NextSDS Logo
HA

HAKU GB 1250

WARNING Liquide SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
HAKU GB 1250

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Catégories de produits [PC] PC9 - Revêtements et couleurs, matériels de remplissage, enduits, diluants PC35 - Produits de lavage et de nettoyage (y compris produits à base de solvants)

Overview

HAKU GB 1250 is a clair substance commonly used catégories de produits [pc] pc9 - revêtements et couleurs, matériels de remplissage, enduits, diluants pc35 - produits de lavage et de nettoyage (y compris produits à base de solvants).

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Attention)

Hazard Classifications

Flam. Liq. Category 3 H226

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H226: Liquide et vapeurs inflammables.

Precautionary Statements

  • P210: Tenir à l'écart de la chaleur, des surfaces chaudes, des étincelles, des flammes nues et de toute autre source d'inflammation. Ne pas fumer.
  • P233: Maintenir le récipient fermé de manière étanche.
  • P303 + P361 + P353: EN CAS DE CONTACT AVEC LA PEAU (ou les cheveux): Enlever immédiatement tous les vêtements contaminés. Rincer la peau à l’eau/Se doucher.
  • P370 + P378: En cas d'incendie: utiliser du sable sec, dioxyde de carbone, poudre d'extinction ou agent de mousse anti-alcool pour l'extinction.
  • P403 + P235: Stocker dans un endroit bien ventilé. Tenir au frais.
  • P501: Éliminer le contenu / récipient dans une société de traitement des déchets agréée.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Kluthe Benelux B.V.

distributor

Produktieweg 8 NL 2404 CC ALPHEN AAN DEN RIJN

NL

+31 (0)172 - 516000

+31 (0)172 - 439494

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Nationaal Vergiftigingen Informatie Centrum NVIC

+ 31 30 274 88 88

NL

Uitsluitend bereikbaar voor een behandelend arts in geval van een accidentele vergiftiging

Antigifcentrum

+ 32 70 245 245

BE

een arts beantwoordt uw oproep

Centre Anti-poison

+ 32 70 245 245

BE

un médecin répondra à votre appel

Antigifcentrum

+49 30 450 653565

DE

(Duitsland - Berlin)

Swedish Poisons Information Center

112

SE

begär Giftinformationscentralen

Ricardo-AEA

+44 (0)870 190 6777

GB

(UK)

Poison Information Center Denmark

+45 82 12 12 12

DK

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
ACÉTATE DE 2-MÉTHOXY-1-MÉTHYLÉTHYLE
EC: 203-603-9
108-65-6 50-100% Hazardous
ACÉTATE DE 2-MÉTHOXYPROPYLE
EC: 274-724-2
70657-70-4 0.3% Hazardous

Composition Notes

Texte des phrases H- et EUH: voir section 16.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Transporter la victime à l'air libre, la protéger par une couverture et la maintenir immobile. En cas d'irritation des voies respiratoires, consulter un médecin.

Symptoms:

irritation des voies respiratoires

Skin Contact

Changer les vêtements souillés ou mouillés. Après contact avec la peau, se laver immédiatement et abondamment avec eau et savon. Appliquer une crème grasse.

Eye Contact

en cas de contact avec les yeux, rincer un moment avec de l'eau en gardant la paupière ouverte et consulter immédiatement un ophtamologiste.

Ingestion/Swallowing

Après ingestion, rincer la bouche de la victime consciente à l'eau et appeler immédiatement le médecin. Faire boire de l'eau en grandes quantités par petites gorgées (effet de dilution).

