Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LOCTITE AA 349 UV GLASS BONDER known as Impruv® Optically Clear UV Adh
- Product Code
- 88489
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Ultraviolet adhesive
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
http://www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Isobornyl methacrylate | 7534-94-3 | 10 - 30% | No |
| Hydroxyalkyl methacrylate | 27813-02-1 | 10 - 30% | No |
| dodecyl methacrylate | 142-90-5 | 5 - 10% | No |
| Acrylic acid | 79-10-7 | 1 - 5% | No |
| Tetradecyl methacrylate | 2549-53-3 | 1 - 5% | No |
| Gamma-glycidoxypropyl trimethoxysilane | 2530-83-8 | 1 - 5% | No |
| Hexadecyl methacrylate | 2495-27-4 | 1 - 5% | No |
| Methyl methacrylate | 80-62-6 | 0.1 - 1% | No |
Notes
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.
Immediately flush skin with plenty of water (using soap, if available). Remove contaminated clothing and footwear. If symptoms develop and persist, get medical attention. Wash clothing before reuse.
Flush with copious amounts of water, preferably, lukewarm water for at least 15 minutes, holding eyelids open all the time. Get medical attention.
Do not induce vomiting. Never give anything by mouth to an unconscious person. Keep individual calm. Get medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam, dry chemical or carbon dioxide.
Uncontrolled polymerization may cause rapid evolution of heat and increase in pressure that could result in violent rupture of sealed storage vessels or containers.
In case of fire, keep containers cool with water spray.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Do not allow product to enter sewer or waterways.
Ensure adequate ventilation. Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Store in a partly filled, closed container until disposal.
Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)
Related Products
Similar products with comparable safety profiles
LOCTITE AA 3491 LC known as LOCTITE OPTICALLY CLEAR
---
LOCTITE AA 3311 MED UV CURE known as Loctite 3311 Med.UV 1L
---
LOCTITE ECCOBOND LUX UV90 known as Ablelux UV90 (12g)
---
LOCTITE DURO-TAK UV 4310
---
LOCTITE AA 330 1K GEN.BOND ACRYLIC
---
LOCTITE DURO-TAK UV 4194B
---
LOCTITE AA 3942 UV ACRYLIC ADHESIVE known as 3942 Light Cure Medical Device
---
LOCTITE AA 3974 LIGHT CURE ADHESIVE known as LOCTITE® 3974™ LIGHT CURE ADHE
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use only with adequate ventilation. Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling. Do not taste or swallow.
Store at or below 38 °C (100.4 °F). Keep in a cool, well ventilated area away from heat, sparks and open flame. Keep container tightly closed until ready for use.
Wash thoroughly after handling.
Keep away from heat, sparks and open flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and use.
Not available.
None under normal processing. Polymerization may occur at elevated temperature or in the presence of incompatible materials.
Heat, flames, sparks and other sources of ignition. Store away from incompatible materials. Protect from direct sunlight. Freezing conditions. UV light. Inert gas blanketing. Avoid moisture.
Strong oxidizing agents. Reducing agents. Acids. Bases. Heavy metals. Free radical initiators. Copper alloys. Inert gases. Oxygen scavengers. Alkalis.
Oxides of carbon. Oxides of nitrogen. Silicon dioxide. Formaldehyde. Irritating organic vapours.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LOCTITE AA 349 UV GLASS BONDER known as Impruv® Optically Clear UV Adh?
The signal word is danger.
What is the physical form of LOCTITE AA 349 UV GLASS BONDER known as Impruv® Optically Clear UV Adh?
LOCTITE AA 349 UV GLASS BONDER known as Impruv® Optically Clear UV Adh is a liquid with clear color. It has sharp, irritating odor.
What is the solubility of LOCTITE AA 349 UV GLASS BONDER known as Impruv® Optically Clear UV Adh?
Slight Water
What is LOCTITE AA 349 UV GLASS BONDER known as Impruv® Optically Clear UV Adh used for?
Ultraviolet adhesive
What are the hazard statements for LOCTITE AA 349 UV GLASS BONDER known as Impruv® Optically Clear UV Adh?
This substance has 3 hazard statements:
- H315: CAUSES SKIN IRRITATION.
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H318: CAUSES SERIOUS EYE DAMAGE.
What is the melting point of LOCTITE AA 349 UV GLASS BONDER known as Impruv® Optically Clear UV Adh?
The melting point is Not applicable, Product is a liquid and the boiling point is > 149 °C (> 300.2 °F).