NextSDS Logo
SI

SIGMACOVER 522 BASE GREEN 9048

WARNING Liquide SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
SIGMACOVER 522 BASE GREEN 9048
Product Code
000001100001

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Applications professionnelles, Utilis par pulvrisation. Revtement.
Uses Advised Against
Le produit n'est pas destin, tiquet ou emball pour l'usage du consommateur.

Overview

SIGMACOVER 522 BASE GREEN 9048 commonly used applications professionnelles, utilis par pulvrisation. revtement..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Attention)

Hazard Classifications

Flam. Liq. Category 3 H226
Skin Irrit. Category 2 H315
Eye Irrit. Category 2 H319
Skin Sens. Category 1 H317
Aquatic Chronic Category 2 H411

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

  • P210: Tenir lcart de la chaleur, des surfaces chaudes, des tincelles, des flammes nues et de toute autre source dinflammation. Ne pas fumer.
  • P261: viter de respirer les vapeurs.
  • P273: viter le rejet dans lenvironnement.
  • P280: Porter des gants de protection. Porter un quipement de protection des yeux ou du visage.
  • P391: Recueillir le produit rpandu.
  • P501: liminer le contenu et le rcipient en conformit avec toutes rglementations locales, rgionales, nationales, et internationales.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

PPG Coatings Belgium BV/SRL

undefined

πŸ“

Tweemontstraat 104 B-2100 Deurne Belgium

🌍

BE

πŸ“ž

+32-33606311

πŸ“ 

+32-33606435

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Centre Anti-Poisons/Antigifcentrum

πŸ“ž

+ 32 70 245 245

🌍

BE

Fournisseur

πŸ“ž

+31 20 4075210

🌍

NL

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Ce mlange contient 1% de dioxyde de titane. La classification annexe VI de dioxyde de titane ne s'applique pas ce mlange selon la note 10.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
résines époxydiques (700<MW<=1100) 25036-25-3 10-25% ⚠️ Hazardous
XYLNE
EC: 215-535-7
1330-20-7 10-17% ⚠️ Hazardous
ETHYLBENZOL
EC: 202-849-4
100-41-4 1-5% ⚠️ Hazardous
2-METHYL-1-PROPANOL
EC: 201-148-0
78-83-1 0.3-2.5% ⚠️ Hazardous
4-nonylphΓ©nol, ramifiΓ©
EC: 284-325-5
84852-15-3 1% ⚠️ Hazardous
tolune N/A 0.3% ⚠️ Hazardous
Nonylphenols
EC: 203-625-9
108-88-3 0.077% ⚠️ Hazardous

Composition Notes

Dans l'tat actuel des connaissances du fournisseur et dans les concentrations d'application, aucun autre ingrdient prsent n'est class comme dangereux pour la sant ou l'environnement, ni comme PTB ou vPvB, ni comme substance de degr de proccupation quivalent, ni soumi une limite d'exposition professionnelle et donc ncessiterait de figurer dans cette section. Les limites d'exposition professionnelle, quand elles sont disponibles, sont numres la section 8.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Emmener l'air frais. Garder la personne au chaud et au repos. S'il ne respire pas, en cas de respiration irrgulire ou d'arrt respiratoire, que le personnel qualifi pratique la respiration artificielle ou administre de l'oxygne.

Symptoms:

Aucun effet important ou danger critique connu. Aucune donne spcifique.

πŸ–οΈ Skin Contact

Retirer les vtements et les chaussures contamins. Laver soigneusement la peau au savon et l'eau ou utiliser un nettoyant cutan reconnu. NE PAS UTILISER de solvants ni de diluants.

Symptoms:

Provoque une irritation cutane. Dgraisse la peau. Peut provoquer une allergie cutane. Les symptmes nfastes peuvent ventuellement comprendre ce qui suit: irritation, rougeur, scheresse, gerure.

πŸ‘οΈ Eye Contact

Enlever les lentilles de contact. Laver abondamment avec de l'eau douce et propre en maintenant les paupires cartes pendant au moins 10 minutes et faire appel immdiatement un mdecin.

