NextSDS Logo
Safety Data Sheet EN

Adhesive mixture for producing glueboards for U.V. lamps.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Adhesive mixture for producing glueboards for U.V. lamps.
Product Code
all the codes from P-B06XXXXXX to P-N06XXXXX, and personalized codes.

Regulatory Identifiers

CAS Number
N/A

Identified Uses

adhesive mixture for the production of glue traps for flies and flying insects.

Uses advised against

all those not mentioned in the identified uses.

Manufacturers & Suppliers

G

GEA s.r.l.

manufacturer

Via Fermi, 10 – 20019 Settimo Milanese (MI)

+39 02 33514890

Emergency Contacts

National Poisons Information Service-NHS 111 Service

111

available 24h/day, 365 days/year

Gea emergency phone number

+39.(0)2.33514890

available from 9.00 a.m. to 6.00 p.m., from Monday, to Friday, for technical assistance only

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Skin Sens. Cat. 1 H317
Aquatic Chronic Cat. 3 H412

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H317 May cause an allergic skin reaction.
H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P101 If medical advice is needed, have product container or label at hand.
P102 Keep out of reach of children.
P273 Avoid release to the environment.
P280 Wear protective gloves/eye protection.
P302 + P352 If on skin: Wash with plenty of soap and water.
P333 + P313 If skin irritation or rash occurs: Get medical advice/attention.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

adhesive mixture.

Chemical Name CAS Number Concentration Hazardous
Reaction mass of Bis (1,2,2,6,6-pentamethyl-4-piperidyl) sebacate and Methyl 1,2,2,6,6-pentamethyl-4-piperidyl sebacate. --- 0.1 - 1% Yes
2-(2H-Benzotriazol-2-yl)-4,6-diteripentyIphenol EC: 247-384-8 25973-55-1 0.1 - 1% Yes

Declaration of the ingredients complying with the CLP (CE) n1272/2008. For full text of the H statements (Hazardous statements) see section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air, consult a doctor if complaint persists.

Skin contact

wash with soap or liquid paraffin.

Symptoms: Rash, Urticaria

Eye contact

wash with plenty of running water.

Ingestion

consult a doctor.

Immediate Medical Attention

See section: Description of first aid measures.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

foam, fire extinguishing powders, carbon dioxide. For the not-burst product losses and discharges, water spray can be used to waste inflammable vapours and protect all the people working to stop the loss.

Unsuitable media

water jets must not be used. Water is not effective to extinguish fire, but it can be used to cool the closed drums which are exposed to fire.

Specific hazards

toxic gases can be released in case of fire.

Instructions

Water is not effective to extinguish fire, but it can be used to cool the closed drums which are exposed to fire. This is necessary to prevent explosions.

Firefighter Protection

Wear self-contained breathing apparatus. Wear protective equipment.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear protective equipment. Avoid contact with skin and eyes. Keep unprotected people away.

Environmental

Do not release into the environment. Do not empty into drains, surface water, ground water.

Cleanup methods

Remove mechanically.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wash hands before work breaks and after finishing work. Do not eat, drink or smoke while working.

Hygiene

Wash hands before work breaks and after finishing work. Do not eat, drink or smoke while working.

Fire prevention

no special measures are required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

ensure a good ventilation/suction.

Hands

Wear refractive gloves category III (ref. Reg. EN374). For the gloves material it's necessary to consider: compatibility, degradation, time-to-break and permeation. In case of mixture, the gloves durability to chemical agents must be checked before their use since it is not predictable. The gloves consumption depends on their use durability and way.

Eyes

Goggles which can be tightly sealed. (ref. Reg. EN 166).

Respiratory

In case of dust formation, we recommend wearing of appropriate respiratory protection equipment with particle filter P. This recommendation should be matched to local conditions.

Skin/Body

Wear protective equipment with long sleeves and safety shoes for professional use of I category (ref. Reg. 89/686/CEE and EN ISO 20344). Rinse with water and soap after have removed the protective clothes.

Environmental

The emissions coming from manufacturing processes, included those from ventilation devices, should be checked in order to comply with the regulations on environmental protection.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Vapor Density
no data available.
Voc Content
---
Lower Explosive Limit
no data available.
Flammability
no data available.
Solubility
no data available.
Physical State Data
solid
State Under Standard Conditions
---
Appearance
solid material
Solidification Point
---
Properties Status
---
Softening Point
---
Colour
colourless
Form
---
Decomposition Temperature
no data available.
Solubility In Fat
---
Flash Point
> 200°C
Colour Intensity
---
Odor
characteristic
Auto Ignition Temperature
no data available.
Density
---
Cloud Point
---
Ph
no data available.
Odor Threshold
no data available.
Evaporation Rate
no data available.
Kinematic Viscosity
non applicabile
Crystallisation Point
---
Metal Corrosion
---
Melting Point
no data available.
Partition Coefficient
no data available.
Physical State
solid material
Bulk Density
---
Relative Density
not defined.
Boiling Point
no data available.
Vapor Pressure
no data available.
Solubility In Water
---
Molecular Weight
---
Dynamic Viscosity
800 – 1.400 mPa s
Freezing Point
no data available.
Relative Evaporation Rate
---
Explosive Limits
---
Upper Explosive Limit
no data available.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage and use conditions.

Reactivity

Stable under recommended storage and use conditions.

Hazardous reactions

None under use and storage conditions.

Avoid

None. Nevertheless, comply with the usual cautions towards chemical products.

Incompatible

None if used properly.

Decomposition

No decomposition if used according to specifications.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

In consultation with the responsible local authority, it must be subjected to special treatment.

Disposal

In consultation with the responsible local authority, it must be subjected to special treatment.

Waste Codes

08 04 09 Waste adhesives and sealants containing organic solvents or other dangerous substances EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Adhesive mixture for producing glueboards for U.V. lamps.?

The signal word is warning.

What is the physical form of Adhesive mixture for producing glueboards for U.V. lamps.?

Adhesive mixture for producing glueboards for U.V. lamps. is a solid material appearing as solid material with colourless color. It has characteristic odor.

What is the solubility of Adhesive mixture for producing glueboards for U.V. lamps.?

no data available.

What is Adhesive mixture for producing glueboards for U.V. lamps. used for?

adhesive mixture for the production of glue traps for flies and flying insects.

What are the hazard statements for Adhesive mixture for producing glueboards for U.V. lamps.?

This substance has 2 hazard statements:

  • H317: May cause an allergic skin reaction.
  • H412: Harmful to aquatic life with long lasting effects.

What is the melting point of Adhesive mixture for producing glueboards for U.V. lamps.?

The melting point is no data available. and the boiling point is no data available..