NextSDS Logo
Safety Data Sheet EN

INTERGARD 7500 Part B

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
INTERGARD 7500 Part B

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Professional use Industrial use Two component coating for interior and exterior use.

Uses advised against

Consumer use

Manufacturers & Suppliers

I

International Paint Ltd.

manufacturer

Stoneygate Lane, Felling, Gateshead, Tyne and Wear, NE10 0JY, UK

+44 (0)191 469 6111

I

International Färg AB

manufacturer

Holmedalen 3, Aspereds Industriomrade, SE-424 22 Angered, Sweden

+46 (0) 31 928500

Emergency Contacts

National advisory body/Poison Center

+44 (0)344 892 0111

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 3 H226
Skin Corr. Cat. 1C H314
Eye Dam. Cat. 1 H318
Resp. Sens. Cat. 1 H334
Skin Sens. Cat. 1 H317
STOT SE Cat. 3 H335
STOT RE Cat. 2 H373

GHS Pictograms

GHS02 - Flammable

GHS02

GHS05 - Corrosive

GHS05

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H226 Flammable liquid and vapor.
H314 Causes severe skin burns and eye damage.
H317 May cause an allergic skin reaction.
H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled.
H335 May cause respiratory irritation.
H373 May cause damage to organs through prolonged or repeated exposure.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P260 Do not breathe vapor.
P280 Wear protective gloves, protective clothing and eye or face protection.
P284 Wear respiratory protection.
P303 + P361 + P353 + P310 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water. Immediately call a POISON CENTER or doctor.
P304 + P340 + P310 IF INHALED: Remove person to fresh air and keep comfortable for breathing. Immediately call a POISON CENTER or doctor.
P305 + P351 + P338 + P310 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER or doctor.
P333 + P313 If skin irritation or rash occurs: Get medical advice or attention.
P342 + P311 If experiencing respiratory symptoms: Call a POISON CENTER or doctor.
P363 Wash contaminated clothing before reuse.
P403 + P233 Store in a well-ventilated place. Keep container tightly closed.
P403 + P235 Keep cool.
P501 Dispose of contents and container in accordance with all local, regional, national or international regulations.
IF SWALLOWED: Immediately call a POISON CENTER or doctor. Rinse mouth. Do NOT induce vomiting.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Reaction mass of ethylbenzene and xylene EC: 905-588-0 --- 15 - 20% Yes
butan-1-ol EC: 200-751-6 71-36-3 10% Yes
2,4,6-tris (dimethylaminomethyl) phenol EC: 202-013-9 90-72-2 5% Yes
ethylenediamine EC: 203-468-6 107-15-3 1.3% Yes

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment, are PBTs, vPvBs or Substances of equivalent concern, or have been assigned a workplace exposure limit and hence require reporting in this section.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband. In the event of any complaints or symptoms, avoid further exposure.

Symptoms: respiratory tract irritation, coughing, wheezing and breathing difficulties, asthma

Skin contact

Wash with plenty of soap and water. Remove contaminated clothing and shoes. Wash contaminated clothing thoroughly with water before removing it, or wear gloves. Continue to rinse for at least 10 minutes. Chemical burns must be treated promptly by a physician. In the event of any complaints or symptoms, avoid further exposure. Wash clothing before reuse. Clean shoes thoroughly before reuse. Get medical attention if irritation occurs.

Symptoms: pain or irritation, redness, blistering may occur

Eye contact

Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses if easy to do. Chemical burns must be treated promptly by a physician.

Symptoms: pain, watering, redness

Ingestion

Wash out mouth with water. Remove dentures if any. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Chemical burns must be treated promptly by a physician. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: stomach pains

Immediate Medical Attention

Get medical attention immediately. Call a poison center or physician.

Medical Treatment

Chemical burns must be treated promptly by a physician.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use dry chemical, CO₂, water spray (fog) or foam.

Unsuitable media

Do not use water jet.

Specific hazards

Flammable liquid and vapor. Runoff to sewer may create fire or explosion hazard. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Do not breathe vapor or mist. Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put on appropriate personal protective equipment.

Small spill

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Absorb with an inert material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilled product. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations.

