Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- CAT DEO-ULS 10W-30
- Product Code
- 20202040B023, 452615-00, 97AX89
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Engine oil
Manufacturers & Suppliers
EXXON MOBIL CORPORATION
manufacturer
3225 GALLOWS RD. FAIRFAX, VA. 22037 USA
800-662-4525
http://www.exxon.com
Emergency Contacts
Emergency Contact
609-737-4411
CHEMTREC
800-424-9300
CHEMTREC
703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| ZINC ALKYL DITHIOPHOSPHATE | 113706-15-3 | 0.1 - 1% | Yes |
Notes
All concentrations are percent by weight unless material is a gas. Gas concentrations are in percent by volume.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove from further exposure. Use adequate respiratory protection. If breathing has stopped, assist ventilation with a mechanical device or use mouth-to-mouth resuscitation.
Symptoms: respiratory irritation, dizziness, nausea, or unconsciousness
Wash contact areas with soap and water. If product is injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency.
Symptoms: minimal or absent (initial symptoms from high pressure injection)
Flush thoroughly with water.
Symptoms: irritation
First aid is normally not required.
Symptoms: discomfort
Immediate Medical Attention
Seek immediate medical assistance if respiratory irritation, dizziness, nausea, or unconsciousness occurs. If product is injected into or under the skin, the individual should be evaluated immediately by a physician as a surgical emergency. Seek medical attention if discomfort occurs after ingestion.
Medical Treatment
Early surgical treatment within the first few hours may significantly reduce the ultimate extent of injury (for high pressure injection).
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.
Straight Streams of Water
Evacuate area. Prevent runoff from fire control or dilution from entering streams, sewers, or drinking water supply. Use water spray to cool fire exposed surfaces and to protect personnel.
Firefighter Protection
Firefighters should use standard protective equipment and in enclosed spaces, self-contained breathing apparatus (SCBA).
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Stop leak if you can do it without risk.
Normal antistatic work clothes are usually adequate.
Dike far ahead of liquid spill for later recovery and disposal. Use full body suit of chemical resistant, antistatic material.
Prevent entry into waterways, sewers, basements or confined areas.
Recover by pumping or with suitable absorbent. Remove from the surface by skimming.
Materials: Suitable absorbent
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with used product. Prevent small spills and leakage to avoid slip hazard. Material can accumulate static charges which may cause an electrical spark (ignition source). When the material is handled in bulk, an electrical spark could ignite any flammable vapors from liquids or residues that may be present (e.g., during switch-loading operations). Use proper bonding and/or ground procedures.
Do not store in open or unlabelled containers. The container choice, for example storage vessel, may effect static accumulation and dissipation.
Material can accumulate static charges which may cause an electrical spark (ignition source). Use proper bonding and/or ground procedures.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No special requirements under ordinary conditions of use and with adequate ventilation.
No protection is ordinarily required under normal conditions of use. Any specific glove information provided is based on published literature and glove manufacturer data. Glove suitability and breakthrough time will differ depending on the specific use conditions. Contact the glove manufacturer for specific advice on glove selection and breakthrough times for your use conditions. Inspect and replace worn or damaged gloves.
If contact is likely, safety glasses with side shields are recommended.
If engineering controls do not maintain airborne contaminant concentrations at a level which is adequate to protect worker health, an approved respirator may be appropriate. Respirator selection, use, and maintenance must be in accordance with regulatory requirements, if applicable. For high airborne concentrations, use an approved supplied-air respirator, operated in positive pressure mode. Supplied air respirators with an escape bottle may be appropriate when oxygen levels are inadequate, gas/vapor warning properties are poor, or if air purifying filter capacity/rating may be exceeded.
No skin protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid skin contact.
Comply with applicable environmental regulations limiting discharge to air, water and soil. Protect the environment by applying appropriate control measures to prevent or limit emissions.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Material is stable under normal conditions.
See sub-sections below.
Hazardous polymerization will not occur.
Excessive heat. High energy sources of ignition.
Strong oxidizers
Material does not decompose at ambient temperatures.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
MOBILITY
Low solubility and floats; expected to migrate from water to land and partition to sediment and wastewater solids.
PERSISTENCE AND DEGRADABILITY
BIOACCUMULATION POTENTIAL
Has the potential to bioaccumulate, however metabolism or physical properties may reduce the bioconcentration or limit bioavailability.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Burning in an enclosed controlled burner for fuel value or disposal by supervised incineration at very high temperatures to prevent formation of undesirable combustion products.
Product is suitable for burning in an enclosed controlled burner for fuel value or disposal by supervised incineration at very high temperatures.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This material is not considered hazardous in accordance with OSHA HazCom 2012, 29 CFR 1910.1200.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for CAT DEO-ULS 10W-30?
The signal word is no signal word.
What is the physical form of CAT DEO-ULS 10W-30?
CAT DEO-ULS 10W-30 is a liquid with brown color. It has characteristic odor.
What is CAT DEO-ULS 10W-30 used for?
Engine oil