Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Castolin 1020 XFC
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
brazing rod, brazing wire
Manufacturers & Suppliers
MEC Holding GmbH
manufacturer
Gutenbergstraße 10 D-65825 Kriftel Germany
+49 (0) 6192 4030
Castolin Eutectic Ireland Ltd.
distributor
36 Magna Avenue, Magna Business Park Citywest, Dublin 24, Ireland
+353 (0) 145 158 33
Emergency Contacts
GBK Gefahrgut Buero GmbH, Ingelheim
++49 (0) 6132 / 84463
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Silver EC: 231-131-3 | 7440-22-4 | 10 - 80% | No |
| alkali fluorosilicates(K) EC: 240-896-2 | 16871-90-2 | 5 - 10% | Yes |
| Tin EC: 231-141-8 | 7440-31-5 | 0.1 - 5% | No |
| potassium bifluoride, potassium hydrogen difluoride EC: 232-156-2 | 7789-29-9 | 0.1 - 5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Take affected person into fresh air. Consult a physician if necessary.
In case of contact with skin wash off immediately with plenty of water. Consult a physician if necessary.
In case of contact with eyes rinse thoroughly with plenty of water and seek medical advice.
As soon as possible, take phials of calcium chloride and seek hospital.
Immediate Medical Attention
As soon as possible, take phials of calcium chloride and seek hospital.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Product itself does not burn. Use fire fighting measures that suit the environment and products stored
Firefighter Protection
In case of fire, wear suitable respiratory equipment with positive air supply.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not discharge into the drains or bodies of water.
Shovel into suitable container for disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with eyes, skin or mucous membrane. Do not breathe vapours/dust. Use only in well-ventilated areas. ANSI Z49.1 Safety in Welding, Cutting and allied processes.
Keep container dry and tightly closed.
When using, do not eat, drink or smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide appropriate exhaust ventilation at machinery and at places where dust or smoke can be generated.
Use protective gloves for welders (DIN 4841-4). Use inner-gloves to prevent from allergic reactions due to direct skin contact. Protective gloves resistant to chemicals made off polychloropren, Minimum coat thickness 0.6 mm, Permeation resistance (wear duration) approx. 480 minutes, i.e. protective glove <camapren 722> made by www.kcl.de. Requirements can vary as a function of the use. Therefore it is necessary to adhere additionally to the recommendations given by the manufacturer of protective gloves. This recommendation refers exclusively to the chemical compatibility and the lab test conforming to EN 374 carried out under lab conditions.
Safety goggles with side protection
Use suitable breathing apparatus if there is inadequate ventilation.
Dust resistant protective clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Hydrogen fluoride is liberated on heating at high temperatures in the presence of water vapor.
Strong acids and oxidizing agents
Carbon dioxide, carbon monoxide, boron oxide, boron trifluoride, silver oxides, copper oxides, tin oxides and zinc oxides.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
Ecotoxicity
No data available.
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Where possible recycling is preferred to disposal.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
As an article the product does not need to be labelled in accordance with EC-directives or respective national laws. Although this product does not require a hazard warning label, we recommend that the safety advice should be observed. Danger symbols: Xn - Harmful. Hazardous component(s) to be indicated on label: alkali fluorosilicates(K). R phrases: 20/21/22 Harmful by inhalation, in contact with skin and if swallowed. 36 Irritating to eyes. S phrases: 23 Do not breathe fumes and aerosols. 45 In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible). 51 Use only in well-ventilated areas. 36/37 Wear suitable protective clothing and gloves.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Castolin 1020 XFC?
The signal word is na: r-phrases.
What is the physical form of Castolin 1020 XFC?
Castolin 1020 XFC is a solid with product-specific color. It has odourless odor.
What is Castolin 1020 XFC used for?
brazing rod, brazing wire
What is the melting point of Castolin 1020 XFC?
The melting point is 620 °C and the boiling point is n.a..