Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Elecsys AFP
- Product Code
- 07026706190
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
Roche Diagnostics Limited
national supplier
Charles Avenue, Burgess Hill, RH15 9RY West Sussex, United Kingdom
+44 1444 256000
Emergency Contacts
Roche Diagnostics Ltd.
+44 (0)808 100 1920
Roche Diagnostics Ltd.
1800 409 564
NPIS
+44 344 892 0111
NHS Direct in Wales
111
NHS Direct in Wales
+44 845 4647
NHS 111 in England/NHS 24 in Scotland
111
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 2-methyl-2H-isothiazol-3-one hydrochloride EC: 247-499-3 | 26172-54-3 | 0.0025 - 0.1% | Yes |
| Thermo-BSA-Streptavidin, inact., rec. | --- | 0.1% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.
If on skin, rinse well with water.
Immediately flush eye(s) with plenty of water. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.
Keep respiratory tract clear. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician. Rinse mouth with water.
Medical Treatment
The first aid procedure should be established in consultation with the doctor responsible for industrial medicine.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
High volume water jet
No information available.
Standard procedure for chemical fires.
Firefighter Protection
Wear self-contained breathing apparatus for firefighting if necessary.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment. Refer to protective measures listed in sections 7 and 8.
Prevent product from entering drains. Prevent further leakage or spillage if safe to do so.
Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Keep in suitable, closed containers for disposal.
Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not breathe vapours/dust. Avoid exposure - obtain special instructions before use. Avoid contact with skin and eyes. For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. Dispose of rinse water in accordance with local and national regulations. Persons susceptible to skin sensitisation problems or asthma, allergies, chronic or recurrent respiratory disease should not be employed in any process in which this mixture is being used.
Keep container tightly closed in a dry and well-ventilated place. See label, package insert or internal guidelines
Wash hands before breaks and at the end of workday.
Normal measures for preventive fire protection.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Material : Nitrile rubber, Break through time : > 30 min, Glove thickness : > 0,11 mm. Material : In case of full contact: butyl-rubber, Break through time : > 480 min, Glove thickness : > 0,4 mm. Remarks : The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it. This recommendation is only valid for the product mentioned in the safety data sheet and provided by us and for the application specified by us. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. The suitability for a specific workplace should be discussed with the producers of the protective gloves.
Use eye protection according to EN 166. Tightly fitting safety goggles
Impervious clothing. Choose body protection according to the amount and concentration of the dangerous substance at the work place.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No dangerous reaction known under conditions of normal use.
No decomposition if stored and applied as directed.
No data available
No data available
No data available
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and degradability
12.2 Persistence and degradability
The substance is not readily biodegradable.
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher.
12.7 Other adverse effects
No data available for R1, R2, or SA Coat-Beads.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Send to a licensed waste management company.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Take note of Directive 94/33/EC on the protection of young people at work or stricter national regulations, where applicable.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Elecsys AFP?
The signal word is warning.
What is the physical form of Elecsys AFP?
Elecsys AFP is a liquid with colourless (r1, r2); clear, colourless, red brown (sa coat-beads) color. It has odourless odor.
What is the solubility of Elecsys AFP?
completely miscible (Water)
What are the hazard statements for Elecsys AFP?
This substance has 1 hazard statement:
- H317: May cause an allergic skin reaction.
What is the melting point of Elecsys AFP?
The melting point is No data available and the boiling point is No data available.