NextSDS Logo
Safety Data Sheet EN

Infineum D3503

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Infineum D3503
Product Code
73910

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Additive for heavy duty diesel engine lubricating oil

Uses advised against

This material should not be used for any other purpose than that recommended without expert advice.

Manufacturers & Suppliers

INFINEUM FRANCE S.N.C. logo

INFINEUM FRANCE S.N.C.

manufacturer

Chemin Départemental 54, 13130 BERRE L'ETANG

+33 4 42 74 57 01

http://www.infineum.com

INFINEUM NETHERLANDS B.V. logo

INFINEUM NETHERLANDS B.V.

manufacturer

Herikerbergweg 238 Luna Arena, 1101 CM Amsterdam, The Netherlands

+44 1235 549501

http://www.infineum.com

Emergency Contacts

Emergency Contact

+33-4.4274.4690

Emergency Contact

+49-221-7499 3355

Emergency Contact

+39 019-2150 221

Emergency Contact

+44 1235 549777

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Skin Irrit. Cat. 2 H315
Aquatic Chronic Cat. 3 H412

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H315 Causes skin irritation.
H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P264 Wash skin thoroughly after handling.
P273 Avoid release to the environment.
P280 Wear protective gloves.
P332 + P313 If skin irritation occurs: Get medical advice/ attention.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P501 Dispose of contents/ container to an approved waste disposal plant.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

All concentrations are weight percent units for liquids or volume percent units for gaseous products. Other ingredients are either not hazardous or are below the regulatory disclosure limit.

Chemical Name CAS Number Concentration Hazardous
reaction mass of isomers of: C7-9-alkyl 3-(3,5-di-tert-butyl-4-hydroxyphenyl)propionate EC: 406-040-9 --- 10 - 20% Yes
Zinc bis[O-(6-methylheptyl)] bis[O-(sec-butyl)] bis(dithiophosphate) EC: 298-577-9 --- 6.25 - 10% Yes
bis(nonylphenyl)amine EC: 253-249-4 --- 2.5 - 10% Yes
Molybdenum polysulphide long chain alkyl dithiocarbamate complex EC: 457-320-2 --- 0.25 - 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Consult a physician after significant exposure. If unconscious, place in recovery position and seek medical advice. If breathing has stopped, assist ventilation with a mechanical device. Do not use mouth-to-mouth resuscitation if exposure to hydrogen sulphide is suspected.

Skin contact

Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. If symptoms persist, call a physician. In case of burns apply cold water until pain subsides then seek medical advice.

Symptoms: Dermatitis

Eye contact

Flush eyes with water as a precaution. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists: Get medical advice/ attention.

Ingestion

Clean mouth with water and drink afterwards plenty of water. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. Obtain medical attention.

Immediate Medical Attention

Obtain medical attention.

Medical Treatment

Show this safety data sheet to the doctor in attendance. The first aid procedure should be established in consultation with the doctor responsible for industrial medicine. If a person vomits when lying on his back, place him in the recovery position. Keep patient warm and at rest.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames

Unsuitable media

High volume water jet

Specific hazards

Not classified as flammable or combustible, but will combust if ignited.

Instructions

Collect contaminated fire extinguishing water separately. This must not be discharged into drains. Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus. Exposure to decomposition products may be a hazard to health. Fire-fighters should exercise extreme caution in enclosed spaces due to the possible presence of toxic decomposition and combustion products. Self-contained full-face overpressure breathing apparatus should be used in enclosed spaces. Use standard body protective equipment.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid contact with spilled material. Do not touch or walk through spilled material.

Large spill

Dyke far ahead of liquid spill for later recovery and disposal.

Environmental

Prevent entry into waterways, sewers, basements or confined areas. Do not flush into surface water or sanitary sewer system. Try to prevent the material from entering drains or water courses.

Cleanup methods

Recover by pumping or with suitable absorbent. Seek the advice of a specialist before using dispersants.

Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust).

