NextSDS Logo
Zi

Zinc Aluminium Alloy Wire

NO SIGNAL WORD solid SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Zinc Aluminium Alloy Wire

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Thermal Spraying

Overview

Zinc Aluminium Alloy Wire commonly used thermal spraying.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

ZINACOR S.A.

manufacturer

Centre d'Affaires Dony, rue de Chênée, 53, B-4031 ANGLEUR (BELGIQUE)

BE

+32 (0)4 366 64 74/75

+32 (0)4 366 64 77

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Zinc
EC: 231-175-3
7440-66-6 78-98% Non-hazardous
Aluminium
EC: 231-072-3
7429-90-5 2-22% Non-hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Move the person to fresh air and seek medical advice.

Symptoms:

Irritation of the respiratory tract

Skin Contact

Wash thoroughly with plenty of water. In case of contact with molten product, cool skin area rapidly with cold water.

Eye Contact

Rinse immediately thoroughly with plenty of water and consult an ophthalmologist.

Immediate Medical Attention Required

Seek medical advice (in case of inhalation). Consult an ophthalmologist (in case of eye contact).

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Bulk Density
Not available
Density
~ 5,2 – 6,9 g/cm³
Critical Property
Cloud Point
Not available
Dynamic Viscosity
Not available
Solidification Point
Not available
Relative Evaporation Rate
Not available
Form
Not available
Melting Point
~ 382 - 488 °C
Critical Property
Freezing Point
Not available
Solubility
Not available
State Under Standard Conditions
Not available
Boiling Point
n.av.
Critical Property
Flammability
Not available
Metal Corrosion
Not available
Vapor Density
Not available
Solubility In Fat
Not available
Relative Density
Not available
Physical State Data
solid
Crystallisation Point
Not available
Colour Intensity
Not available
Decomposition Temperature
Not available
Colour
shiny metallic
Odor
odorless
Appearance
Not available
Properties Status
Not available
Vapor Pressure
Not available
Voc Content
Not available
Partition Coefficient
Not available
Physical State
solid
Critical Property
Softening Point
Not available
Explosive Limits
Not available
Upper Explosive Limit
Not available
Evaporation Rate
Not available
Lower Explosive Limit
Not available
Solubility In Water
Insoluble.
Molecular Weight
Not available
Kinematic Viscosity
Not available
Ph
Not available
Odor Threshold
Not available
Auto Ignition Temperature
Not available
Flash Point
n.av.
Critical Property
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Ensure good ventilation. This can be achieved by local exhaust ventilation.

Respiratory Protection

If this is insufficient to keep the concentration below the exposure limits (OEL), suitable respiratory protection should be worn. In the presence of ZnO smoke and dust respirator may be required (particulate filter unit with DIN EN 143).

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Zinc Aluminium Alloy Wire?

The signal word for this substance is "no signal word".

What is the physical form of Zinc Aluminium Alloy Wire?

Zinc Aluminium Alloy Wire is a solid with shiny metallic color. It has odorless odor.

What is Zinc Aluminium Alloy Wire used for?

Thermal Spraying

What is the melting point of Zinc Aluminium Alloy Wire?

The melting point is ~ 382 - 488 °C and the boiling point is n.av..