ecotoxicological effects. Chronic aquatic toxicity: This product has no known ecotoxicological effects. Toxicity Data on Soil: Not expected to adsorb on soil.

12.2 Persistence and degradability

No data available

12.3 Bioaccumulative potential

Partition coefficient: n-octanol/water Remarks: No data available

12.4 Mobility in soil

Not expected to adsorb on soil.

Ecotoxicity

Mobility in soil

No data available

Other adverse effects

No data available

Ecotoxicity

Toxicity to fish: LC50: > 100 mg/l Exposure time: 96 h

12.3 Bioaccumulative potential

12.4 Mobility in soil

Not expected to adsorb on soil.

12.5 Results of PBT and vPvB assessment

Ecotoxicity

Components: #-D-Glucopyranoside, #-D-fructofuranosyl: Ecotoxicology Assessment Acute aquatic toxicity : This product has no known ecotoxicological effects. Chronic aquatic toxicity : This product has no known ecotoxicological effects. Toxicity Data on Soil : Not expected to adsorb on soil. Other organisms relevant to the environment : No data available

Mobility in soil

No data available

Other adverse effects

No data available

Ecotoxicity

Toxicity to fish: LC50 (Brachydanio rerio (zebrafish)): > 100 mg/l End point: mortality Exposure time: 96 h Test Type: static test Analytical monitoring: yes Method: OECD Test Guideline 203 GLP: yes Toxicity to daphnia and other aquatic invertebrates: EC50 (Daphnia magna (Water flea)): > 100 mg/l End point: Immobilization Exposure time: 48 h Test Type: static test Analytical monitoring: yes Method: OECD Test Guideline 202 GLP: yes Toxicity to algae/aquatic plants: ErC50 (Pseudokirchneriella subcapitata (green algae)): > 100 mg/l End point: Growth rate Exposure time: 72 h Test Type: static test Analytical monitoring: yes Method: OECD Test Guideline 201 GLP: yes NOEC (Pseudokirchneriella subcapitata (green algae)): > 100 mg/l End point: Growth rate Exposure time: 72 h Test Type: static test Analytical monitoring: yes Method: OECD Test Guideline 201 GLP: yes Toxicity to microorganisms : EC50 (activated sludge): > 1,000 mg/l End point: Respiration inhibition Exposure time: 3 h Test Type: static test Analytical monitoring: no Method: OECD Test Guideline 209 GLP: yes

Toxicity

Other organisms relevant to the environment : No data available

Persistence and degradability

Mobility in soil

Toxicity Data on Soil : Not expected to adsorb on soil.

Persistence and degradability

Components: Biodegradability : aerobic Inoculum: activated sludge, non-adapted Result: Not readily biodegradable. Biodegradation: 0 % Exposure time: 28 d Method: OECD Test Guideline 301D GLP: yes

Bioaccumulative potential

Partition coefficient: n-octanol/water : log Pow: -3.7 (20 °C)

Bioaccumulative potential

Partition coefficient: n-octanol/water : log Pow: < -3.85 (20 °C) Method: OECD Test Guideline 107 GLP: yes

Mobility in soil

No data available

Other adverse effects

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Send to a licensed waste management company. Can be disposed as waste water, when in compliance with local regulations.

Disposal

Do not contaminate ponds, waterways or ditches with chemical or used container.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Elecsys AMH?

The signal word is no signal word.

What is the physical form of Elecsys AMH?

Elecsys AMH is a liquid appearing as liquid with colorless color. It has no data available odor.

What are the hazard statements for Elecsys AMH?

This substance has 1 hazard statement:

  • Not a hazardous substance or mixture.

What is the melting point of Elecsys AMH?

The melting point is No data available and the boiling point is No data available.