Immediate Medical Attention Required

Aucune

Medical Treatment

Aucune

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Cloud Point
Not available
Bulk Density
Not available
Vapor Pressure
0,39 kPa
Evaporation Rate
Not available
Solubility
Not available
Explosive Limits
Not available
Molecular Weight
Not available
Freezing Point
Not available
Softening Point
Not available
Upper Explosive Limit
< 7 Vol-%
Solubility In Water
< 23 Pds %
Physical State
Liquide
Critical Property
Vapor Density
Not available
Flash Point
45 °C
Critical Property
Form
Not available
Partition Coefficient
Not available
Lower Explosive Limit
> 1,5 Vol-%
Crystallisation Point
Not available
Density
0,964 - 0,97 g/cm[3]
Critical Property
Relative Density
Not available
Appearance
Clair
Odor
Caractéristique
Solubility In Fat
Not available
Relative Evaporation Rate
Not available
Flammability
Not available
Colour
Incolore
State Under Standard Conditions
Liquide
Colour Intensity
Not available
Kinematic Viscosity
Not available
Ph
Not available
Voc Content
Not available
Decomposition Temperature
Not available
Dynamic Viscosity
Not available
Auto Ignition Temperature
315 °C
Properties Status
Not available
Boiling Point
143 - 148 °C
Critical Property
Odor Threshold
Not available
Physical State Data
liquid
Metal Corrosion
Not available
Solidification Point
Not available
Melting Point
< -30 °C
Critical Property
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Mesures techniques d'aspiration ou de ventilation.

Hand Protection

ll n'existe pas de gant, quelque soit sa (ou ses) composition(s), qui donne une résistance illimitée à tout produit chimique (qu'il soit pur ou en mélange). Le temps de perméation doit être supérieure à la durée d'utilisation finale du produit. Suivre les instructions du fabricant de gants relatives à l'utilisation, au stockage, à l'entretien et au remplacement des gants. Les gants doivent être remplacés régulièrement, ainsi qu'en cas de signe de dommages de la matière constitutive du gant. Toujours s'assurer que les gants sont exempts de défauts et qu'ils sont stockés et utilisés correctement. Les performances ou l'efficacité des gants peuvent être réduites par des dommages physiques / chimiques et un mauvais entretien. Des crèmes protectrices peuvent être utilisées pour les parties exposées de la peau ; elles ne devraient toutefois pas être appliquées après le début de l'exposition. Matériau approprié : Caoutchouc butyle Temps de pénétration (durée maximale de port) : 480 min Epaisseur du matériau des gants : 0,7 mm Mesures de protection supplémentaires pour les mains : Avant l'emploi, vérifier l'étanchéité/la perméabilité. Ne pas porter de gants dans les endroits où fonctionnent des machines et outillages en rotation. Si les gants doivent être réutilisés, les nettoyer avant de les retirer et les conserver dans un endroit bien ventilé. Remarque : Le modèle des gants spécial chimie doit être choisi en fonction des concentrations et quantités des substances chimiques spécifiques au poste. Il est conseillé de demander au fabricant des précisions concernant la tenue aux agents chimiques des gants de protection susmentionnés pour des applications spécifiques.

Eye Protection

Lunettes avec protections sur les côtés

Respiratory Protection

Lorsque les mesures techniques d'aspiration ou de ventilation ne sont pas possibles ou insuffisantes, il est indispensable de porter une protection respiratoire. Appareil de protection respiratoire approprié DIN EN 12942:2009-02 Appareil filtrant avec filtre ou dispositif filtrant avec ventilateur de type: A marron

Skin/Body Protection

Si vous portez des vêtements de travail appropriés, une blouse de travail n'est pas nécessaire. Si aucun vêtement de travail est porté, un ensemble ou une blouse de travail adaptée est nécessaire. Protection du corps appropriée : Pour protéger d'un contact dermique direct, il est nécessaire de porter une protection corporelle (en plus des vêtements de travail habituels). Chaussures de sécurité résistant aux agents chimiques Porter uniquement des vêtements de protection de bonne taille, confortables et propres. Caractéristiques exigées : antistatique. retardateur de flamme résistant à la chaleur Matériel recommandé : Fibres naturelles (coton) fibres synthétiques résistantes à la chaleur

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

3272

Packing Group

III

ADR Transport Precautions

Aucune

IMDG Maritime Transport Precautions

Aucune

IATA Air Transport Precautions

Aucune

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for HAKU GB 1250?

The signal word for this substance is "warning".

What is the physical form of HAKU GB 1250?

HAKU GB 1250 is a liquide appearing as clair with incolore color. It has caractéristique odor.

What is HAKU GB 1250 used for?

Catégories de produits [PC] PC9 - Revêtements et couleurs, matériels de remplissage, enduits, diluants PC35 - Produits de lavage et de nettoyage (y compris produits à base de solvants)

What are the hazard statements for HAKU GB 1250?

This substance has 1 hazard statements: H226: Liquide et vapeurs inflammables.

What is the melting point of HAKU GB 1250?

The melting point is < -30 °C and the boiling point is 143 - 148 °C.