Environmental

Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Absorb with an inert material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Materials: inert material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8). Persons with a history of skin sensitization problems or asthma, allergies or chronic or recurrent respiratory disease should not be employed in any process in which this product is used. Do not get in eyes or on skin or clothing. Do not breathe vapor or mist. Do not ingest. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Do not enter storage areas and confined spaces unless adequately ventilated. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use.

Storage

Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Store and use away from heat, sparks, open flame or any other ignition source.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.

Fire prevention

Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use only non-sparking tools. Take precautionary measures against electrostatic discharges.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapor or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. When prolonged or frequently repeated contact may occur, a glove with a protection class of 6 (breakthrough time >480 minutes according to EN374) is recommended. Recommended gloves: Viton ® or Nitrile, thickness ≥ 0.38 mm. When only brief contact is expected, a glove with protection class of 2 or higher (breakthrough time >30 minutes according to EN374) is recommended. Recommended gloves: Nitrile, thickness ≥ 0.12 mm. Gloves should be replaced regularly and if there is any sign of damage to the glove material. The performance or effectiveness of the glove may be reduced by physical/chemical damage and poor maintenance. The user must check that the final choice of type of glove selected for handling this product is the most appropriate and takes into account the particular conditions of use, as included in the user's risk assessment.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: chemical splash goggles and/or face shield. If inhalation hazards exist, a full-face respirator may be required instead.

Respiratory

Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use. Dry sanding, flame cutting and/or welding of the dry paint film will give rise to dust and/or hazardous fumes. Wet sanding/flatting should be used wherever possible. If exposure cannot be avoided by the provision of local exhaust ventilation, suitable respiratory protective equipment should be used. Wear a respirator conforming to EN140 with type A/P2 filter or better.

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Refer to European Standard EN 1149 for further information on material and design requirements and test methods. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Liquid.
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Colorless.
Colour Intensity
---
Form
---
Odor
Amine-like.
Odor Threshold
Not available.
Ph
Not applicable. [DIN EN 1262]
Melting Point
Not available.
Boiling Point
119°C (246.2°F)
Flash Point
Closed cup: 32°C (89.6°F) [Pensky-Martens]
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
octan-1-ol: <7.50064 mm Hg / <1 kPa; Reaction mass of ethylbenzene and xylene: 6.7 mm Hg / 0.89 kPa
Vapor Density
Not available.
Relative Density
---
Bulk Density
---
Density
0.963 g/cm³ [DIN EN ISO 2811-1]
Flammability
---
Upper Explosive Limit
Greatest known range: Upper: 16.6% (ethylenediamine)
Lower Explosive Limit
Greatest known range: Lower: 2.5% (ethylenediamine)
Explosive Limits
---
Auto Ignition Temperature
butan-1-ol: 355°C (671°F); Reaction mass of ethylbenzene and xylene: 432°C (809.6°F)
Decomposition Temperature
Not available.
Solubility
---
Partition Coefficient
Not applicable.
Solubility In Water
Not soluble [OECD (TG 105)]
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Not available.
Kinematic Viscosity
1128 mm²/s [DIN EN ISO 3219] (room temperature); 1086 mm²/s [DIN EN ISO 3219] (40°C)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

Avoid all possible sources of ignition (spark or flame). Do not pressurize, cut, weld, braze, solder, drill, grind or expose containers to heat or sources of ignition.

Incompatible

oxidizing materials

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

There are no data available on the mixture itself. Do not allow to enter drains or watercourses. The mixture has been assessed following the summation method of the CLP Regulation (EC) No 1272/2008 and is not classified as hazardous to the environment, but contains substance(s) hazardous to the environment. See section 3 for details.

12.1 Toxicity

Product/ingredient name: Reaction mass of ethylbenzene and xylene butan-1-ol Result: Acute LC50 13400 μg/l Fresh water, Species: Fish - Pimephales promelas, Exposure: 96 hours Result: Acute EC50 1983 mg/l Fresh water, Species: Daphnia - Daphnia magna, Exposure: 48 hours Result: Acute LC50 2300000 μg/l Marine water, Species: Fish - Alburnus alburnus, Exposure: 96 hours Result: Acute LC50 1910000 μg/l Fresh water, Species: Fish - Pimephales promelas - Juvenile (Fledgling, Hatchling, Weanling), Exposure: 96 hours Result: Acute LC50 1940000 μg/l Fresh water, Species: Fish - Pimephales promelas - Juvenile (Fledgling, Hatchling, Weanling), Exposure: 96 hours

