NextSDS Logo
Safety Data Sheet EN

Crown 9106 Tap Tool - Aerosol

CAS Not Applicable (mixture)
EC Not Applicable (mixture)

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Crown 9106 Tap Tool - Aerosol
Product Form
Aerosol

Regulatory Identifiers

CAS Number
Not Applicable (mixture) Check regulations →
EC Number
Not Applicable (mixture) Check regulations →

Identified Uses

Use for drilling, tapping, threading, boring, broaching, reaming, turning and engraving.

Uses advised against

Poorly ventilated areas

Manufacturers & Suppliers

A

Aervoe Industries Incorporated

manufacturer

1100 Mark Circle, Gardnerville, Nevada 89410

1-775-782-0100

Emergency Contacts

CHEMTREC

1-800-424-9300

24 hrs

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Aerosol Cat. 1
Press. Gas (Comp.)
Flam. Gas Cat. 1
Flam. Liq. Cat. 3
Skin Irrit. Cat. 2
Eye Irrit. Cat. 2

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H220 Extremely flammable gas.
H222 Extremely flammable aerosol.
H226 Flammable liquid and vapor.
H229 Pressurized container: may burst if heated
H315 Causes skin irritation.
H319 Causes serious eye irritation.
H335 May cause respiratory irritation.

Precautionary Statements

P101 If medical advice is needed, have product container or label at hand
P102 Keep out of reach of children
P103 Read label before use
P210 Keep away from heat/sparks/open flames/hot surfaces - no smoking
P211 Do not spray on an open flame or other ignition source
P251 Pressurized container: Do not pierce or burn, even after use
P261 Avoid breathing dust/fume/gas/mist/vapours/spray
P262 Do not get in eyes, on skin, or on clothing
P264 Wash ... thoroughly after handling
P280 Wear protective gloves/eye protection/face protection
P303 + P361 + P353 If on skin or hair, remove/takeoff immediately all contaminated clothing. Rinse skin with water/shower.
P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50/122F
P501 Dispose of contents/container in accordance with local/regional/national/international regulation

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type Mixture
Chemical Name CAS Number Concentration Hazardous
Para- Chlorobenzotrifluoride EC: 202-681-1 98-56-6 30 - 60% Yes
Hydrocarbon Propellant EC: 270-705-8 68476-86-8 10 - 30% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and provide oxygen if breathing is difficult. If not breathing, give artificial respiration, preferably mouth to mouth. Get medical attention immediately.

Symptoms: difficulty breathing

Skin contact

Wash with soap and water. Remove contaminated clothing and shoes. Get medical attention immediately. Wash clothing before reuse.

Eye contact

If contact with eyes, immediately flush eyes with plenty of water for at least 15 minutes, while holding eyelids open. Get medical attention immediately.

Ingestion

If swallowed, wash out mouth with water provided the person is conscious. Do not induce vomiting. Never give anything by mouth to an unconscious person. Get medical attention immediately.

Immediate Medical Attention

If symptoms persist, always call a doctor. Get medical attention immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation. A system of local and/or general exhaust is recommended to keep employee exposures below the Airborne Exposure Limits. Keep away from sources of ignition. Take precautionary measures against static discharge.

Eyes

Eye & face protection devices such as safety glasses, safety goggles or face shield are recommended.

Respiratory

Use only in an adequately ventilated area. For unknown vapor concentrations use a positive-pressure, pressure-demand, self-contained breathing apparatus (SCBA).

Skin/Body

Wear the appropriate protective clothing, including boots, gloves, lab coat, apron or coveralls, as appropriate, to prevent skin contact.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Form
---
Decomposition Temperature
N/AV
Appearance
Clear water white
Vapor Pressure
N/AV
State Under Standard Conditions
---
Kinematic Viscosity
---
Freezing Point
N/AV
Relative Evaporation Rate
---
Solubility
Negligible
Auto Ignition Temperature
N/AV
Solubility In Fat
---
Softening Point
---
Upper Explosive Limit
10.5%
Solubility In Water
---
Odor Threshold
N/AV
Physical State
gas
Metal Corrosion
---
Crystallisation Point
---
Vapor Density
Heavier Than Air
Flammability
Flammable gas
Voc Content
---
Evaporation Rate
Faster than n-Butyl Acetate
Melting Point
N/AV
Boiling Point
N/AV
Dynamic Viscosity
---
Molecular Weight
---
Odor
Ethereal Odor
Solidification Point
---
Relative Density
N/AV
Cloud Point
---
Colour Intensity
Clear
Explosive Limits
---
Colour
water white
Properties Status
---
Ph
Not Applicable (solvent Base)
Bulk Density
---
Partition Coefficient
N/AV
Lower Explosive Limit
1.8%
Flash Point
< 0º F (-18° C)
Physical State Data
gas
Density
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1950
Shipping Name
Aerosols
Transport Class
2.1
Packing Group
Not Applicable
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Crown 9106 Tap Tool - Aerosol?

The signal word is danger.

What is the physical form of Crown 9106 Tap Tool - Aerosol?

Crown 9106 Tap Tool - Aerosol is a gas appearing as clear water white with water white color. It has ethereal odor odor.

What is the solubility of Crown 9106 Tap Tool - Aerosol?

Negligible

What is Crown 9106 Tap Tool - Aerosol used for?

Use for drilling, tapping, threading, boring, broaching, reaming, turning and engraving.

What are the hazard statements for Crown 9106 Tap Tool - Aerosol?

This substance has 7 hazard statements:

  • H220: Extremely flammable gas.
  • H222: Extremely flammable aerosol.
  • H226: Flammable liquid and vapor.
  • H229: Pressurized container: may burst if heated
  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.
  • H335: May cause respiratory irritation.

What is the melting point of Crown 9106 Tap Tool - Aerosol?

The melting point is N/AV and the boiling point is N/AV.

Compliance Scanner

Scan your compliance