CAT DEO-ULS 10W-30

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
CAT DEO-ULS 10W-30
Product Code
20202040B023, 452615-60

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Diesel engine oil

Uses advised against

None unless specified elsewhere in this SDS.

Manufacturers & Suppliers

ExxonMobil Petroleum & Chemical BV logo

ExxonMobil Petroleum & Chemical BV

global supplier

POLDERDIJKWEG B-2030 Antwerpen Belgium

0800 028 2851

http://www.msds.exxonmobil.com

Emergency Contacts

Emergency Contact

(+44) 870 8200418

24 Hour

National Poison Control Centre

111

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
REACTION MASS OF ISOMERS OF: C7-9 ALKYL 3-(3,5-DI-TERTBUTYL-HYDROXYPHENYL) PROPIONATE EC: 406-040-9 125643-61-0 1 - 5% Yes
C14-16-18 ALKYL PHENOL EC: 931-468-2 --- 0.1 - 1% Yes
Distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 64742-54-7 5 - 10% Yes
Distillates (petroleum), solvent-dewaxed heavy paraffinic EC: 265-169-7 64742-65-0 1 - 5% Yes
Distillates (petroleum), solvent-dewaxed light paraffinic EC: 265-159-2 64742-56-9 1 - 5% Yes
ZINC BIS[O-(6-METHYLHEPTYL)] BIS[O-(SEC-BUTYL)] BIS(DITHIOPHOSPHATE) EC: 298-577-9 93819-94-4 0.1 - 1% Yes

Notes

Note - any classification in brackets is a GHS building block that was not adopted in CLP and therefore is not applicable in the countries which have implemented CLP and is shown for informational purposes only.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove from further exposure. For those providing assistance, avoid exposure to yourself or others. Use adequate respiratory protection. If breathing has stopped, assist ventilation with a mechanical device or use mouth-to-mouth resuscitation.

Symptoms: respiratory irritation, dizziness, nausea, or unconsciousness

Skin contact

Wash contact areas with soap and water.

Symptoms: Local necrosis as evidenced by delayed onset of pain and tissue damage a few hours after injection.

Eye contact

Flush thoroughly with water.

Symptoms: irritation

Ingestion

First aid is normally not required.

Symptoms: discomfort

Immediate Medical Attention

If respiratory irritation, dizziness, nausea, or unconsciousness occurs, seek immediate medical assistance. If product is injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency. If irritation occurs, get medical assistance. Seek medical attention if discomfort occurs.

Medical Treatment

Early surgical treatment within the first few hours may significantly reduce the ultimate extent of injury for high pressure injection injuries.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.

Unsuitable media

Straight streams of water

Instructions

Evacuate area. Prevent run-off from fire control or dilution from entering streams, sewers or drinking water supply. Use water spray to cool fire exposed surfaces and to protect personnel.

Firefighter Protection

Fire-fighters should use standard protective equipment and in enclosed spaces, self-contained breathing apparatus (SCBA).

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

In the event of a spill or accidental release, notify relevant authorities in accordance with all applicable regulations. Avoid contact with spilled material.

Small spill

Normal antistatic work clothes are usually adequate.

Large spill

Full body suit of chemical resistant, antistatic material is recommended.

Environmental

Prevent entry into waterways, sewers, basements or confined areas.

Cleanup methods

Recover by pumping or with suitable absorbent. Remove from the surface by skimming or with suitable absorbents.

Materials: suitable absorbents

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with used product. Prevent small spills and leakage to avoid slip hazard. Use proper bonding and/or earthing procedures.

Storage

The type of container used to store the material may affect static accumulation and dissipation. Do not store in open or unlabelled containers.

Fire prevention

Material can accumulate static charges which may cause an electrical spark (ignition source). When the material is handled in bulk, an electrical spark could ignite any flammable vapors from liquids or residues that may be present (e.g., during switch-loading operations). Use proper bonding and/or earthing procedures. Consult local applicable standards for guidance (American Petroleum Institute 2003, National Fire Protection Agency 77, CENELEC CLC/TR 50404).

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No special requirements under ordinary conditions of use and with adequate ventilation.

Hands

No protection is ordinarily required under normal conditions of use.

Eyes

If contact is likely, safety glasses with side shields are recommended.

