NextSDS Logo
Safety Data Sheet EN

Alpa Gel Cimco –A

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Alpa Gel Cimco –A
Product Code
151010, 151012, 151014

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Electrical and electronics industry

Manufacturers & Suppliers

C

Cimco Werkzeugfabrik Carl Jul. Müller GmbH & Co. KG

manufacturer

Hohenhagener Straße 1 - 5, D-42855 Remscheid, Germany

+49 (0) 21913718-01

Emergency Contacts

GBK GmbH

+49 (0)6132-84463

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Precautionary Statements

P233 Keep container tightly sealed.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Chemical characterisation: Addition-curing silicon polymer.

Notes

No hazardous constituents according to ordinance (EC) No. 1907/2006

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move the affected person into the fresh air.

Skin contact

In the event of skin contact, mechanically remove with cloth or paper. Immediately wash off with soap and lots of water.

Eye contact

In the event of contact with the eyes, immediately rinse thoroughly with lots of water.

Ingestion

Do not induce vomiting. Rinse mouth with water.

Immediate Medical Attention

In the event of complaints (inhalation), long-term skin irritation (skin), or if symptoms persist (eyes), seek medical assistance/consult a doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam, extinguishing powder, carbon dioxide, water spray

Unsuitable media

Direct water jet

Specific hazards

In case of fire, hazardous decomposition products can occur.

Instructions

To cool sealed containers, use a water spray.

Firefighter Protection

In the presence of combustion or carbonization gases, any firefighting, rescue and clearing up activities should be undertaken only with heavy-duty respiratory protection.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective clothing. Dirty surfaces become extremely slippery.

Environmental

Prevent the product from entering the drain system, water courses, or soil. Pay attention to local official regulations.

Cleanup methods

Clean soiled areas thoroughly.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure adequate ventilation and/or extraction in the work rooms. Do not smoke, eat, drink or sniff while working. Wash hands before breaks and after finishing work.

Storage

Store cool and dry. Protect from frost. Protect from humidity and water.

Hygiene

Do not smoke, eat, drink or sniff while working. Wash hands before breaks and after finishing work.

Fire prevention

Pay attention to usual rules of preventative fire protection. Keep away from ignition sources – Do not smoke.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation and/or extraction in the work rooms.

Hands

Nitrile rubber Protection index class 6 Penetration time: > 480 min Glove thickness: > 0.35 mm The breakthrough times determined according to EN 374 Part III are not tested under practical conditions. We therefore recommend a maximum wearing time of 50% of the breakthrough time. Selection of a suitable glove depends not only on the material but also on other quality features and varies from one manufacturer to another.

Eyes

Safety glasses

Respiratory

If ventilation is inadequate, wear breathing apparatus. Recommended filter type: combination filter A/P

Skin/Body

Protective clothing

Environmental

Prevent the product from entering the drain system, water courses, or soil. Pay attention to local official regulations.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
transparent
Colour Intensity
---
Form
liquid
Odor
odourless
Odor Threshold
---
Ph
---
Melting Point
- na -
Boiling Point
- na -
Flash Point
> 100 °C
Freezing Point
- na -
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
< 100 hPa 20 °C
Vapor Density
---
Relative Density
0.98 g/cm³ 20 °C
Bulk Density
---
Density
---
Flammability
- na -
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
- na -
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
- na -
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable.

Reactivity

No hazards particularly to be mentioned.

Hazardous reactions

No known hazardous reactions if used as intended.

Avoid

Protect from moisture.

Incompatible

Acids, Bases

Decomposition

No decomposition when stored and used as intended.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

| | Value/Evaluation | Species | Method | Note | | --- | --- | --- | --- | --- | | Fish | LC0 200 mg/l (96 h) | Leuciscus idus | | Conclusion by analogy | | Bacteria | EC0 > 10000 mg/l | Pseudomonas putida | | Conclusion by analogy |

12.2 Persistence and degradability

The product floats on water and does not dissolve. It can be mechanically separated in sewage plants.

12.3 Bio accumulation potential

No information is available.

12.4 Mobility in the soil

No information is available.

12.5 Results of PBT and vPvB assessment

PBT: Not applicable vPvB: Not applicable

12.6. Other harmful effects

As the product is not water-soluble, it is not possible to determine the ecological data, e.g. biological capacity for elimination, COD and BOD values by analysis. According to our current knowledge, the product does not contain heavy metals and compounds according to EC directive 2000/60/EC.

The product is not water-soluble, preventing determination of ecological data like COD and BOD. It does not contain heavy metals or compounds listed under EC directive 2000/60/EC.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Dispose of in accordance with local authority regulations.

Waste Codes

* Waste marked with an asterisk (*) are classed as hazardous waste according to Directive 2008/98/EC on hazardous waste. EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The product is classified and marked pursuant to EC Directives or the relevant national laws.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Alpa Gel Cimco –A?

The signal word is no signal word.

What is the physical form of Alpa Gel Cimco –A?

Alpa Gel Cimco –A is a liquid with transparent color. It has odourless odor.

What is Alpa Gel Cimco –A used for?

Electrical and electronics industry

What is the melting point of Alpa Gel Cimco –A?

The melting point is - na - and the boiling point is - na -.