Symptoms:

Provoque une svre irritation des yeux. Les symptmes nfastes peuvent ventuellement comprendre ce qui suit: douleur ou irritation, larmoiement, rougeur.

🍽️ Ingestion/Swallowing

En cas d'ingestion, consulter immdiatement un mdecin et lui montrer l'emballage ou l'tiquette. Garder la personne au chaud et au repos. NE PAS faire vomir.

Symptoms:

Aucun effet important ou danger critique connu. Aucune donne spcifique.

🚨 Immediate Medical Attention Required

Contacter immdiatement un spcialiste pour le traitement des intoxications, si de grandes quantits ont t ingres ou inhales.

Medical Treatment

Traitement symptomatique requis.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

πŸ“Š Metal Corrosion
Not available
πŸ“Š Explosive Limits
Not available
βš–οΈ Density
Not available
🎨 Colour
Vert
πŸ“Š Dynamic Viscosity
Not available
πŸ’¨ Boiling Point
>37.78C
Critical Property
🧊 Melting Point
Not available
πŸ“Š State Under Standard Conditions
Not available
πŸ“Š Cloud Point
Not available
πŸ“Š Freezing Point
Not available
πŸ‘οΈ Appearance
Not available
πŸ“Š Upper Explosive Limit
10.9%
πŸ’¨ Evaporation Rate
Plus haute valeur connue: 0.84 (thylbenzne) Moyenne pondre: 0.77compar actate de butyle
πŸ”₯ Flammability
Non disponible.
πŸ“Š Solubility In Fat
Not available
πŸ”₯ Flash Point
26C
Critical Property
πŸ“Š Molecular Weight
Not available
πŸ“Š Properties Status
Not available
πŸ’¨ Vapor Pressure
2-mthylpropane-1-ol <12 mm Hg <1.6 kPa
πŸ’§ Solubility
Non soluble dans l'eau froide
πŸ“Š Physical State Data
liquid
πŸ“Š Relative Evaporation Rate
Not available
πŸ“Š Softening Point
Not available
πŸ“Š Vapor Density
Moyenne pondre: 3.57 (Air = 1)
πŸ“Š Odor Threshold
Non disponible
πŸ“Š Decomposition Temperature
Stable dans les conditions de stockage et de manipulation recommandes (voir Section 7).
πŸ‘ƒ Odor
Aromatique
πŸ“Š Solidification Point
-95.39C (-139.7F)
πŸ“Š Partition Coefficient
Non applicable.
πŸ“Š Kinematic Viscosity
>21 mm2/s
πŸ“Š Solubility In Water
Non soluble
πŸ“Š Bulk Density
Not available
πŸ§ͺ Ph
Non applicable. insoluble(s) dans l'eau.
πŸ“Š Lower Explosive Limit
1.7%
πŸ“Š Form
Not available
πŸ“Š Crystallisation Point
Not available
πŸ“Š Colour Intensity
Not available
πŸ“Š Relative Density
1.9
πŸ§ͺ Physical State
Liquide
Critical Property
πŸ“Š Voc Content
Not available
πŸ“Š Auto Ignition Temperature
415C (779F)

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Utiliser uniquement dans un environnement bien ar. Utiliser des enceintes fermes, une ventilation par aspiration la source, ou d'autres systmes de contrle automatique intgrs afin de maintenir le seuil d'exposition du technicien aux contaminants en suspension dans l'air infrieur aux limites recommandes ou lgales. Les moyens de contrle automatiques intgrs devront permettre de maintenir les concentrations en gaz, en vapeur ou en poussire en dessous de tout seuil d'explosion. Utiliser un quipement de ventilation antidflagrant.

