Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Infineum C9440
- Product Code
- 80025
- Chemical Name
- Not applicable
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Component of lubricant additives
Uses advised against
This material should not be used for any other purpose than that recommended without expert advice.
Manufacturers & Suppliers
INFINEUM UK LIMITED
manufacturer
P. O. Box 1, Milton Hill, Abingdon, Oxfordshire OX13 6BB, United Kingdom
+44 1235 54 9501
http://www.infineum.com
Emergency Contacts
Emergency Contact
04-4274.4690
Emergency Contact
+33-4.4274.4690
Emergency Contact
0221-7499 3355
Emergency Contact
+49-221-7499 3355
Emergency Contact
019-2150 221
Emergency Contact
+39 019-2150 221
Emergency Contact
01235 549777
Emergency Contact
+44 1235 549777
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
No hazardous ingredients.
First Aid Measures
Emergency procedures for chemical exposure incidents
If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.
Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. If symptoms persist, call a physician. In case of burns apply cold water until pain subsides then seek medical advice.
Flush eyes with water as a precaution. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists: Get medical advice/ attention.
Clean mouth with water and drink afterwards plenty of water. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician.
Medical Treatment
No hazards which require special first aid measures. If a person vomits when lying on his back, place him in the recovery position. Keep patient warm and at rest.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames
Do NOT use water jet.
Not classified as flammable or combustible, but will combust if ignited. Carbon monoxide, carbon dioxide and unburned hydrocarbons (smoke).
Standard procedure for chemical fires. Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Firefighter Protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Advice for non-emergency personnel: Avoid contact with spilled material. Do not touch or walk through spilled material.
Wipe up with absorbent material (e.g. cloth, fleece).
Dyke far ahead of liquid spill for later recovery and disposal. Recover by pumping or with suitable absorbent
Prevent entry into waterways, sewers, basements or confined areas. Do not flush into surface water or sanitary sewer system. Prevent further leakage or spillage if safe to do so. Try to prevent the material from entering drains or water courses.
Recover by pumping or with suitable absorbent. Seek the advice of a specialist before using dispersants. Wipe up with absorbent material (e.g. cloth, fleece).
Materials: absorbent material (e.g. cloth, fleece)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
For personal protection see section 8.
Keep container tightly closed in a dry and well-ventilated place.
Smoking, eating and drinking should be prohibited in the application area.
Normal measures for preventive fire protection.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No special requirements under ordinary conditions of use and with adequate ventilation.
Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. When handling hot material, use heat resistant gloves. For prolonged or repeated contact use protective gloves. The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it.
Safety glasses. The applicable European standard can be found in EN 166.
No personal respiratory protective equipment normally required. The applicable European standard can be found in EN 140, EN 137, EN 143, EN 14387.
Long sleeved clothing. The applicable European standard can be found in EN 14605.
Prevent entry into waterways, sewers, basements or confined areas. Do not flush into surface water or sanitary sewer system. Prevent further leakage or spillage if safe to do so. Try to prevent the material from entering drains or water courses. If the product contaminates rivers and lakes or drains inform respective authorities.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
No dangerous reaction known under conditions of normal use.
No hazards to be specially mentioned.
Excessive heat.
Strong oxidizing agents
No decomposition if used as directed.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.1 Toxicity
No data is available on the product itself regarding acute toxicity to fish, daphnia, or algae. The product has no known ecotoxicological effects.
12.2 Persistence and degradability
No data is available on the product itself regarding biodegradability.
12.3 Bioaccumulative potential
12.4 Mobility in soil
No data is available on the product itself.
12.5 Results of PBT and vPvB assessment
The substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
12.6 Endocrine Disrupting Properties
No data is available on the product itself regarding endocrine disrupting properties.
12.7 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of contents/ container to an approved waste disposal plant.
Disposal must be in accordance with applicable laws and regulations, and material characteristics at time of disposal
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
A Chemical Safety Assessment is not required for this substance/mixture
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Infineum C9440?
The signal word is no signal word.
What is the physical form of Infineum C9440?
Infineum C9440 is a liquid with light yellow color. It has mild odor.
What is Infineum C9440 used for?
Component of lubricant additives
What is the melting point of Infineum C9440?
The melting point is not determined and the boiling point is not determined.