NextSDS Logo
Safety Data Sheet EN

ARDROX 996PB, Aerosol

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ARDROX 996PB, Aerosol
Product Form
Aerosol

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Red penetrative liquid.

Uses advised against

None known

Manufacturers & Suppliers

C

Chemetall Ltd.

manufacturer

Denbigh Road 65, Bletchley Milton Keynes MK1 1PB, Great Britain

+44 1908 649333

S

Sil-Mid Limited

distributor

Roman Park, Roman Way, Coleshill, West Midlands, B46 1HG. UK

01675 432850

Emergency Contacts

Sil-Mid Limited

+44 (0)1675 432850

Monday to Friday, 08:00 – 17:30 – GMT

International emergency number

+49 180 2273-112

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Eye Irrit. Cat. 2 H319
Aerosol Cat. 1 H222
Aerosol Cat. 1 H229

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H222 Extremely flammable aerosol.
H229 Pressurized container: May burst if heated.
H319 Causes serious eye irritation.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P211 Do not spray on an open flame or other ignition source.
P233 Keep container tightly closed.
P240 Ground and bond container and receiving equipment.
P241 Use explosion-proof electrical/ventilating/lighting/equipment.
P242 Use only non-sparking tools.
P243 Take action to prevent static discharges.
P251 Do not pierce or burn, even after use.
P264 Wash with plenty of water and soap thoroughly after handling.
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER or doctor/physician.
P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P331 Do NOT induce vomiting.
P337 + P313 If eye irritation persists: Get medical advice/attention.
P370 + P378 In case of fire: Use water spray for extinction.
P403 + P235 Store in a well-ventilated place. Keep cool.
P405 Store locked up.
P410 + P412 Protect from sunlight. Do no expose to temperatures exceeding 50°C/ 122°F.
P501 Dispose of contents/container to hazardous or special waste collection point.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Blend based on: organic solvent

Chemical Name CAS Number Concentration Hazardous
2-(2-butoxyethoxy)ethanol EC: 203-961-6 112-34-5 10 - 12.5% Yes
2-Naphthalenol, 1-[[4-(phenylazo)phenyl]azo]-, ar-heptyl ar',ar"-Me derivs. EC: 296-120-8 92257-31-3 0.5 - 1% Yes
N/A --- 20 - 25% Yes

Notes

For the classifications not written out in full in this section, including the hazard classes and the hazard statements, the full text is listed in section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove the affected individual into fresh air and keep the person calm. If symptoms persist, seek medical advice.

Skin contact

Wash affected areas thoroughly with soap and water. If symptoms persist, seek medical advice.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 30 minutes. Seek medical attention.

Ingestion

Rinse mouth immediately with water. Do not induce vomiting. Seek medical attention.

Immediate Medical Attention

Seek medical attention.

Medical Treatment

Treat according to symptoms (decontamination, vital functions)

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

carbon dioxide, dry powder, alcohol-resistant foam, water spray

Unsuitable media

water jet

Specific hazards

carbon oxides

Instructions

Cool endangered containers with water-spray.

Firefighter Protection

Wear a self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Do not discharge into drains/surface waters/groundwater. Do not discharge into the subsoil/soil.

Cleanup methods

Contain and collect spillage with non-combustible absorbent materials. Clean preferably with a detergent; avoid the use of solvents.

Materials: sand, earth, vermiculite, diatomaceous earth

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Provide good ventilation of working area (local exhaust ventilation if necessary). In closed rooms provide exhaust ventilation at floor level. The workplace should be equipped with an emergency shower and eye-rinsing facility. Warn users about safety measures and precautions to prevent accidents.

Storage

Keep container dry. Keep container tightly closed in a cool, well-ventilated place. The entrance to storage rooms is to be granted only to appropriately trained personnel. Keep away from heat. Avoid direct sunlight.

Hygiene

The workplace should be equipped with an emergency shower and eye-rinsing facility.

Fire prevention

Keep away from sources of ignition - No smoking. Take precautionary measures against static discharges. Vapours may form explosive mixture with air. The relevant fire protection measures should be noted.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Adequate ventilation should be ensured to prevent exposure to hazardous substances.

Hands

nitrile rubber (Buna N). Use suitable protective gloves made of nitrile rubber or butyl rubber. Please observe the glove manufacturer's instructions on permeability and ruptur times as well as the specific workplace conditions. Chemical resistant protective gloves (EN 374). Further information on penetration time is available from the manufacturer of the glove. The protection glove should be tested for its specific suitability (e.g. mechanical strength, product compatibility, anti-static properties).

Eyes

Tightly fitting safety goggles (splash goggles) (e.g. EN 166)

Respiratory

Wear respiratory protection if ventilation is inadequate. (Combination filter EN 14387 AX-P)

Skin/Body

Chemical resistant protective clothing according to DIN EN 13034 (Type 6)

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Lower Explosive Limit
not determined
Melting Point
not determined
Freezing Point
---
Molecular Weight
---
Ph
not applicable
Odor Threshold
---
Bulk Density
---
Colour
red
Solidification Point
---
Form
aerosol
Solubility
---
Kinematic Viscosity
(40 °C) not determined
Softening Point
---
Vapor Pressure
(20 °C) not determined; (50 °C) not determined
Relative Evaporation Rate
---
Density
0.86 g/cm³
Solubility In Water
immiscible
Colour Intensity
---
Odor
of hydrocarbons
Decomposition Temperature
---
Cloud Point
---
Auto Ignition Temperature
not determined
Crystallisation Point
---
Properties Status
---
State Under Standard Conditions
---
Vapor Density
---
Flash Point
> 93 °C, -60 °C
Explosive Limits
---
Appearance
---
Physical State Data
aerosol
Partition Coefficient
---
Solubility In Fat
---
Flammability
Extremely flammable.
Dynamic Viscosity
---
Physical State
aerosol
Voc Content
---
Metal Corrosion
---
Boiling Point
not determined
Relative Density
---
Upper Explosive Limit
---
Evaporation Rate
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable if stored and handled as prescribed/indicated.

Reactivity

No hazardous reactions if stored and handled as prescribed/indicated.

Hazardous reactions

Vapours may form explosive mixture with air.

Avoid

Avoid all sources of ignition: heat, sparks, open flame. Avoid direct sunlight. Avoid prolonged exposure to extreme heat.

Incompatible

strong oxidizing agents

Decomposition

No hazardous decomposition products if stored and handled as prescribed/indicated.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Observe national and local legal requirements.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
AEROSOLS
Transport Class
2.1
Packing Group
Not applicable
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

For a mixture it is not mandatory to include an exposure scenario in the material safety data sheet.

Chemical Safety Assessment Not performed

The general risk management measures related to the physico-chemical hazard of the product are communicated in chapter 2-14 of this SDS; they are to be considered by the (downstream) user when assessing the risks in accordance with his specific operating conditions and workplace environment.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for ARDROX 996PB, Aerosol?

The signal word is danger.

What is the physical form of ARDROX 996PB, Aerosol?

ARDROX 996PB, Aerosol is a aerosol with red color. It has of hydrocarbons odor.

What is ARDROX 996PB, Aerosol used for?

Red penetrative liquid.

What are the hazard statements for ARDROX 996PB, Aerosol?

This substance has 3 hazard statements:

  • H222: Extremely flammable aerosol.
  • H229: Pressurized container: May burst if heated.
  • H319: Causes serious eye irritation.

What is the melting point of ARDROX 996PB, Aerosol?

The melting point is not determined and the boiling point is not determined.

Compliance Scanner