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with skin and eyes. Smoking, eating and drinking should be prohibited in the application area. Do not reheat above the maximum loading temperature. Extreme caution must be used in tank gauging or similar operations as overheating could lead to accumulation of lethal concentrations of hydrogen sulphide. If decomposition is suspected, or if the product has been overheated, do not open the container, discontinue heating and secure the unit. Initiate emergency procedures, taking all necessary precautions to avoid exposure to noxious or flammable gases (e.g. hydrogen sulphide), such as evacuation of contaminated areas, and use of suitable respiratory protection.

Storage

Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Store below 60 °C.

Hygiene

Smoking, eating and drinking should be prohibited in the application area.

Fire prevention

Normal measures for preventive fire protection.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

See attached ES. No special requirements under ordinary conditions of use and with adequate ventilation. If decomposition is suspected, or if the product has been overheated, do not open the container, discontinue heating and secure the unit. Initiate emergency procedures, taking all necessary precautions to avoid exposure to noxious or flammable gases (e.g. hydrogen sulphide), such as evacuation of contaminated areas, and use of suitable respiratory protection.

Hands

Polyvinyl alcohol or nitrile- butyl-rubber gloves. Before removing gloves clean them with soap and water. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.

Eyes

Eye wash bottle with pure water. Tightly fitting safety goggles. Ensure that eyewash stations and safety showers are close to the workstation location. The applicable European standard can be found in EN 166.

Respiratory

In the case of vapour formation use a respirator with an approved filter. The applicable European standard can be found in EN 140, EN 137, EN 143, EN 14387.

Skin/Body

Impervious clothing. Choose body protection according to the amount and concentration of the dangerous substance at the work place. Long sleeved clothing. The applicable European standard can be found in EN 14605.

Environmental

See attached ES. Prevent entry into waterways, sewers, basements or confined areas. Local authorities should be advised if significant spillages cannot be contained. Do not flush into surface water or sanitary sewer system. Prevent further leakage or spillage if safe to do so. Try to prevent the material from entering drains or water courses. If the product contaminates rivers and lakes or drains inform respective authorities.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
brown
Colour Intensity
---
Form
viscous
Odor
hydrocarbon-like
Odor Threshold
not determined
Ph
Not applicable
Melting Point
not determined
Boiling Point
not determined
Flash Point
184 °C (363 °F)
Freezing Point
not determined
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not applicable
Vapor Pressure
< 0,1 hPa (< 0,1 mmHg) at 20 °C (68 °F) estimated
Vapor Density
not determined
Relative Density
0,961 at 15,6 °C (60,1 °F)
Bulk Density
Not applicable
Density
0,961 g/cm³ at 15 °C (59 °F)
Flammability
not determined
Upper Explosive Limit
not determined
Lower Explosive Limit
not determined
Explosive Limits
---
Auto Ignition Temperature
Not applicable
Decomposition Temperature
not determined
Solubility
---
Partition Coefficient
not determined
Solubility In Water
< 0,0001 g/l estimated
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
183 mm2/s at 100 °C (212 °F); 4467 mm2/s at 40 °C (104 °F)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

No dangerous reaction known under conditions of normal use.

Hazardous reactions

No hazards to be specially mentioned.

Avoid

Excessive heat.

Incompatible

Strong oxidizing agents, water

Decomposition

Hydrogen Sulfide

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

The product should not be allowed to enter drains, water courses or the soil. Do not contaminate ponds, waterways or ditches with chemical or used container. Dispose of contents/ container to an approved waste disposal plant.

Disposal

Disposal recommendations based on material as supplied, Disposal must be in accordance with applicable laws and regulations, and material characteristics at time of disposal

Waste Codes

13 02 XX waste engine, gear and lubricating oils EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Infineum D3503?

The signal word is warning.

What is the physical form of Infineum D3503?

Infineum D3503 is a liquid with brown color. It has hydrocarbon-like odor.

What is Infineum D3503 used for?

Additive for heavy duty diesel engine lubricating oil

What are the hazard statements for Infineum D3503?

This substance has 2 hazard statements:

  • H315: Causes skin irritation.
  • H412: Harmful to aquatic life with long lasting effects.

What is the melting point of Infineum D3503?

The melting point is not determined and the boiling point is not determined.