NextSDS Logo
In

Interflon Metal Clean (aerosol)

WARNING SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Interflon Metal Clean (aerosol)

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Metal degreaser.

Overview

Interflon Metal Clean (aerosol) commonly used metal degreaser..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning!)

Hazard Classifications

Skin Irr. Category 2
Aerosol Category 1
Aquatic Acute Category 1
Aquatic Chronic Category 2
STOT SE Category 3

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Interflon b.v. company logo - Safety Data Sheet supplier organization

Interflon b.v.

manufacturer

๐Ÿ“

P.O. Box 1070 NL-4700 BB Roosendaal The Netherlands

๐ŸŒ

NL

๐Ÿ“ 

+31(0)165.53.80.82

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+31(0)165.55.39.11

๐ŸŒ

NL

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Mixture of aliphatic- and oxidised hydrocarbons and propellant= CO2.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Naphtha (petroleum), hydrotreated light
EC: 265-151-9
64742-49-0 25-50% โš ๏ธ Hazardous
propan-2-ol
EC: 200-661-7
67-63-0 2.5-10% โš ๏ธ Hazardous

Additional Information

For the wording of the listed risk phrases refer to section 16.

Composition Notes

Interflon Metal Clean is listed by the NSF for use in the food industry (NSF K1 and K3) with registration number 140150.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

In case of unconsciousness place patient stably in side position for transportation.

๐Ÿ–๏ธ Skin Contact

Immediately wash with water and soap and rinse thoroughly.

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do not induce vomiting; call for medical help immediately.

๐Ÿšจ Immediate Medical Attention Required

call for medical help immediately.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Not available
๐Ÿ“Š Physical State Data
Not available
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Colourless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Aerosol
๐Ÿ‘ƒ Odor
Characteristic
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
Not available
๐ŸงŠ Melting Point
Undetermined.
Critical Property
๐Ÿ’จ Boiling Point
Not applicable, as aerosol.
Critical Property
๐Ÿ”ฅ Flash Point
< 21C
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
5.5 bar
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
0,762 g/ml (cleaner)
Critical Property
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
19% (in air)
๐Ÿ“Š Lower Explosive Limit
0,8% (in air)
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
425C (cleaner)
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
Partly soluble.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

Protective gloves. Material of gloves: Neoprene gloves. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

๐Ÿ‘๏ธ Eye Protection

Tightly sealed goggles

๐Ÿ˜ท Respiratory Protection

Use suitable respiratory protective device in case of insufficient ventilation.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

1950

๐Ÿ“ฆ Proper Shipping Name

AEROSOLS, FLAMMABLE

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Interflon Metal Clean (aerosol)?

The signal word for this substance is "warning".

What is Interflon Metal Clean (aerosol) used for?

Metal degreaser.

What is the melting point of Interflon Metal Clean (aerosol)?

The melting point is Undetermined. and the boiling point is Not applicable, as aerosol..