12.1 Toxicity

Product/ingredient name: 2,4,6-tris (dimethylaminomethyl)phenol ethylenediamine Result: Acute LC50 1730000 μg/l Fresh water, Species: Fish - Pimephales promelas, Exposure: 96 hours Result: Acute LC50 175 mg/l, Species: Fish - Cyprinus carpio, Exposure: 96 hours Result: Acute EC50 100000 μg/l Fresh water, Species: Algae - Chlorella pyrenoidosa, Exposure: 96 hours Result: Acute EC50 151000 μg/l Fresh water, Species: Algae - Pseudokirchneriella subcapitata, Exposure: 96 hours Result: Acute LC50 26500 μg/l Fresh water, Species: Daphnia - Daphnia magna, Exposure: 48 hours Result: Acute LC50 46000 μg/l Fresh water, Species: Daphnia - Daphnia magna, Exposure: 48 hours Result: Acute LC50 115.7 mg/l Fresh water, Species: Fish - Pimephales promelas, Exposure: 96 hours Result: Acute LC50 220000 μg/l Fresh water, Species: Fish - Pimephales promelas, Exposure: 96 hours Result: Acute LC50 275000 μg/l Fresh water, Species: Fish - Poecilia reticulata, Exposure: 96 hours Result: Acute LC50 1544700 μg/l Fresh water, Species: Fish - Poecilia reticulata, Exposure: 96 hours Result: Chronic NOEC 0.16 mg/l Fresh water, Species: Daphnia - Daphnia magna, Exposure: 21 days Result: Chronic NOEC 160 μg/l Fresh water, Species: Daphnia - Daphnia magna, Exposure: 21 days

12.2 Persistence and degradability

Conclusion/Summary : Not available.

Not available.

12.3 Bioaccumulative potential

| Product/ingredient name | LogP_{ow} | BCF | Potential | | --- | --- | --- | --- |

12.3 Bioaccumulative potential

| Product/ingredient name | LogP_{ow} | BCF | Potential | | --- | --- | --- | --- | | Reaction mass of ethylbenzene and xylene butan-1-ol | 3.12 | 8.1 to 25.9 | Low | | | 1 | - | Low | | | 0.219 | - | Low |

12.1 Toxicity

12.2 Persistence and degradability

12.3 Bioaccumulative potential

Product/ingredient name: 2,4,6-tris (dimethylaminomethyl) phenol ethylenediamine, LogP_ow: -7.02, BCF: -, Potential: Low

12.4 Mobility in soil

12.5 Results of PBT and vPvB assessment

12.6 Endocrine disrupting properties

12.7 Other adverse effects

12.4 Mobility in soil

Soil/Water partition : Not available. coefficient Mobility : Not available.

12.5 Results of PBT and vPvB assessment

This mixture does not contain any substances that are assessed to be a PBT or a vPvB.

The mixture does not contain any substances assessed as PBT or vPvB.

12.6 Endocrine disrupting properties

Not available.

12.7 Other adverse effects

No known significant effects or critical hazards.

No known significant effects or critical hazards.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

The generation of waste should be avoided or minimized wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction.

Disposal

Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.

Waste Codes

08 01 11* waste paint and varnish containing organic solvents or other hazardous substances EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN3469
Shipping Name
PAINT, FLAMMABLE, CORROSIVE
Transport Class
3 (8)
Packing Group
H
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II, as amended by UK REACH Regulation SI 2019/758

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for INTERGARD 7500 Part B?

The signal word is danger.

What is the physical form of INTERGARD 7500 Part B?

INTERGARD 7500 Part B is a liquid. with colorless. color. It has amine-like. odor.

What is INTERGARD 7500 Part B used for?

Professional use Industrial use Two component coating for interior and exterior use.

What are the hazard statements for INTERGARD 7500 Part B?

This substance has 6 hazard statements:

  • H226: Flammable liquid and vapor.
  • H314: Causes severe skin burns and eye damage.
  • H317: May cause an allergic skin reaction.
  • H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled.
  • H335: May cause respiratory irritation.
  • H373: May cause damage to organs through prolonged or repeated exposure.

What is the melting point of INTERGARD 7500 Part B?

The melting point is Not available. and the boiling point is 119°C (246.2°F).