NextSDS Logo
SC

SCL-500

WARNING liquide SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
SCL-500
Product Code
SCL-500

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
ED40-R0NP-U009-D21N

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
Industrielles, Professionnelles, Consommateurs. Liquide neutralisant l'lectrolyte de dcapage soudure et dgraissant de surface acier inoxydable.
Uses Advised Against
Ne pas utiliser des fins autres que celles numres.

Overview

SCL-500 commonly used industrielles, professionnelles, consommateurs. liquide neutralisant l'lectrolyte de dcapage soudure et dgraissant de surface acier inoxydable..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Attention)

Hazard Classifications

Eye Irrit. Category 2 H319
Skin Irrit. Category 2 H315

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H315: Provoque une irritation cutane.
  • H319: Provoque une svre irritation des yeux.

Precautionary Statements

  • P280: Porter des gants de protection / des vtements de protection / un quipement de protection des yeux / du visage.
  • P337 + P313: Si l`irritation oculaire persiste: consulter un mdecin.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Core Industrial B.V. company logo - Safety Data Sheet supplier organization

Core Industrial B.V.

manufacturer

📍

Oud Camp 22, 3155 DL Maasland

🌍

NL

📞

+31886972520

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

📞

+31886972520

🌍

NL

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mlanges

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
BUTYLGLYKOL
EC: 203-905-0
111-76-2 1-3% ⚠️ Hazardous
NATRIUMHYDROXID
EC: 215-185-5
1310-73-2 0.1-1% ⚠️ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Conduire immdiatement la personne l'air libre. En cas de difficults respiratoires, appeler aussitt un mdecin.

🖐️ Skin Contact

Retirer les vtements contamins. Laver abondamment l'eau. Si l'irritation persiste, consulter un mdecin. Laver les vtements contamins avant de les rutiliser.

👁️ Eye Contact

Retirer les ventuels verres de contact. Se laver immdiatement et abondamment l`eau pendant au moins 15 minutes en ouvrant bien les paupires. Consulter un mdecin si le problme persiste.

🍽️ Ingestion/Swallowing

Consulter aussitt un mdecin. Provoquer les vomissements uniquement sur instructions du mdecin. Ne rien administrer par voie orale si la personne a perdu connaissance.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

🧪 Physical State
liquide
Critical Property
📊 Physical State Data
liquid
📊 State Under Standard Conditions
Not available
👁️ Appearance
Not available
🎨 Colour
incolore
📊 Colour Intensity
Not available
📊 Form
Not available
👃 Odor
typique
📊 Odor Threshold
Pas disponible
🧪 Ph
10.9 (sol.1%)
🧊 Melting Point
Pas disponible
Critical Property
💨 Boiling Point
100 C
Critical Property
🔥 Flash Point
ininflammable
Critical Property
📊 Freezing Point
Pas disponible
📊 Softening Point
Not available
📊 Solidification Point
Not available
📊 Cloud Point
Not available
📊 Crystallisation Point
Not available
📊 Relative Evaporation Rate
Not available
💨 Evaporation Rate
Pas disponible
💨 Vapor Pressure
Pas disponible
📊 Vapor Density
Pas disponible
📊 Relative Density
1 kg/dm3
📊 Bulk Density
Not available
⚖️ Density
Not available
🔥 Flammability
Pas disponible
📊 Upper Explosive Limit
Pas disponible
📊 Lower Explosive Limit
Pas disponible
📊 Explosive Limits
Not available
📊 Auto Ignition Temperature
Pas disponible
📊 Decomposition Temperature
Pas disponible
💧 Solubility
compltement soluble dans l'eau
📊 Partition Coefficient
Pas disponible
📊 Solubility In Water
compltement soluble dans l'eau
📊 Solubility In Fat
Not available
📊 Molecular Weight
Not available
📊 Voc Content
5.00 %
📊 Metal Corrosion
Not available
📊 Dynamic Viscosity
Not available
📊 Kinematic Viscosity
Not available
📊 Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Le recours à des mesures techniques appropriées devant toujours avoir la priorité sur l'utilisation des dispositifs de protection individuelle, veiller à assurer une bonne ventilation sur le lieu de travail par le biais d'un système d'aspiration approprié.

🧤 Hand Protection

Se protéger les mains à l'aide de gants de travail de catégorie III (réf. norme EN 374). Pour le choix du matériau des gants de travail, il est nécessaire de tenir compte des facteurs suivants: compatibilité, dégradation, temps de rupture et perméabilité équivalentes. Dans le cas de préparations, la résistance des gants de travail doit être testée avant l'utilisation dans la mesure où elle ne peut être établie a priori. Le temps d'usure des gants dépend de la durée de l'exposition.

👁️ Eye Protection

Il est recommandé de porter des lunettes de protection hermétiques (réf. norme EN 166).

😷 Respiratory Protection

En cas de dépassement de la valeur limite (ex. TLV-TWA) de la substance ou d'une ou de plusieurs des substances présentes dans le produit, Il est recommandé de faire usage d'un masque doté de filtre de type A dont la classe (1, 2 ou 3) devra être choisie en fonction de la concentration limite d'utilisation. (réf. norme EN 14387). En présence de gaz ou de vapeurs de nature différente et/ou de gaz ou de vapeurs contenant des particules (aérosol, fumées, brumes, etc.), il est nécessaire de prévoir des filtres de type combiné. L'utilisation de moyens de protection des voies respiratoires est nécessaire dans le cas où les mesures techniques adoptées ne seraient pas suffisantes pour limiter l'exposition du personnel aux valeurs de seuil prises en compte. La protection offerte par les masques est toutefois limitée. Dans le cas où la substance en question serait inodore ou dans le cas où le seuil olfactif serait supérieur au TLV-TWA correspondant et en cas d'urgence, faire usage d'un respirateur autonome à air comprimé à circuit ouvert (réf. norme EN 137) ou d'un respirateur à prise d'air externe (réf. norme EN 138). Pour choisir correctement le dispositif de protection des voies respiratoires, faire référence à la norme EN 529.

🦺 Skin/Body Protection

Utiliser des vêtements de travail à manches longues et des chaussures de sécurité à usage professionnel de catégorie II (réf. Règlement 2016/425 et norme EN ISO 20344). Se laver à l'eau et au savon après avoir ôté les vêtements de protection.

🌍 Environmental Exposure Controls

Les émissions de processus de production, y compris celles d'appareillages de ventilation, doivent être contrôlées pour garantir le respect de la réglementation en matière de protection de l'environnement.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for SCL-500?

The signal word for this substance is "warning".

What is the physical form of SCL-500?

SCL-500 is a liquide with incolore color. It has typique odor.

What is the solubility of SCL-500?

compltement soluble dans l'eau

What is SCL-500 used for?

Industrielles, Professionnelles, Consommateurs. Liquide neutralisant l'lectrolyte de dcapage soudure et dgraissant de surface acier inoxydable.

What are the hazard statements for SCL-500?

This substance has 2 hazard statements: H315: Provoque une irritation cutane. H319: Provoque une svre irritation des yeux.

What is the melting point of SCL-500?

The melting point is Pas disponible and the boiling point is 100 C.