🧀 Hand Protection

Le port de gants impermables et rsistants aux produits chimiques conformes une norme approuve, est obligatoire en tout temps lors de la manutention de produits chimiques si une valuation des risques le prconise. En prenant en compte les paramtres indiqus par le fabricant de gants, vrifier pendant l'utilisation que les gants conservent leurs proprits protectrices. Il est not que le temps de claquage des gants peut diffrer d'un fabricant l'autre. En cas de mlanges constitus de plusieurs substances, il est impossible d'estimer de faon prcise le dlai de scurit des gants. Gants recommands sont bas sur le solvant le plus commun dans ce produit. Pour un contact prolong ou frquement rpt, des gants de classe de protection 6 (temps de rupture suprieur 480 minutes selon la norme EM 374) sont recommands. Pour un contact bref, des gants de classe de protection 2 ou classe suprieure (temps de rupture suprieur 30 minutes selon la norme EN 374) sont recommands. L'utilisateur doit vrifier que les types de gants qu'il choisit de porter pour la manipulation de ce produit est le plus appropri et prend en compte les conditions d'utilisation particulires, conformment aux indications stipules dans l'valuation des risques de l'utilisateur. Gants: caoutchouc butyle

πŸ‘οΈ Eye Protection

Lunettes anti-claboussures. Utiliser une protection oculaire homologue EN 166.

😷 Respiratory Protection

Le choix de l'appareil de protection respiratoire doit tre fond sur les niveaux d'expositions prvus ou connus, les dangers du produit et les limites d'utilisation sans danger de l'appareil de protection respiratoire retenu. Les ouvriers exposs des concentrations suprieures la limite d'exposition doivent porter des appareils de protection respiratoire appropris et homologus. Porter un appareil de protection respiratoire muni d'un purificateur d'air ou adduction d' air, parfaitement ajust et conforme une norme en vigueur si une valuation du risque indique que cela est ncessaire. Porter un masque respiratoire conformment la norme EN140. Type de filtre : filtre de vapeurs organiques (Type A) et particules P3

🦺 Skin/Body Protection

L'quipement de protection personnel pour le corps devra tre choisi en fonction de la tche raliser ainsi que des risques encourus, et il est recommand de le faire valider par un spcialiste avant de procder la manipulation du produit. En cas de risque d'inflammation li l'lectricit statique, porter des vtements de protection antistatiques. Pour une protection maximale contre les dcharges d'lectricit statique, les vtements doivent inclure une combinaison, des chaussures et des gants antistatiques. Pour plus d'informations sur les exigences et les mthodes d'essais des matires et des modles, consulter la norme europenne EN 1149. Des chaussures adquates et toutes mesures de protection corporelle devraient tre dtermines en fonction de l'opration effectue et des risques impliqus, et devraient tre approuves par un spcialiste avant toute manipulation de ce produit.

🌍 Environmental Exposure Controls

Il importe de tester les missions provenant des systmes de ventilation ou du matriel de fabrication pour vous assurer qu'elles sont conformes aux exigences de la lgislation sur la protection de l'environnement. Dans certains cas, il sera ncessaire d'quiper le matriel de fabrication d'un purateur de gaz ou d'un filtre ou de le modifier techniquement afin de rduire les missions des niveaux acceptables.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

UN1263

⚠️ Transport Hazard Class

3

πŸ“‹ Packing Group

III

πŸš› ADR Transport Precautions

toujours transporter dans des conditionnements qui sont corrects et scuriss. S'assurer que les personnes transportant le produit connaissent les mesures prendre en cas d'accident ou de dversement accidentel.

🚒 IMDG Maritime Transport Precautions

toujours transporter dans des conditionnements qui sont corrects et scuriss. S'assurer que les personnes transportant le produit connaissent les mesures prendre en cas d'accident ou de dversement accidentel.

✈️ IATA Air Transport Precautions

toujours transporter dans des conditionnements qui sont corrects et scuriss. S'assurer que les personnes transportant le produit connaissent les mesures prendre en cas d'accident ou de dversement accidentel.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for SIGMACOVER 522 BASE GREEN 9048?

The signal word for this substance is "warning".

What is the physical form of SIGMACOVER 522 BASE GREEN 9048?

SIGMACOVER 522 BASE GREEN 9048 is a liquide with vert color. It has aromatique odor.

What is the solubility of SIGMACOVER 522 BASE GREEN 9048?

Non soluble dans l'eau froide

What is SIGMACOVER 522 BASE GREEN 9048 used for?

Applications professionnelles, Utilis par pulvrisation. Revtement.