Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- STANDOCRYL VOC XTREME PLUS CLEAR K9720
- Product Form
- Liquid.
- Product Code
- K9720
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Coating component.
Uses advised against
Not for sale to or use by consumers.
Manufacturers & Suppliers
Axalta Coating Systems Germany GmbH & Co. KG
manufacturer
Christbusch 25, DE 42285 Wuppertal
+49 (0)202 529-0
Emergency Contacts
Emergency Contact
+(44)-870-8200418
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| n-butyl acetate EC: 204-658-1 | 123-86-4 | 25 - 50% | Yes |
| 2-Butenedioic acid (2Z)-,1,4-bis (2-ethylhexyl) ester, reaction products with 5-amino-1,3,3-trimethylcyclohexanemethanamine-5isocyanato-1-(isocyanatomethyl)-1,3,3-trimethylcyclohexane-trimethylolpropane triacrylate polymer, di-Bu maleate and di-Et maleate | 3030043-44-5 | 25 - 50% | Yes |
| 2-Butenedioic acid (2Z)-, 1,4-bis (2-ethylhexyl) ester, reaction products with 5-amino-1,3,3-trimethylcyclohexanemethanamine-1,6-hexanediyl diacrylate-5-isocyanato-1-(isocyanatomethyl)-1,3,3-trimethylcyclohexane polymer and di-Bu maleate | 3029721-16-9 | 10 - 25% | Yes |
| 2-methoxy-1-methylethyl acetate EC: 203-603-9 | 108-65-6 | 3% | Yes |
| 2-butoxyethyl acetate EC: 203-933-3 | 112-07-2 | 3% | Yes |
| Reaction mass of bis (1,2,2,6,6-pentamethyl-4-piperidyl) sebacate and methyl 1,2,2,6,6-pentamethyl-4-piperidyl sebacate EC: 915-687-0 | 1065336-91-5 | 1.8% | Yes |
| dibutyl fumarate EC: 203-327-9 | 105-75-9 | 0.47% | Yes |
| 2,6-di-tert-butyl-p-cresol EC: 204-881-4 | 128-37-0 | 0.2% | Yes |
There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment, are PBTs, vPvBs or Substances of equivalent concern, or have been assigned a workplace exposure limit and hence require reporting in this section.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to fresh air and keep at rest in a position comfortable for breathing. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention. If necessary, call a poison center or physician. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Symptoms: Adverse symptoms may include the following: nausea or vomiting, headache, drowsiness/fatigue, dizziness/vertigo, unconsciousness.
Wash skin thoroughly with soap and water or use recognised skin cleanser. Remove contaminated clothing and shoes. Wash contaminated clothing thoroughly with water before removing it, or wear gloves. Continue to rinse for at least 10 minutes. Get medical attention. In the event of any complaints or symptoms, avoid further exposure. Wash clothing before reuse. Clean shoes thoroughly before reuse.
Symptoms: Adverse symptoms may include the following: irritation, redness, dryness, cracking.
Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention.
Wash out mouth with water. Remove dentures if any. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention. If necessary, call a poison center or physician. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Immediate Medical Attention
If unconscious, place in recovery position and get medical attention immediately.
Medical Treatment
Treat symptomatically. No specific treatment.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Recommended: alcohol-resistant foam, CO₂, powders, water spray.
Do not use water jet.
Fire will produce dense black smoke. Exposure to decomposition products may cause a health hazard.
Cool closed containers exposed to fire with water.
Firefighter Protection
Appropriate breathing apparatus may be required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Exclude sources of ignition and ventilate the area. Avoid breathing vapour or mist. Refer to protective measures listed in sections 7 and 8.
Do not allow to enter drains or watercourses.
Preferably clean with a detergent. Avoid using solvents.
Related Products
Similar products with comparable safety profiles
POLYSTYROL 158 K GR 2 CRYSTAL CLEAR 00013
---
ROHPER +LSPR 6PK GLOSS CRYSTAL CLEAR
---
Tectyl™ MULTIPURPOSE TRANSPARENT
UFI: W7KC-9CN7-300C-EJXK
PROMEX Clear
UFI: 7D10-80TR-D00D-EF4D
DOW CORNING(R) 781 ACETOXY SILICONE CLEAR
---
LOCTITE UV8800M 1L EN
---
LOCTITE ECCOBOND EN UV9721 30CC
---
MOLYKOTE® CU-7439 PLUS SPRAY V1
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Prevent the creation of flammable or explosive concentrations of vapours in air and avoid vapour concentrations higher than the occupational exposure limits. In addition, the product should only be used in areas from which all naked lights and other sources of ignition have been excluded. Avoid contact with skin and eyes. Avoid the inhalation of dust, particulates, spray or mist arising from the application of this mixture. Avoid inhalation of dust from sanding. Put on appropriate personal protective equipment. Never use pressure to empty. Container is not a pressure vessel.
