Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Interflon Metal Clean (aerosol)
- Product Form
- aerosol
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Industrial cleaner
Manufacturers & Suppliers
Interflon b.v.
manufacturer
P.O. Box 1070, NL-4700 BB Roosendaal, The Netherlands
+31(0)165.55.39.11
http://www.interflon.com
Emergency Contacts
UK National Poisons Emergency number
+44 870 600 6266
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS08
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Blend of solvents. Propellant gas carbon dioxide.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrocarbons, C6-C7, n-alkanes, isoalkanes, cyclics, <5% n-hexane EC: 921-024-6 | --- | 25 - 50% | Yes |
| ethanol EC: 200-578-6 | 64-17-5 | 25 - 50% | Yes |
| 1,3-dioxolane EC: 211-463-5 | 646-06-0 | 2.5 - 10% | Yes |
| propan-2-ol EC: 200-661-7 | 67-63-0 | 2.5 - 10% | Yes |
| cyclohexane EC: 203-806-2 | 110-82-7 | 2.5 - 10% | Yes |
| carbon dioxide EC: 204-696-9 | 124-38-9 | 2.5 - 10% | Yes |
| n-hexane EC: 203-777-6 | 110-54-3 | 2.5% | Yes |
Note: Any entry in the EC column that begins with the number "9" is a Provisional List Number provided by ECHA pending publication of the official EC Inventory Number for the substance. SVHC: This product does not contain "very worrisome substances" (SVHC) that are very dangerous to human health or the environment.
Notes
This product does not contain "very worrisome substances" (SVHC) that are very dangerous to human health or the environment. (SVHC <0.1% (w / w) Regulation (EC) No. 1907/2006 (REACH), Article 57).
First Aid Measures
Emergency procedures for chemical exposure incidents
In case of unconsciousness place patient stably in side position for transportation.
Immediately wash with water and soap and rinse thoroughly.
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
If symptoms persist consult doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use fire extinguishing methods suitable to surrounding conditions. CO2, sand, powder, water spray. Foam.
Formation of toxic gases is possible during heating or in case of fire.
Firefighter Protection
Wear self-contained respiratory protective device. Use personal protective equipment.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear protective equipment. Keep unprotected persons away.
Do not allow to enter sewers/ surface or ground water.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation/exhaustion at the workplace.
Store in a cool location. Observe official regulations on storing packagings with pressurised containers. Protect from heat and direct sunlight. Store in a cool and dry place.
Do not spray onto a naked flame or any incandescent material. Keep ignition sources away - Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ventilation or extraction. Additional information about design of technical facilities: No further data; see item 7.
Protective gloves. Material of gloves: Nitril. Glove thickness: 0,13 mm. Breakthrough time: > 15 minutes. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application.
Tightly sealed goggles (EN166)
Do not breathe vapour and sprayer mist. Use suitable respiratory protective device in case of insufficient ventilation.
Protective work clothing (EN340)
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No dangerous reactions known.
sun-ray, temperatures above 50 °C, open fire, piercing can, do not overheat.
Strong oxidising agents.
In case of thermal degradation hazardous gases may be formed (for example CO, CO2 and NOx).
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Must not be disposed together with household garbage. Do not allow product to reach sewage system.
Dispose of contents/container in accordance with local/regional/national/international regulations.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1950
- Shipping Name
- A E R O S O L S, E NV I R O N M E N T A L L Y HAZARDOUS
- Transport Class
- 2.1
- Packing Group
- Void
Warning: Gases.
Warning: Gases.
Warning: Gases.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Interflon Metal Clean (aerosol)?
The signal word is danger.
What is the physical form of Interflon Metal Clean (aerosol)?
Interflon Metal Clean (aerosol) is a aerosol with colourless color. It has citrus odor.
What is Interflon Metal Clean (aerosol) used for?
Industrial cleaner
What are the hazard statements for Interflon Metal Clean (aerosol)?
This substance has 6 hazard statements:
- H222: Extremely flammable aerosol. Pressurised container: May burst if heated.
- H304: May be fatal if swallowed and enters airways.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
- H411: Toxic to aquatic life with long lasting effects.
What is the melting point of Interflon Metal Clean (aerosol)?
The melting point is Undetermined. and the boiling point is < 0 °C.