Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Ingromat FL
- Product Form
- Mixture
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Cleaning agent
Uses advised against
No additional information available
Manufacturers & Suppliers
Wandres GmbH
manufacturer
Im Gewerbepark, 8, DE- 79252 Stegen, Germany
+49 (0)7661 - 9330 - 0
MPS Machines Ltd
importer
High Barn 3 Cedars Courtyard High Street, LE8 8DN, Fleckney - Leicestershire, UK
+44 (0)116 2401795
Emergency Contacts
National Health Service (NHS)
111
24 h
National Health Service (NHS)
111 or 0845 46 47
Emergency Contact
999
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| reaction mass of 5-chloro-2-methyl-2H-isothiazol-3-one and 2-methyl-2H-isothiazol-3-one (3:1) (Note B) | 55965-84-9 | 0.1% | Yes |
Notes
Note B: Some substances (acids, bases, etc.) are placed on the market in aqueous solutions at various concentrations and, therefore, these solutions require different classification and labelling since the hazards vary at different concentrations. In Part 3 entries with Note B have a general designation of the following type: 'nitric acid ... %'. In this case the supplier must state the percentage concentration of the solution on the label. Unless otherwise stated, it is assumed that the percentage concentration is calculated on a weight/weight basis.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person to fresh air and keep comfortable for breathing.
Wash skin with plenty of water.
Rinse eyes with water as a precaution.
Call a poison center or a doctor if you feel unwell.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Not combustible.
Firefighter Protection
Do not attempt to take action without suitable protective equipment. Self-contained breathing apparatus. Complete protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ventilate spillage area.
Avoid release to the environment.
Take up liquid spill into absorbent material. Take up mechanically (sweeping, shovelling) and collect in suitable container for disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation of the work station. Wear personal protective equipment.
Store in a well-ventilated place. Keep cool.
Do not eat, drink or smoke when using this product. Always wash hands after handling the product.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure good ventilation of the work station.
In case of repeated or prolonged contact wear gloves. ISO 374-1. Nitrile rubber. Choosing the proper glove is a decision that depends not only on the type of material, but also on other quality features, which differ for each manufacturer. Please follow the instructions related to the permeability and the penetration time provided by the manufacturer. Gloves must be replaced after each use and whenever signs of wear or perforation appear
Use splash goggles when eye contact due to splashing is possible. ISO 16321-1
In case of insufficient ventilation, wear suitable respiratory equipment. Breathing apparatus with filter. Particle filter. A-P2. EN 143. Breathing equipment is only to be used in order to handle the residual risk of short term jobs if all other risk minimizing measures have been carried out e.g. retention and/or local exhaust
Wear suitable protective clothing. EN ISO 13688
Avoid release to the environment.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
The product is non-reactive under normal conditions of use, storage and transport.
No dangerous reactions known under normal conditions of use.
No additional information available
No additional information available
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
12.1. Toxicity
12.2. Persistence and degradability
12.2. Persistence and degradability
12.3. Bioaccumulative potential
The product has not been tested.
12.3. Bioaccumulative potential
Based on the n-octanol/water partition coefficient accumulation in organisms is not expected.
12.4. Mobility in soil
The product has not been tested for mobility in soil.
12.4. Mobility in soil
12.5. Results of PBT and vPvB assessment
The product does not contain substances at ≥0.1% that meet the PBT or vPvB criteria of UK REACH regulation, annex XIII.
12.6. Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Disposal must be done according to official regulations. European waste catalogue.
Do not dispose of with domestic waste.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
According to REACH Regulation (EC) No 1907/2006, as retained and amended in UK law.
No additional information available
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Ingromat FL?
The signal word is no signal word.
What is the physical form of Ingromat FL?
Ingromat FL is a liquid with colourless. color. It has odourless. odor.
What is the solubility of Ingromat FL?
Not available
What is Ingromat FL used for?
Cleaning agent
What is the melting point of Ingromat FL?
The melting point is Not applicable and the boiling point is ≈ 100 °C.