Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- POWER CLEAN PRO
- Product Code
- BDS001838AE
- Synonyms
- None.
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Cleaners - Heavy duty
Uses advised against
None known.
Manufacturers & Suppliers
CRC Industries Europe bvba
manufacturer
Touwslagerstraat 1, 9240 Zele, Belgium
http://www.crcind.com
Emergency Contacts
Emergency Contact
+32(0)52/45.60.11
office hours
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
All concentrations are in percent by weight unless ingredient is a gas. Gas concentrations are in percent by volume.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrocarbons, C6-C7, n-alkanes, isoalkanes, cyclics, < 5% n-hexane | --- | 25 - 50% | Yes |
| Hydrocarbons, C7, n-alkanes, isoalkanes, cyclic | --- | 25 - 50% | Yes |
| acetone; propan-2-one; propanone EC: 200-662-2 | 67-64-1 | 5 - 10% | Yes |
| Carbon dioxide EC: 204-696-9 | 124-38-9 | 5 - 10% | Yes |
| Propan-2-ol; Isopropyl alcohol; Isopropanol EC: 200-661-7 | 67-63-0 | 5 - 10% | Yes |
Notes
The full text for all H-statements is displayed in section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to fresh air and keep at rest in a position comfortable for breathing. Call a poison centre or doctor/physician if you feel unwell.
Remove contaminated clothing. Wash with plenty of soap and water. If skin irritation occurs: Get medical advice/attention. Wash contaminated clothing before reuse.
Symptoms: Skin irritation. May cause redness and pain.
Immediately flush eyes with plenty of water for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Get medical attention if irritation develops and persists.
Symptoms: Severe eye irritation. Symptoms may include stinging, tearing, redness, swelling, and blurred vision.
In the unlikely event of swallowing contact a physician or poison control centre. Rinse mouth.
Immediate Medical Attention
Keep victim under observation.
Medical Treatment
Provide general supportive measures and treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water fog. Foam. Dry chemical powder. Carbon dioxide (CO2).
Do not use water jet as an extinguisher, as this will spread the fire.
Contents under pressure. Pressurised container may explode when exposed to heat or flame. During fire, gases hazardous to health may be formed.
Move containers from fire area if you can do so without risk. Containers should be cooled with water to prevent vapour pressure build up. For massive fire in cargo area, use unmanned hose holder or monitor nozzles, if possible. If not, withdraw and let fire burn out.
Firefighter Protection
Firefighters must use standard protective equipment including flame retardant coat, helmet with face shield, gloves, rubber boots, and in enclosed spaces, SCBA.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Stop leak if you can do so without risk. Move the cylinder to a safe and open area if the leak is irreparable. Keep unnecessary personnel away.
Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to remove residual contamination.
Avoid release to the environment. Inform appropriate managerial or supervisory personnel of all environmental releases. Prevent further leakage or spillage if safe to do so. Avoid discharge into drains, water courses or onto the ground.
Absorb in vermiculite, dry sand or earth and place into containers. Following product recovery, flush area with water.
Materials: absorbent material (e.g. cloth, fleece), vermiculite, dry sand or earth
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Pressurised container: Do not pierce or burn, even after use. Do not use if spray button is missing or defective. Do not spray on a naked flame or any other incandescent material. Do not smoke while using or until sprayed surface is thoroughly dry. Do not cut, weld, solder, drill, grind, or expose containers to heat, flame, sparks, or other sources of ignition. All equipment used when handling the product must be grounded. Do not re-use empty containers. Avoid breathing mist/vapours. Avoid contact with eyes, skin, and clothing. Avoid prolonged exposure. Use only in well-ventilated areas. Wear appropriate personal protective equipment. Avoid release to the environment. Observe good industrial hygiene practices.
Pressurized container: Protect from sunlight and do not expose to temperatures exceeding 50°C. Do not puncture, incinerate or crush. Do not handle or store near an open flame, heat or other sources of ignition. Store away from incompatible materials.
Observe good industrial hygiene practices.
Do not spray on a naked flame or any other incandescent material. Do not smoke while using or until sprayed surface is thoroughly dry. Do not cut, weld, solder, drill, grind, or expose containers to heat, flame, sparks, or other sources of ignition. All equipment used when handling the product must be grounded.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Good general ventilation should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level. Provide eyewash station and safety shower.
When handling the product wear chemical-resistant gloves (standard EN 374). The breakthrough time of the glove should be longer than the total duration of product use. If work lasts longer than the breakthrough time, gloves should be changed part-way through. For prolonged or repeated skin contact use suitable protective gloves. Suitable gloves can be recommended by the glove supplier. Full contact: Glove material: Neoprene. Use gloves with breakthrough time of 480 minutes. Minimum glove thickness 0.38 mm.
Use eye protection conforming to EN 166.
Chemical respirator with organic vapour cartridge and full facepiece. (Filter type AX)
Wear appropriate chemical resistant clothing.
Inform appropriate managerial or supervisory personnel of all environmental releases. Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. Fume scrubbers, filters or engineering modifications to the process equipment may be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Material is stable under normal conditions.
The product is stable and non-reactive under normal conditions of use, storage and transport.
No dangerous reaction known under conditions of normal use.
Avoid high temperatures. Avoid temperatures exceeding the decomposition temperature.
Acids. Strong oxidising agents. Aluminium. Chlorine. Isocyanates.
Carbon oxides.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Collect and reclaim or dispose in sealed containers at licensed waste disposal site.
Dispose of in accordance with local regulations. Contents under pressure. Do not puncture, incinerate or crush.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1950
- Shipping Name
- AEROSOLS
- Transport Class
- 2.1
- Packing Group
- Not applicable
Read safety instructions, SDS and emergency procedures before handling.
Read safety instructions, SDS and emergency procedures before handling.
Read safety instructions, SDS and emergency procedures before handling.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The product is classified and labelled in accordance with Regulation (EC) 1272/2008 (CLP Regulation) as amended. This Safety Data Sheet complies with the requirements of Regulation (EC) No 1907/2006, as amended.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is POWER CLEAN PRO known by?
POWER CLEAN PRO is also known as: None.
What is the hazard signal word for POWER CLEAN PRO?
The signal word is danger.
What is the physical form of POWER CLEAN PRO?
POWER CLEAN PRO is a liquid. appearing as liquid. with colourless. color. It has solvent. odor.
What is POWER CLEAN PRO used for?
Cleaners - Heavy duty
What are the hazard statements for POWER CLEAN PRO?
This substance has 6 hazard statements:
- H222: Extremely flammable aerosol.
- H229: Pressurized container: May burst if heated.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
- H411: Toxic to aquatic life with long lasting effects.
What is the melting point of POWER CLEAN PRO?
The melting point is -94.7 °C (-138.5 °F) estimated and the boiling point is 56 - 99 °C (132.8 - 210.2 °F).