Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Interflon Metal Clean
- Product Form
- aerosol
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Industrial cleaner
Uses advised against
No further relevant information available.
Manufacturers & Suppliers
Interflon b.v.
manufacturer
P.O. Box 1070, NL-4700 BB Roosendaal, The Netherlands
+31(0)165.55.39.11
http://www.interflon.com
Interflon USA
distributor
555 Route 78, Suite 403, Swanton, Vermont, 05488 USA
1 877 FIN LUBE
Emergency Contacts
Emergency Contact
1-800-255-3924
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Blend of solvents. Propellant gas carbon dioxide.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrocarbons, C6-C7, n-alkanes, isoalkanes, cyclics, <5% n-hexane EC: 921-024-6 | --- | 25 - 50% | Yes |
| ethanol EC: 200-578-6 | 64-17-5 | 25 - 50% | Yes |
| 1,3-dioxolane EC: 211-463-5 | 646-06-0 | 2.5 - 10% | Yes |
| propan-2-ol EC: 200-661-7 | 67-63-0 | 2.5 - 10% | Yes |
| cyclohexane EC: 203-806-2 | 110-82-7 | 2.5 - 10% | Yes |
| carbon dioxide EC: 204-696-9 | 124-38-9 | 2.5 - 10% | Yes |
| n-hexane EC: 203-777-6 | 110-54-3 | 2.5% | Yes |
Note: Any entry in the EC column that begins with the number "9" is a Provisional List Number provided by ECHA pending publication of the official EC Inventory Number for the substance. See Section 16 for additional CAS number information for the substance. For the wording of the listed risk phrases refer to section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
In case of unconsciousness place patient stably in side position for transportation.
Immediately wash with water and soap and rinse thoroughly.
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
If symptoms persist consult doctor.
Medical Treatment
No further relevant information available.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use fire fighting measures that suit the environment. CO2, sand, powder, water spray. Foam
Formation of toxic gases is possible during heating or in case of fire.
Use fire fighting measures that suit the environment.
Firefighter Protection
Wear self-contained respiratory protective device. Use personal protective equipment.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Keep unprotected persons away.
Do not allow to enter sewers/ surface or ground water.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation/exhaustion at the workplace.
Store in a cool and dry place. Protect from heat and direct sunlight. Observe official regulations on storing packagings with pressurized containers.
Do not spray on a naked flame or any incandescent material. Keep ignition sources away - Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Additional information about design of technical systems: No further data; see item 7. Ventilation or extraction.
Protective gloves. Material of gloves: The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Practical experience has shown that gloves of Nitril offer sufficient protection. Glove thickness: 0,13 mm. Breakthrough time: > 15 minutes. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.
Tightly sealed goggles
Do not breathe vapour and sprayer mist. Use suitable respiratory protective device in case of insufficient ventilation. Filter A/P2
Protective work clothing
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No dangerous reactions known.
sun-ray, temperatures above 50 °C, open fire, piercing can. To avoid thermal decomposition do not overheat.
Strong oxidising agents.
In case of thermal degradation, hazardous gases may be formed (for example CO, CO2 and NOx).
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Must not be disposed of together with household garbage. Do not allow product to reach sewage system.
Must not be disposed of together with household garbage. Do not allow product to reach sewage system.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1950
- Shipping Name
- Aerosols, ENVIRONMENTALLY HAZARDOUS
- Transport Class
- 2.1
- Packing Group
- Void
Warning: Gases
Warning: Gases
Warning: Gases
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Interflon Metal Clean?
The signal word is danger.
What is the physical form of Interflon Metal Clean?
Interflon Metal Clean is a aerosol appearing as aerosol, colorless with colorless color. It has citrus odor.
What is Interflon Metal Clean used for?
Industrial cleaner
What are the hazard statements for Interflon Metal Clean?
This substance has 6 hazard statements:
- H222: Extremely flammable aerosol. Pressurized container: May burst if heated.
- H304: May be fatal if swallowed and enters airways.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
- H350: May cause cancer.
What is the melting point of Interflon Metal Clean?
The melting point is Undetermined. and the boiling point is < 0 °C (< 32 °F).