NextSDS Logo
Safety Data Sheet EN

CAT DEO-ULS 10W-30

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
CAT DEO-ULS 10W-30
Product Code
20202040B023, 452615-00, 97AX89

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Engine oil

Manufacturers & Suppliers

EXXON MOBIL CORPORATION logo

EXXON MOBIL CORPORATION

manufacturer

3225 GALLOWS RD. FAIRFAX, VA. 22037 USA

800-662-4525

http://www.exxon.com

Emergency Contacts

Emergency Contact

609-737-4411

CHEMTREC

800-424-9300

CHEMTREC

703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
ZINC ALKYL DITHIOPHOSPHATE 113706-15-3 0.1 - 1% Yes

Notes

All concentrations are percent by weight unless material is a gas. Gas concentrations are in percent by volume.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove from further exposure. Use adequate respiratory protection. If breathing has stopped, assist ventilation with a mechanical device or use mouth-to-mouth resuscitation.

Symptoms: respiratory irritation, dizziness, nausea, or unconsciousness

Skin contact

Wash contact areas with soap and water. If product is injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency.

Symptoms: minimal or absent (initial symptoms from high pressure injection)

Eye contact

Flush thoroughly with water.

Symptoms: irritation

Ingestion

First aid is normally not required.

Symptoms: discomfort

Immediate Medical Attention

Seek immediate medical assistance if respiratory irritation, dizziness, nausea, or unconsciousness occurs. If product is injected into or under the skin, the individual should be evaluated immediately by a physician as a surgical emergency. Seek medical attention if discomfort occurs after ingestion.

Medical Treatment

Early surgical treatment within the first few hours may significantly reduce the ultimate extent of injury (for high pressure injection).

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.

Unsuitable media

Straight Streams of Water

Instructions

Evacuate area. Prevent runoff from fire control or dilution from entering streams, sewers, or drinking water supply. Use water spray to cool fire exposed surfaces and to protect personnel.

Firefighter Protection

Firefighters should use standard protective equipment and in enclosed spaces, self-contained breathing apparatus (SCBA).

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Stop leak if you can do it without risk.

Small spill

Normal antistatic work clothes are usually adequate.

Large spill

Dike far ahead of liquid spill for later recovery and disposal. Use full body suit of chemical resistant, antistatic material.

Environmental

Prevent entry into waterways, sewers, basements or confined areas.

Cleanup methods

Recover by pumping or with suitable absorbent. Remove from the surface by skimming.

Materials: Suitable absorbent

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with used product. Prevent small spills and leakage to avoid slip hazard. Material can accumulate static charges which may cause an electrical spark (ignition source). When the material is handled in bulk, an electrical spark could ignite any flammable vapors from liquids or residues that may be present (e.g., during switch-loading operations). Use proper bonding and/or ground procedures.

Storage

Do not store in open or unlabelled containers. The container choice, for example storage vessel, may effect static accumulation and dissipation.

Fire prevention

Material can accumulate static charges which may cause an electrical spark (ignition source). Use proper bonding and/or ground procedures.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No special requirements under ordinary conditions of use and with adequate ventilation.

Hands

No protection is ordinarily required under normal conditions of use. Any specific glove information provided is based on published literature and glove manufacturer data. Glove suitability and breakthrough time will differ depending on the specific use conditions. Contact the glove manufacturer for specific advice on glove selection and breakthrough times for your use conditions. Inspect and replace worn or damaged gloves.

Eyes

If contact is likely, safety glasses with side shields are recommended.

Respiratory

If engineering controls do not maintain airborne contaminant concentrations at a level which is adequate to protect worker health, an approved respirator may be appropriate. Respirator selection, use, and maintenance must be in accordance with regulatory requirements, if applicable. For high airborne concentrations, use an approved supplied-air respirator, operated in positive pressure mode. Supplied air respirators with an escape bottle may be appropriate when oxygen levels are inadequate, gas/vapor warning properties are poor, or if air purifying filter capacity/rating may be exceeded.

Skin/Body

No skin protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid skin contact.

Environmental

Comply with applicable environmental regulations limiting discharge to air, water and soil. Protect the environment by applying appropriate control measures to prevent or limit emissions.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Brown
Colour Intensity
---
Form
---
Odor
Characteristic
Odor Threshold
N/D
Ph
---
Melting Point
---
Boiling Point
>316°C (600°F) [Estimated]
Flash Point
215°C (419°F) [ASTM D-92]
Freezing Point
N/D
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
N/D
Vapor Pressure
0.013 kPa (0.1 mm Hg) at 20 °C [Estimated]
Vapor Density
>2 at 101 kPa [Estimated]
Relative Density
0.875 (at 15 °C)
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
7.0
Lower Explosive Limit
0.9
Explosive Limits
---
Auto Ignition Temperature
N/D
Decomposition Temperature
N/D
Solubility
---
Partition Coefficient
> 3.5 [Estimated]
Solubility In Water
Negligible
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
74 cSt (74 mm2/sec) at 40 °C | 11.5 cSt (11.5 mm2/sec) at 100°C
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Material is stable under normal conditions.

Reactivity

See sub-sections below.

Hazardous reactions

Hazardous polymerization will not occur.

Avoid

Excessive heat. High energy sources of ignition.

Incompatible

Strong oxidizers

Decomposition

Material does not decompose at ambient temperatures.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

MOBILITY

Base oil component -- Low solubility and floats and is expected to migrate from water to the land. Expected to partition to sediment and wastewater solids.

Low solubility and floats; expected to migrate from water to land and partition to sediment and wastewater solids.

PERSISTENCE AND DEGRADABILITY

Base oil component -- Expected to be inherently biodegradable

BIOACCUMULATION POTENTIAL

Base oil component -- Has the potential to bioaccumulate, however metabolism or physical properties may reduce the bioconcentration or limit bioavailability.

Has the potential to bioaccumulate, however metabolism or physical properties may reduce the bioconcentration or limit bioavailability.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Burning in an enclosed controlled burner for fuel value or disposal by supervised incineration at very high temperatures to prevent formation of undesirable combustion products.

Disposal

Product is suitable for burning in an enclosed controlled burner for fuel value or disposal by supervised incineration at very high temperatures.

Waste Codes

Not listed The unused product is not specifically listed by the EPA as a hazardous waste (40 CFR, Part 261D). RCRA
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

This material is not considered hazardous in accordance with OSHA HazCom 2012, 29 CFR 1910.1200.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for CAT DEO-ULS 10W-30?

The signal word is no signal word.

What is the physical form of CAT DEO-ULS 10W-30?

CAT DEO-ULS 10W-30 is a liquid with brown color. It has characteristic odor.

What is CAT DEO-ULS 10W-30 used for?

Engine oil