Respiratory

If engineering controls do not maintain airborne contaminant concentrations at a level which is adequate to protect worker health, an approved respirator may be appropriate. Respirator selection, use, and maintenance must be in accordance with regulatory requirements, if applicable. Types of respirators to be considered for this material include: No special requirements under ordinary conditions of use and with adequate ventilation. For high airborne concentrations, use an approved supplied-air respirator, operated in positive pressure mode. Supplied air respirators with an escape bottle may be appropriate when oxygen levels are inadequate, gas/vapour warning properties are poor, or if air purifying filter capacity/rating may be exceeded.

Skin/Body

No skin protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid skin contact.

Environmental

Comply with applicable environmental regulations limiting discharge to air, water and soil. Protect the environment by applying appropriate control measures to prevent or limit emissions.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Brown
Colour Intensity
---
Form
---
Odor
Characteristic
Odor Threshold
No data available
Ph
Not technically feasible
Melting Point
Not technically feasible
Boiling Point
> 316°C (600°F) [test method unavailable]
Flash Point
>215°C (419°F) [ASTM D-92]
Freezing Point
No data available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
< 0.013 kPa (0.1 mm Hg) at 20 °C [test method unavailable]
Vapor Density
No data available
Relative Density
0.868 [ASTM D1298]
Bulk Density
---
Density
---
Flammability
Not technically feasible
Upper Explosive Limit
7.0 [test method unavailable]
Lower Explosive Limit
0.9 [test method unavailable]
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
water Negligible
Partition Coefficient
> 3.5 [test method unavailable]
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
81.6 cSt (81.6 mm2/sec) at 40°C | 12 cSt (12 mm2/sec) at 100°C [ASTM D 445]
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Material is stable under normal conditions.

Reactivity

See sub-sections below.

Hazardous reactions

Hazardous polymerization will not occur.

Avoid

Excessive heat. High energy sources of ignition.

Incompatible

Strong oxidisers

Decomposition

Material does not decompose at ambient temperatures.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. TOXICITY

Material -- Not expected to be harmful to aquatic organisms.

Not expected to be harmful to aquatic organisms.

12.2. PERSISTENCE AND DEGRADABILITY

Biodegradation:

12.2. PERSISTENCE AND DEGRADABILITY

Biodegradation: Base oil component -- Expected to be inherently biodegradable

12.3. BIOACCUMULATIVE POTENTIAL

12.3. BIOACCUMULATIVE POTENTIAL

12.3. BIOACCUMULATIVE POTENTIAL

Base oil component -- Has the potential to bioaccumulate, however metabolism or physical properties may reduce the bioconcentration or limit bioavailability.

The substance has the potential to bioaccumulate, but this may be limited by metabolism or physical properties.

12.4. MOBILITY IN SOIL

Base oil component -- Low solubility and floats and is expected to migrate from water to the land. Expected to partition to sediment and wastewater solids.

Low solubility and floats and is expected to migrate from water to the land. Expected to partition to sediment and wastewater solids.

12.5. PERSISTENCE, BIOACCUMULATION AND TOXICITY FOR SUBSTANCE(S)

Material does not meet the Reach Annex XIII criteria for PBT or vPvB.

Material does not meet the Reach Annex XIII criteria for PBT or vPvB.

12.6. OTHER ADVERSE EFFECTS

No adverse effects are expected.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Product is suitable for burning in an enclosed controlled burner for fuel value or disposal by supervised incineration at very high temperatures to prevent formation of undesirable combustion products.

Disposal

Dispose of used oil at designated sites. Minimize skin contact. Do not mix used oils with solvents, brake fluids or coolants.

Waste Codes

13 02 05* EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Applicable UK legislation: REACH, CLP

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for CAT DEO-ULS 10W-30?

The signal word is no signal word.

What is the physical form of CAT DEO-ULS 10W-30?

CAT DEO-ULS 10W-30 is a liquid with brown color. It has characteristic odor.

What is the solubility of CAT DEO-ULS 10W-30?

water Negligible

What is CAT DEO-ULS 10W-30 used for?

Diesel engine oil

What is the melting point of CAT DEO-ULS 10W-30?

The melting point is Not technically feasible and the boiling point is > 316°C (600°F) [test method unavailable].