Always keep in containers made from the same material as the original one.
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed.
Keep away from heat, sparks and flame. No sparking tools should be used. Vapours are heavier than air and may spread along floors. Vapours may form explosive mixtures with air.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide adequate ventilation. Where reasonably practicable, this should be achieved by the use of local exhaust ventilation and good general extraction. If these are not sufficient to maintain concentrations of particulates and solvent vapours below the OEL, suitable respiratory protection must be worn.
Duration / breakthrough time: <1 hour, Glove material: NBR, nitrile rubber, material thickness as splash protection: at least 0.2 mm, (EN374) Glove material: NBR, nitrile rubber Material thickness for short-term contact: at least 0.5 mm, (EN374). The instructions and information provided by the glove manufacturer on use, storage, maintenance and replacement must be followed. Gloves should be replaced regularly and if there is any sign of damage to the glove material. Always ensure that gloves are free from defects and that they are stored and used correctly. The performance or effectiveness of the glove may be reduced by physical/chemical damage and poor maintenance. Barrier creams may help to protect the exposed areas of the skin but should not be applied once exposure has occurred.
Use safety eyewear designed to protect against splash of liquids.
If workers are exposed to concentrations above the exposure limit, they must use appropriate, certified respirators. Dry sanding, flame cutting and/or welding of the dry paint film will give rise to dust and/or hazardous fumes. Wet sanding/flatting should be used wherever possible. If exposure cannot be avoided by the provision of local exhaust ventilation, suitable respiratory protective equipment should be used.
Personnel should wear antistatic clothing made of natural fibres or of high-temperature-resistant synthetic fibres. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.
Do not allow to enter drains or watercourses.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage and handling conditions (see Section 7).
No specific test data related to reactivity available for this product or its ingredients.
Under normal conditions of storage and use, hazardous reactions will not occur.
When exposed to high temperatures may produce hazardous decomposition products.
oxidising agents, strong alkalis, strong acids
Decomposition products may include the following materials: carbon monoxide, carbon dioxide, smoke, oxides of nitrogen.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.5 Results of PBT and vPvB assessment
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
n-butyl acetate is not classified as PBT or vPvB.
12.5 Results of PBT and vPvB assessment
12.5 Results of PBT and vPvB assessment
The substance is not classified as PBT or vPvB.
12.5 Results of PBT and vPvB assessment
The substance 2-methoxy-1-methylethyl acetate is not considered to be PBT or vPvB.
12.5 Results of PBT and vPvB assessment
2-butoxyethyl acetate is not considered to be PBT or vPvB.
12.5 Results of PBT and vPvB assessment
The substance is not classified as PBT or vPvB, but it is classified as toxic (T).
12.5 Results of PBT and vPvB assessment
Dibutyl fumarate (CAS 105-75-9) is not classified as PBT or vPvB based on the assessment results.
12.5 Results of PBT and vPvB assessment
The substance 2,6-di-tert-butyl-p-cresol is not classified as PBT or vPvB.
12.6 Other adverse effects
No known significant effects or critical hazards.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The generation of waste should be avoided or minimised wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements.
Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1263
- Shipping Name
- PAINT
- Transport Class
- 3
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II, as amended by UK REACH Regulation SI 2019/758
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for STANDOCRYL VOC XTREME PLUS CLEAR K9720?
The signal word is warning.
What is the physical form of STANDOCRYL VOC XTREME PLUS CLEAR K9720?
STANDOCRYL VOC XTREME PLUS CLEAR K9720 is a liquid. with clear. color. It has not available. odor.
What is STANDOCRYL VOC XTREME PLUS CLEAR K9720 used for?
Coating component.
What are the hazard statements for STANDOCRYL VOC XTREME PLUS CLEAR K9720?
This substance has 4 hazard statements:
- H226: Flammable liquid and vapour.
- H317: May cause an allergic skin reaction.
- H336: May cause drowsiness or dizziness.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of STANDOCRYL VOC XTREME PLUS CLEAR K9720?
The melting point is Technically not possible to measure and the boiling point is 125 to 126°C (257 to 258.8°F).