Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Transbond™ LR Light Cure Adhesive
- Product Code
- 712-038
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Orthodontic use
Manufacturers & Suppliers
3M Australia
national supplier
Building A, 1 Rivett Road, North Ryde NSW 2113
136 136
www.3m.com.au
Emergency Contacts
Emergency Contact
1800 097 146
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 2-Propenoic acid, 2-methyl-, 3-(trimethoxysilyl)propyl ester, reaction products with quartz, bulk material | 100402-78-6 | 75 - 85% | No |
| Bisphenol A Diglycidyl Ether Dimethacrylate | 1565-94-2 | 5 - 15% | No |
| Triethylene Glycol Dimethacrylate | 109-16-0 | 10% | No |
| Dichlorodimethylsilane Reaction Product with Silica | 68611-44-9 | 2% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person to fresh air. If you feel unwell, get medical attention.
Immediately wash with soap and water. Remove contaminated clothing and wash before reuse. If signs/symptoms develop, get medical attention.
Flush with large amounts of water. Remove contact lenses if easy to do. Continue rinsing. If signs/symptoms persist, get medical attention.
Rinse mouth. If you feel unwell, get medical attention.
Medical Treatment
Not applicable
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use a fire fighting agent suitable for ordinary combustible material such as water or foam to extinguish.
None inherent in this product.
Firefighter Protection
Wear full protective clothing, including helmet, self-contained, positive pressure or pressure demand breathing apparatus, bunker coat and pants, bands around arms, waist and legs, face mask, and protective covering for exposed areas of the head.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate area. Ventilate the area with fresh air. For large spill, or spills in confined spaces, provide mechanical ventilation to disperse or exhaust vapors, in accordance with good industrial hygiene practice.
For large spill, or spills in confined spaces, provide mechanical ventilation to disperse or exhaust vapors
Avoid release to the environment.
Collect as much of the spilled material as possible. Clean up residue.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
A no-touch technique is recommended. If skin contact occurs, wash skin with soap and water. Acrylates may penetrate commonly-used gloves. If product contacts glove, remove and discard glove, wash hands immediately with soap and water and then re-glove. Do not eat, drink or smoke when using this product. Wash thoroughly after handling. Contaminated work clothing should not be allowed out of the workplace. Wash contaminated clothing before reuse. Do not get in eyes.
No special storage requirements.
Do not eat, drink or smoke when using this product. Wash thoroughly after handling. Contaminated work clothing should not be allowed out of the workplace. Wash contaminated clothing before reuse.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use in a well-ventilated area.
See Section 7.1 for additional information on skin protection.
Safety glasses with side shields. Select and use eye protection in accordance with AS/NZS 1336. Eye protection should comply with the performance specifications of AS/NZS 1337.
None required.
See Section 7.1 for additional information on skin protection.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable.
This material may be reactive with certain agents under certain conditions - see the remaining headings in this section
Hazardous polymerisation will not occur.
Light.
None known.
None known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of completely cured (or polymerized) material in a permitted industrial waste facility. Incinerate uncured product in a permitted waste incineration facility.
Dispose of contents/ container in accordance with the local/regional/national/international regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Not applicable
- Shipping Name
- Not applicable
- Transport Class
- Not applicable
- Packing Group
- Not applicable
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This product is regulated by the Therapeutics Goods Administration and is exempt from compliance with the Industrial Chemicals (Notification and Assessment) Act 1989 as amended.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Transbond™ LR Light Cure Adhesive?
The signal word is warning.
What is the physical form of Transbond™ LR Light Cure Adhesive?
Transbond™ LR Light Cure Adhesive is a solid. appearing as paste with off-white color. It has slight acrylate odor.
What is Transbond™ LR Light Cure Adhesive used for?
Orthodontic use
What are the hazard statements for Transbond™ LR Light Cure Adhesive?
This substance has 1 hazard statement:
- H317: May cause an allergic skin reaction.
What is the melting point of Transbond™ LR Light Cure Adhesive?
The melting point is No data available. and the boiling point is Not applicable..