Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- THERMAGUARD CUI 300
- Product Code
- H16-1
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
solvent based, one component siloxane coating
Manufacturers & Suppliers
Performance Polymers EMEA B.V.
manufacturer
Snekertrekweg 57, 8912 AA Leewarden - Netherlands
+31(0)208208370
Emergency Contacts
National Poisoning Information Center (NVIC)
+31 (0)30 2748888
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS09
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture of substances listed below with nonhazardous additions.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| xylene EC: 215-535-7 | 1330-20-7 | 2.5 - 10% | Yes |
| trizinc bis(orthophosphate) EC: 231-944-3 | 7779-90-0 | 2.5 - 10% | Yes |
Notes
Percentages of the components are expressed as a percentage by weight
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Immediately wash with water and soap and rinse thoroughly.
Rinse opened eye for several minutes under running water.
If symptoms persist consult doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
Water with full jet
No further relevant information available.
Firefighter Protection
No special measures required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear protective equipment. Keep unprotected persons away.
Do not allow product to reach sewage system or any water course. Do not allow to enter sewers/ surface or ground water.
Absorb with liquid-binding material
Materials: sand, diatomite, acid binders, universal binders, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use only in well ventilated areas.
Store material in original, well-closed packages in a cool, well-ventilated area according to local regulations. Keep container tightly sealed.
Keep ignition sources away - Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapour or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.
Chemical resistant gloves (EN 374) Check protective gloves prior to each use for their proper condition. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Fluorocarbon rubber (Viton). Penetration time of glove material: KCL Vitoject 890 breakthrough time > 480 min. thickness: 0,7 mm. at limited contact KCL Camatril 730 breakthrough time 30 min. thickness: 0,4 mm. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed. Not suitable are gloves made of the following materials: All other materials
Tightly sealed goggles. Safety glasses according to EN 166 or equivalent
Use suitable respiratory protective device in case of insufficient ventilation. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. If workers are exposed to concentrations above the exposure limit, they must use appropriate, certified respirators. Use a properly fitted, air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary. For organic vapors and solvents type of filter A1 or A2, for dust type of filter P (according to EN 140)
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved before the product is used by a specialist. If there is a risk of ignition by static electricity, anti-static protective clothing should be worn. For the best protection against static discharge, clothing should consist of anti-static overalls, boots and gloves. For further information on materials and design requirements and test methods consult the European standard EN 1149.
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known.
No decomposition if used according to specifications.
No further relevant information available.
No dangerous decomposition products known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.1 Toxicity
12.4 Mobility in soil
Other adverse effects
12.5 Results of PBT and vPvB assessment
The substance is not classified as PBT or vPvB.
12.6 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Must not be disposed together with household garbage. Do not allow product to reach sewage system.
Must not be disposed together with household garbage.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1263
- Shipping Name
- PAINT
- Transport Class
- 3
- Packing Group
- III
Warning: Flammable liquids.
Warning: Flammable liquids. Stowage Category A
Warning: Flammable liquids.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for THERMAGUARD CUI 300?
The signal word is warning.
What is the physical form of THERMAGUARD CUI 300?
THERMAGUARD CUI 300 is a liquid appearing as according to product specification with according to product specification color. It has characteristic odor.
What is THERMAGUARD CUI 300 used for?
solvent based, one component siloxane coating
What are the hazard statements for THERMAGUARD CUI 300?
This substance has 2 hazard statements:
- H226: Flammable liquid and vapour.
- H411: Toxic to aquatic life with long lasting effects.
What is the melting point of THERMAGUARD CUI 300?
The melting point is Undetermined. and the boiling point is 36 °C.