Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Interflon Clean Special
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
cleaning agent
Manufacturers & Suppliers
Interflon BV
national supplier
Belder 47, 4704 RK Roosendaal, Netherlands
+31 (0)165 553911
http://www.Interflon.com
Emergency Contacts
National Poisons Centre / WHO Collaborating Centre for drug Information Western-Pacific Region
1 800 88 90 99
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture of organic acids, surface-active substances and water
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Phosphoric Acid 31% | 7664-38-2 | 25 - 50% | Yes |
| 2-butoxyethanol | 111-76-2 | 5 - 7.5% | Yes |
| Isotridecanol, ethoxylated | 9043-30-5 | 1 - 2.5% | Yes |
| Benzenesulfonic acid, 4-C10-13-sec-alkyl derivs. | 85536-14-7 | 1 - 2.5% | Yes |
| Citric acid | 77-92-9 | 1 - 2.5% | Yes |
| Hydrochloric Acid | 7647-01-0 | 1 - 2.5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If breathing is irregular or stopped, immediately seek medical assistance and start first aid actions. In case of respiratory tract irritation, consult a physician. Provide fresh air.
Take off immediately all contaminated clothing. Wash with plenty of soap and water.
Remove contact lenses, if present and easy to do. Continue rinsing. Irrigate copiously with clean, fresh water for at least 10 minutes, holding the eyelids apart.
Rinse mouth with water (only if the person is conscious). Do NOT induce vomiting.
Immediate Medical Attention
In all cases of doubt, or when symptoms persist, seek medical advice. If breathing is irregular or stopped, immediately seek medical assistance.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water mist, Fire extinguishing powder, Carbon dioxide (CO2)
Water jet
In case of insufficient ventilation and/or in use, may form flammable/explosive vapour-air mixture. Solvent vapours are heavier than air and may spread along floors. Places which are not ventilated, e.g. unventilated below ground level areas such as trenches, conduits and shafts, are particularly prone to the presence of flammable substances or mixtures. Substance or mixture corrosive to metals.
Co-ordinate firefighting measures to the fire surroundings. Fight fire with normal precautions from a reasonable distance.
Firefighter Protection
Use suitable breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Remove persons to safety.
Keep away from drains, surface and ground water. Retain contaminated washing water and dispose of it.
Wipe up with absorbent material (e.g. cloth, fleece). Collect spillage: sawdust, kieselgur (diatomite), sand, universal binder
Materials: cloth, fleece, sawdust, kieselgur (diatomite), sand, universal binder
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use local and general ventilation. Avoidance of ignition sources. Keep away from sources of ignition - No smoking. Take precautionary measures against static discharge. Use only in well-ventilated areas. Due to danger of explosion, prevent leakage of vapours into cellars, flues and ditches. Never add water to this product. Ground/bond container and receiving equipment. Use explosion-proof electrical/ventilating/lighting/equipment. Use only non-sparking tools.
Store in accordance with local/regional/national/international regulations. Keep container tightly closed and in a well-ventilated place.
Remove contaminated clothing and protective equipment before entering eating areas. Never place chemicals in containers that are normally used for food or drink.
Avoidance of ignition sources. Keep away from sources of ignition - No smoking. Take precautionary measures against static discharge. Ground/bond container and receiving equipment. Use explosion-proof electrical/ventilating/lighting/equipment. Use only non-sparking tools.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use only in well-ventilated areas.
Not required.
Use safety goggle with side protection.
In case of insufficient ventilation, wear suitable respiratory equipment. In case of inadequate ventilation wear respiratory protection.
Take recovery periods for skin regeneration. Preventive skin protection (barrier creams/ointments) is recommended. Wash hands thoroughly after handling.
Use appropriate container to avoid environmental contamination. Keep away from drains, surface and ground water.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
See below "Conditions to avoid".
The mixture contains reactive substance(s). Risk of ignition. Substance or mixture corrosive to metals.
No known hazardous reactions.
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Use explosion-proof electrical/ventilating/lighting/equipment. Use only non-sparking tools. Take precautionary measures against static discharge.
Oxidisers
Hazardous combustion products: see section 5.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3264
- Shipping Name
- CORROSIVE LIQUID, ACIDIC, INORGANIC, N.O.S.
- Transport Class
- 8
- Packing Group
- II
Provisions for dangerous goods (ADR) should be complied within the premises.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Interflon Clean Special?
The signal word is danger.
What is the physical form of Interflon Clean Special?
Interflon Clean Special is a liquid with colourless color. It has characteristic odor.
What is the solubility of Interflon Clean Special?
not determined
What is Interflon Clean Special used for?
cleaning agent
What are the hazard statements for Interflon Clean Special?
This substance has 3 hazard statements:
- H227: Combustible liquid.
- H290: May be corrosive to metals.
- H314: Causes severe skin burns and eye damage.
What is the melting point of Interflon Clean Special?
The melting point is not determined and the boiling point is 100 °C.