Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
THERMAGUARD CUI 300
Product Code
H16-1

Regulatory Identifiers

CAS Number
N/A

Identified Uses

solvent based, one component siloxane coating

Manufacturers & Suppliers

P

Performance Polymers EMEA B.V.

manufacturer

Snekertrekweg 57, 8912 AA Leewarden - Netherlands

+31(0)208208370

Emergency Contacts

National Poisoning Information Center (NVIC)

+31 (0)30 2748888

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Flam. Liq. Cat. 3 H226
Aquatic Chronic Cat. 2 H411

GHS Pictograms

GHS02 - Flammable

GHS02

GHS09 - Environmental hazard

GHS09

Hazard Statements

H226 Flammable liquid and vapour.
H411 Toxic to aquatic life with long lasting effects.

Precautionary Statements

P210 Keep away from open flames. - No smoking.
P241 Use explosion-proof electrical/ventilating/lighting equipment.
P273 Avoid release to the environment.
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/ shower.
P501 Dispose of contents/container in accordance with local/regional/national/international regulations.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of substances listed below with nonhazardous additions.

Chemical Name CAS Number Concentration Hazardous
xylene EC: 215-535-7 1330-20-7 2.5 - 10% Yes
trizinc bis(orthophosphate) EC: 231-944-3 7779-90-0 2.5 - 10% Yes

Notes

Percentages of the components are expressed as a percentage by weight

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

If symptoms persist consult doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Unsuitable media

Water with full jet

Specific hazards

No further relevant information available.

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear protective equipment. Keep unprotected persons away.

Environmental

Do not allow product to reach sewage system or any water course. Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Absorb with liquid-binding material

Materials: sand, diatomite, acid binders, universal binders, sawdust

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use only in well ventilated areas.

Storage

Store material in original, well-closed packages in a cool, well-ventilated area according to local regulations. Keep container tightly sealed.

Fire prevention

Keep ignition sources away - Do not smoke.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapour or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.

Hands

Chemical resistant gloves (EN 374) Check protective gloves prior to each use for their proper condition. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Fluorocarbon rubber (Viton). Penetration time of glove material: KCL Vitoject 890 breakthrough time > 480 min. thickness: 0,7 mm. at limited contact KCL Camatril 730 breakthrough time 30 min. thickness: 0,4 mm. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed. Not suitable are gloves made of the following materials: All other materials

Eyes

Tightly sealed goggles. Safety glasses according to EN 166 or equivalent

Respiratory

Use suitable respiratory protective device in case of insufficient ventilation. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. If workers are exposed to concentrations above the exposure limit, they must use appropriate, certified respirators. Use a properly fitted, air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary. For organic vapors and solvents type of filter A1 or A2, for dust type of filter P (according to EN 140)

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved before the product is used by a specialist. If there is a risk of ignition by static electricity, anti-static protective clothing should be worn. For the best protection against static discharge, clothing should consist of anti-static overalls, boots and gloves. For further information on materials and design requirements and test methods consult the European standard EN 1149.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
According to product specification
Colour
According to product specification
Colour Intensity
---
Form
Fluid
Odor
Characteristic
Odor Threshold
Not determined.
Ph
Not determined.
Melting Point
Undetermined.
Boiling Point
36 °C
Flash Point
30 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not determined.
Vapor Pressure
Not determined.
Vapor Density
Not determined.
Relative Density
Not determined.
Bulk Density
---
Density
1.97 g/cm³
Flammability
Not applicable.
Upper Explosive Limit
Not determined.
Lower Explosive Limit
Not determined.
Explosive Limits
---
Auto Ignition Temperature
500 °C
Decomposition Temperature
Not determined.
Solubility
---
Partition Coefficient
Not determined.
Solubility In Water
Not miscible or difficult to mix.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
300 mPas
Kinematic Viscosity
> 20,5 mm²/s
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No decomposition if used according to specifications.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

12.1 Toxicity | · Aquatic toxicity: | | | --- | --- | | 1330-20-7 xylene | | | EC50/72 h | 1-10 mg/l (Algae, Growth inhibition test) | | EC50/48 h | 1-10 mg/l (Daphnia magna) | | LC50/96 h | 1-10 mg/l (Oncorhynchus mykiss) |

12.2 Persistence and degradability

12.3 Bioaccumulative potential

12.4 Mobility in soil

12.5 Results of PBT and vPvB assessment

12.6 Endocrine disrupting properties

12.7 Other adverse effects

12.1 Toxicity

7779-90-0 trizinc bis(orthophosphate) EC50/72 h 0.32 mg/l (Algae, Growth inhibition test) EC50/48 h 0.96 mg/l (Daphnia magna) LC50/96 h 0.33-6.06 mg/l (Oncorhynchus mykiss)

12.2 Persistence and degradability

No further relevant information available.

12.3 Bioaccumulative potential

No further relevant information available.

12.1 Toxicity

Ecotoxical effects: Remark: Toxic for fish. Toxic for aquatic organisms

12.4 Mobility in soil

No further relevant information available.

Other adverse effects

General notes: Water hazard class 2 (German Regulation) (Self-assessment): hazardous for water. Do not allow product to reach ground water, water course or sewage system. Danger to drinking water if even small quantities leak into the ground. Also poisonous for fish and plankton in water bodies.

12.5 Results of PBT and vPvB assessment

PBT: Not applicable. vPvB: Not applicable.

The substance is not classified as PBT or vPvB.

12.6 Other adverse effects

No further relevant information available.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Must not be disposed together with household garbage. Do not allow product to reach sewage system.

Disposal

Must not be disposed together with household garbage.

Waste Codes

08 00 00 WASTES FROM THE MANUFACTURE, FORMULATION, SUPPLY AND USE (MFSU) OF COATINGS (PAINTS, VARNISHES AND VITREOUS ENAMELS), ADHESIVES, SEALANTS AND PRINTING INKS EWC
08 01 00 wastes from MFSU and removal of paint and varnish EWC
08 01 11* waste paint and varnish containing organic solvents or other hazardous substances EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1263
Shipping Name
PAINT
Transport Class
3
Packing Group
III
ADR

Warning: Flammable liquids.

IMDG

Warning: Flammable liquids. Stowage Category A

IATA

Warning: Flammable liquids.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for THERMAGUARD CUI 300?

The signal word is warning.

What is the physical form of THERMAGUARD CUI 300?

THERMAGUARD CUI 300 is a liquid appearing as according to product specification with according to product specification color. It has characteristic odor.

What is THERMAGUARD CUI 300 used for?

solvent based, one component siloxane coating

What are the hazard statements for THERMAGUARD CUI 300?

This substance has 2 hazard statements:

  • H226: Flammable liquid and vapour.
  • H411: Toxic to aquatic life with long lasting effects.

What is the melting point of THERMAGUARD CUI 300?

The melting point is Undetermined. and the boiling point is 36 °C.