NextSDS Logo
Safety Data Sheet EN

Gyproc JointFiller 45

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Gyproc JointFiller 45

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Gypsum-based jointfiller for interior use.

Manufacturers & Suppliers

S

Saint-Gobain Rigips Austria GesmbH

manufacturer

Wiener Neustädterstraße 63, A-2734 Puchberg, Austria

+43 (0)2636 2203-616

Emergency Contacts

Vergiftungsinformationszentrale Vienna

+43 (0)1 406 43 43

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

JointFiller 45 is a mixture of following compound and nonhazardous additives

Chemical Name CAS Number Concentration Hazardous
Calcium sulphate EC: 231-900-3 7778-18-9 55 - 65% Yes

Please consider the maximum allowed workplace concentration values for these components in Section 8.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Ensure supply of fresh air. In case of shortage of breath, provide oxygen. If unconscious place in recovery position and seek medical advice

Skin contact

Wash off immediately with soap and water. When needed use skin crème. In case of skin irritation contact a dermatologist

Eye contact

Remove contact lenses, irrigate copiously with clean, fresh water or using a flask containing sterile sodium chloride solution for at least 15 minutes, holding the eyelids apart. At any times seek medical advice by an oculist.

Ingestion

Drink plenty of water and seek medical advice.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Adjust to surrounding.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid contact with eyes and skin. Follow protective measures given in Section 7 and 8.

Environmental

Do not discharge into drains/surface waters/groundwater.

Cleanup methods

Take up spilled product in dry condition.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with skin and eyes. Keep container tightly closed to avoid dust.

Storage

Store in dry condition and avoid humidity. Seal open bags. Keep only in the original container. Avoid container of light metal.

Fire prevention

Keep away from sources of ignition - refrain from smoking.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

When an irritation has to be expected, use protective gloves. Design operations thus to avoid permanent use of protective gloves.

Eyes

With risks of spills, tightly fitting safety glasses (EN 166).

Respiratory

Use dusk masks in dusty or insufficiently ventilated condition.

Skin/Body

Standard work wear.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Metal Corrosion
---
Solidification Point
---
Freezing Point
---
Relative Evaporation Rate
---
Decomposition Temperature
About 140 °C (In CaSO₄ x ½ H₂O and H₂O); About 700 °C (In CaSO₄ and H₂O); About 1000 °C (In CaO and SO₃)
Physical State Data
solid
State Under Standard Conditions
---
Bulk Density
Approx. 900 kg/m³
Vapor Density
---
Flash Point
---
Cloud Point
---
Kinematic Viscosity
---
Odor Threshold
---
Density
---
Molecular Weight
---
Odor
Odourless
Auto Ignition Temperature
---
Physical State
Powder
Vapor Pressure
---
Colour
Off-white - light grey
Flammability
---
Crystallisation Point
---
Voc Content
---
Dynamic Viscosity
---
Melting Point
---
Explosive Limits
---
Lower Explosive Limit
---
Ph
Approx. 7
Boiling Point
---
Softening Point
---
Colour Intensity
---
Upper Explosive Limit
---
Solubility
---
Partition Coefficient
---
Appearance
Powder
Solubility In Water
Hardly soluble, 4 g/L
Solubility In Fat
---
Evaporation Rate
---
Properties Status
---
Form
---
Relative Density
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stabile under normal ambient and anticipated storage and handling conditions of temperature and pressure.

Reactivity

No materials known

Hazardous reactions

Mixing with an aqueous solution of sodium carbonate will result in the formation of carbon dioxide.

Avoid

Stable under the conditions recommended for storage in Section 7.

Incompatible

None known.

Decomposition

Decomposition takes place from temperatures above 1450 °C in CaO and SO₃.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Waste Codes

31438 Gypsum-based construction material national code
1708 gypsum-based construction material EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Not to apply
Shipping Name
Not to apply
Transport Class
Not to apply
Packing Group
Not to apply
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Gyproc JointFiller 45?

The signal word is no signal word.

What is the physical form of Gyproc JointFiller 45?

Gyproc JointFiller 45 is a powder appearing as powder with off-white - light grey color. It has odourless odor.

What is Gyproc JointFiller 45 used for?

Gypsum-based jointfiller for interior use.