NextSDS Logo
Safety Data Sheet EN

POWER CLEAN PRO

How compliant is your chemical safety?

Free 2-minute compliance assessment

Check Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
POWER CLEAN PRO
Product Code
BDS001838AE

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Cleaners - Heavy duty

Manufacturers & Suppliers

CRC Industries Europe bvba logo

CRC Industries Europe bvba

undefined

Touwslagerstraat 1 9240 Zele Belgium

www.crcind.com

Emergency Contacts

Emergency Contact

+32(0)52/45.60.11

office hours

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Aerosol Cat. 1 H222
Aerosol Cat. 1 H229
Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319
STOT SE Cat. 3 H336
Aquatic Chronic Cat. 2 H411

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

GHS09 - Environmental hazard

GHS09

Hazard Statements

H222 Extremely flammable aerosol.
H229 Pressurized container: May burst if heated.
H315 Causes skin irritation.
H319 Causes serious eye irritation.
H336 May cause drowsiness or dizziness.
H411 Toxic to aquatic life with long lasting effects.

Precautionary Statements

P102 Keep out of reach of children.
P210 Keep away from heat/sparks/open flames/hot surfaces. - No smoking.
P211 Do not spray on an open flame or other ignition source.
P251 Pressurised container: Do not pierce or burn, even after use.
P261 Avoid breathing mist/vapours.
P271 Use only outdoors or in a well-ventilated area.
P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50C/122F.
P501 Dispose of contents/container (in accordance with related regulations).

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Hydrocarbons, C6-C7, n-alkanes,isoalkanes,cyclics,< 5% n-hexane --- 25 - 50% Yes
Hydrocarbons, C7, n-alkanes,isoalkanes, cyclic --- 25 - 50% Yes
Acetone EC: 200-662-2 67-64-1 5 - 10% Yes
5% CO2 IN AIR, HIGH LEVEL CALIBRANT GAS EC: 204-696-9 124-38-9 5 - 10% Yes
Propaan-2-ol; Isopropylalcohol; Isopropanol EC: 200-661-7 67-63-0 5 - 10% Yes

Notes

The full text for all H-statements is displayed in section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. Call a poison centre or doctor/physician if you feel unwell.

Skin contact

Remove contaminated clothing. Wash with plenty of soap and water. If skin irritation occurs: Get medical advice/attention. Wash contaminated clothing before reuse.

Symptoms: Skin irritation. May cause redness and pain.

Eye contact

Immediately flush eyes with plenty of water for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Get medical attention if irritation develops and persists.

Symptoms: Severe eye irritation. Symptoms may include stinging, tearing, redness, swelling, and blurred vision.

Ingestion

In the unlikely event of swallowing contact a physician or poison control centre. Rinse mouth.

Symptoms: Nausea, vomiting.

Immediate Medical Attention

Provide general supportive measures and treat symptomatically. Keep victim under observation. Symptoms may be delayed.

Medical Treatment

Provide general supportive measures and treat symptomatically. Keep victim under observation.

Related Substances

Similar chemicals with comparable safety profiles

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level. Provide eyewash station and safety shower.

Hands

When handling the product wear chemical-resistant gloves (standard EN 374). The breakthrough time of the glove should be longer than the total duration of product use. If work lasts longer than the breakthrough time, gloves should be changed part-way through. For prolonged or repeated skin contact use suitable protective gloves. Suitable gloves can be recommended by the glove supplier. Full contact: Glove material: Neoprene. Use gloves with breakthrough time of 480 minutes. Minimum glove thickness 0.38 mm.

Eyes

Use eye protection conforming to EN 166.

Respiratory

Chemical respirator with organic vapour cartridge and full facepiece. (Filter type AX)

Skin/Body

Wear appropriate chemical resistant clothing.

Environmental

Inform appropriate managerial or supervisory personnel of all environmental releases. Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. Fume scrubbers, filters or engineering modifications to the process equipment may be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Lower Explosive Limit
2.5 % estimated
Colour
Colourless.
Form
Aerosol
Solubility In Water
Insoluble in water
Vapor Density
3
Relative Density
0.71 g/cm3
Colour Intensity
---
Decomposition Temperature
Not available.
Odor Threshold
Not available.
Explosive Limits
---
Molecular Weight
---
Solidification Point
---
Kinematic Viscosity
---
Density
---
Bulk Density
---
Evaporation Rate
---
Properties Status
---
State Under Standard Conditions
---
Melting Point
-94.7 C (-138.5 F) estimated
Odor
Solvent.
Voc Content
685 g/l
Solubility In Fat
---
Metal Corrosion
---
Softening Point
---
Auto Ignition Temperature
- 200 C (> 392 F)
Freezing Point
-94.7 C (-138.5 F) estimated
Physical State Data
liquid
Vapor Pressure
Not available.
Flammability
Not available.
Flash Point
-26.0 C (-14.8 F)
Dynamic Viscosity
---
Boiling Point
56 - 99 C (132.8 - 210.2 F)
Appearance
---
Cloud Point
---
Physical State
Liquid.
Upper Explosive Limit
12.8 % estimated
Relative Evaporation Rate
2.8 (Ether=1)
Partition Coefficient
BLANK
Ph
Not applicable.
Solubility
---
Crystallisation Point
---
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1950
Shipping Name
AEROSOLS
Transport Class
2.1
Packing Group
Not applicable
ADR

Read safety instructions, SDS and emergency procedures before handling.

IMDG

Read safety instructions, SDS and emergency procedures before handling.

IATA

Read safety instructions, SDS and emergency procedures before handling.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for POWER CLEAN PRO?

The signal word is danger.

What is the physical form of POWER CLEAN PRO?

POWER CLEAN PRO is a liquid. with colourless. color. It has solvent. odor.

What is POWER CLEAN PRO used for?

Cleaners - Heavy duty

What are the hazard statements for POWER CLEAN PRO?

This substance has 6 hazard statements:

  • H222: Extremely flammable aerosol.
  • H229: Pressurized container: May burst if heated.
  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.
  • H336: May cause drowsiness or dizziness.
  • H411: Toxic to aquatic life with long lasting effects.

What is the melting point of POWER CLEAN PRO?

The melting point is -94.7 C (-138.5 F) estimated and the boiling point is 56 - 99 C (132.8 - 210.2 F).

Compliance Scan

Free compliance check