NextSDS Logo
Safety Data Sheet EN

Zinc Aluminium Alloy Wire

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Zinc Aluminium Alloy Wire

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Thermal Spraying

Manufacturers & Suppliers

Z

ZINACOR S.A.

manufacturer

Centre d'Affaires Dony, rue de Chne, 53, B-4031 ANGLEUR (BELGIQUE)

+32 (0)4 366 64 74/75

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Chemical Name CAS Number Concentration Hazardous
Poudre de Zinc - poussière de zinc (stabilisée) EC: 231-175-3 7440-66-6 78 - 98% No
aluminium substance with a Community workplace exposure limit EC: 231-072-3 7429-90-5 2 - 22% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

When inhaled, move the person to fresh air and seek medical advice.

Skin contact

Wash thoroughly with plenty of water. In case of contact with molten product, cool skin area rapidly with cold water.

Eye contact

In case of contact with eyes, rinse immediately thoroughly with plenty of water and consult an ophthalmologist.

Immediate Medical Attention

Seek medical advice (for inhalation). Consult an ophthalmologist (for eye contact).

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure good ventilation. This can be achieved by local exhaust ventilation.

Hands

Hand protection must be adapted to work

Eyes

eye protection must be adapted to work

Respiratory

In the presence of ZnO smoke and dust respirator may be required (particulate filter unit with DIN EN 143).

Skin/Body

body protection must be adapted to work

Environmental

No information available at present.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
solid
Form
---
Vapor Pressure
---
Partition Coefficient
---
Colour
shiny metallic
Solidification Point
---
Odor
odorless
Upper Explosive Limit
---
Properties Status
---
Cloud Point
---
Evaporation Rate
---
Solubility In Fat
---
Auto Ignition Temperature
---
Freezing Point
---
Lower Explosive Limit
---
Voc Content
---
Flash Point
n.av.
Solubility In Water
Insoluble.
Decomposition Temperature
---
Appearance
---
Physical State Data
solid
Relative Density
---
Metal Corrosion
---
Ph
---
State Under Standard Conditions
---
Molecular Weight
---
Odor Threshold
---
Kinematic Viscosity
---
Boiling Point
n.av.
Colour Intensity
---
Softening Point
---
Flammability
---
Dynamic Viscosity
---
Solubility
---
Crystallisation Point
---
Density
~ 5,2 - 6,9 g/cm3 (depending on the alloy composition)
Explosive Limits
---
Melting Point
~ 382 - 488 (depending on the alloy composition)
Bulk Density
---
Relative Evaporation Rate
---
Vapor Density
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Zinc Aluminium Alloy Wire?

The signal word is no signal word.

What is the physical form of Zinc Aluminium Alloy Wire?

Zinc Aluminium Alloy Wire is a solid with shiny metallic color. It has odorless odor.

What is Zinc Aluminium Alloy Wire used for?

Thermal Spraying

What is the melting point of Zinc Aluminium Alloy Wire?

The melting point is ~ 382 - 488 (depending on the alloy composition) and the boiling point is n.av..