NextSDS Logo
AN

ANIOSYME DD1

fluid liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
ANIOSYME DD1
Product Code
1200000

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Cleaning and pre-disinfection of medical devices

Overview

ANIOSYME DD1 commonly used cleaning and pre-disinfection of medical devices.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

N/A

Hazard Classifications

Skin Irr.
Eye Irrit.
Aquatic Acute
Aquatic Chronic

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Laboratoires ANIOS company logo - Safety Data Sheet supplier organization

Laboratoires ANIOS

manufacturer

๐Ÿ“

Pavรฉ du Moulin.59260.LILLE - HELLEMMES.FRANCE.

๐ŸŒ

FR

๐Ÿ“ž

+ 33 (0)3 20 67 67 67

๐Ÿ“ 

+ 33 (0)3 20 67 67 68

๐ŸŒ www.anios.com

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

INRS

๐Ÿ“ž

+ 33(0)1 45 42 59 59

๐ŸŒ

FR

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
PREPARATION 1200 N/A 10-25% โš ๏ธ Hazardous
N,N-DIDECYL-N-METHYL-POLY(OXYETHYL)AMMONIUM PROPIONATE 94667-33-1 2.5-10% โš ๏ธ Hazardous
SODIUM N-LAURYL B-IMINODIPROPIONATE
EC: 239-032-7
14960-06-6 2.5-10% โš ๏ธ Hazardous
ETHOXYLATED ISOTRIDECANOL 69011-36-5 2.5-10% โš ๏ธ Hazardous
MONOPROPYLENE GLYCOL
EC: 200-338-0
57-55-6 10-25% โœ“ Non-hazardous
ETHANE-1,2-DIOL,HOMOPOLYMERE 25322-68-3 2.5% โœ“ Non-hazardous
POLYHEXAMETHYLENE BIGUANIDE HYDROCHLORIDE 27083-27-8 2.5% โš ๏ธ Hazardous

Composition Notes

Full text of risk phrases appearing in section 3: see section 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Move the person away from the place of exposure and take him/her outside.

๐Ÿ–๏ธ Skin Contact

Remove all contaminated or stained clothing immediately. Do not use them again until they have been decontaminated. Rinse immediately and thoroughly with water.

Symptoms:

skin irritation

๐Ÿ‘๏ธ Eye Contact

If applicable, remove contact lenses. Wash thoroughly with soft clean water for 15 minutes, holding the eyelids open.

Symptoms:

redness, pain or visual impairment

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse out the mouth, do not allow to drink, do not induce vomiting.

๐Ÿšจ Immediate Medical Attention Required

In case of doubt or if symptoms persist, always call a doctor. If there is any redness, pain or visual impairment (eyes), consult an ophthalmologist. In the event of skin irritation, seek medical advice. Transfer immediately to hospital or doctor (ingestion).

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
fluid liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Not available
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Not available
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
neutral.
๐ŸงŠ Melting Point
not specified.
Critical Property
๐Ÿ’จ Boiling Point
not specified.
Critical Property
๐Ÿ”ฅ Flash Point
not relevant.
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
not relevant.
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
+/- 1.1
Critical Property
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
not specified.
๐Ÿ“Š Decomposition Temperature
not specified.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
Dilutable.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Ensure the rooms are well-ventilated. Atmospheric concentrations at the workplace must not exceed the limit values given for normal conditions of use.

๐Ÿงค Hand Protection

When handling this product, wear suitable gloves. Nitrile, latex or ninyle gloves. Gloves must be replaced immediately if they show signs of wear and tear.

๐Ÿ‘๏ธ Eye Protection

Avoid all contact with eyes. Make safety goggles with side protection available to the personnel. Water source nearby.

๐Ÿ˜ท Respiratory Protection

Not applicable in normal conditions of use. In case of insufficient ventilation, wear suitable breathing apparatus. Particularly universal breathing apparatus, ABEK2P3 type

๐Ÿฆบ Skin/Body Protection

For further information, see ยง 11 of S.D.S. - Toxicological information.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

3082

๐Ÿ“ฆ Proper Shipping Name

ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S.

โš ๏ธ Transport Hazard Class

9

๐Ÿ“‹ Packing Group

III

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the physical form of ANIOSYME DD1?

ANIOSYME DD1 is a fluid liquid .

What is ANIOSYME DD1 used for?

Cleaning and pre-disinfection of medical devices

What is the melting point of ANIOSYME DD1?

The melting point is not specified. and the boiling point is not specified..