Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Interflon Food Grease LT2
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Lubricant
Uses advised against
No further relevant information available.
Manufacturers & Suppliers
Interflon b.v.
manufacturer
P.O. Box 1070, NL-4700 BB Roosendaal, The Netherlands
+31(0)165.55.39.11
http://www.interflon.com
Emergency Contacts
Emergency Contact
+31 (0)165 55 39 11
Monday to Friday from 8:30am to 17:00pm
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture of synthetic oils, aluminium complex thickener, additives and Teflon®.
See SDS Section 16 for full text of hazard statements.
Notes
Dangerous components: Void
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Generally the product does not irritate the skin.
Rinse opened eye for several minutes under running water.
If symptoms persist consult doctor.
Medical Treatment
No further relevant information available.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use fire extinguishing methods suitable to surrounding conditions, CO2, sand, extinguishing powder, Foam
Water
Formation of toxic gases is possible during heating or in case of fire.
Firefighter Protection
Wear self-contained respiratory protective device. Use personal protective equipment (EN469).
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Clear spills immediately.
Do not allow to enter sewers/ surface or ground water.
Pick up mechanically.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
No special precautions are necessary if used correctly.
Store in accordance with local/regional/national/international regulations. Keep container tightly closed. Store in a dry place.
No special measures required.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see item 7.
No chemical-protective gloves required. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Not required. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Practical experience has shown that gloves of neoprene, Nitril and PVC offer sufficient protection. Breakthrough time: < 60 minutes. Penetration time of glove material: Not required. The penetration times are not determined by method EN 374 Part 3.
Not required.
Not required.
Wear suitable protective clothing (EN ISO 13688).
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal storage and use conditions.
No reactivity hazards known under normal storage and use conditions.
No dangerous reactions known.
To avoid thermal decomposition do not overheat. No further relevant information available.
Strong oxidising agents.
Carbon monoxide and partially combusted carbohydrates can be released during thermal decomposition. Fluoride compounds can be released from 400°C.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Must not be disposed together with household garbage. Waste should not be disposed of by release to sewers. Final decisions on the appropriate waste management method, in line with regional, national and European legislation, and possible adaptation to local conditions, remains the responsibility of the waste treatment operator.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Void
- Shipping Name
- Void
- Transport Class
- Void
- Packing Group
- Void
Not applicable.
Not applicable.
Not applicable.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Interflon Food Grease LT2?
The signal word is no signal word.
What is the physical form of Interflon Food Grease LT2?
Interflon Food Grease LT2 is a pasty with white color. It has oily odor.
What is Interflon Food Grease LT2 used for?
Lubricant
What is the melting point of Interflon Food Grease LT2?
The melting point is Not applicable. and the boiling point is Not applicable..