NextSDS Logo
Ca

Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC.

NO SIGNAL WORD Solid Plaques SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC.

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Thermal insulation

Overview

Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC. commonly used thermal insulation.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

INSULCON B.V. company logo - Safety Data Sheet supplier organization

INSULCON B.V.

global supplier

๐Ÿ“

Zilverhoek 4, 4651 SP STEENBERGEN, The Netherlands

๐ŸŒ

NL

๐Ÿ“ž

+31 (0)167-565750

๐Ÿ“ 

+31 (0)167-566263

๐ŸŒ www.insulcon.com

KERAMAB N.V.

global supplier

๐ŸŒ

BE

๐Ÿ“ž

+ 32 (0)3 711.02.78

INSULCON GMBH

global supplier

๐ŸŒ

DE

๐Ÿ“ž

+ 49 (0) 2162 249 60-0

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

General Composition

Insulating Material

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Calciumsilicate
EC: 215-710-8
1344-95-2 50-100% โš ๏ธ Hazardous
Cellulose
EC: 232-674-9
9004-34-6 10% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Supply fresh air; consult doctor in case of symptoms.

๐Ÿ–๏ธ Skin Contact

Wash with soap and water.

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse out mouth and then drink plenty of water. in case of persistent symptoms consult doctor.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Solid Plaques
Critical Property
๐Ÿ“Š Physical State Data
solid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Grey
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Solid Plaques
๐Ÿ‘ƒ Odor
Odourless
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
9.9 (Dispersion)
๐ŸงŠ Melting Point
1500
Critical Property
๐Ÿ’จ Boiling Point
Not applicable
Critical Property
๐Ÿ”ฅ Flash Point
Not applicable
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
0.189 - 0.374 g/cm3
Critical Property
๐Ÿ”ฅ Flammability
Product is not selfigniting
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Product is not selfigniting
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
Not miscible or difficult to mix
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

No further data; see item 7.

๐Ÿงค Hand Protection

Protective gloves. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The glove material has to be impermeable and resistant to the product / the substance / the preparation. Check the permeability prior to each anewed use of the glove. To avoid skin problems reduce the wearing of gloves to the required minimum. Due to missing tests no recommendation to the glove material can be given for the product / the preparation / the chemical mixture. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material cannot be calculated in advance and has therefore to be checked prior to the application. Protective gloves should be replaced at first signs of wear. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

๐Ÿ‘๏ธ Eye Protection

Safety glasses

๐Ÿ˜ท Respiratory Protection

Use breathing protection in case of dust formation. If all workplace limits are observed and good ventilation is ensured, no special precautions necessary.

๐Ÿฆบ Skin/Body Protection

Protective clothing should be selected specifically for the working place.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC.?

The signal word for this substance is "no signal word".

What is the physical form of Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC.?

Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC. is a solid plaques with grey color. It has odourless odor.

What is Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC. used for?

Thermal insulation

What is the melting point of Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC.?

The melting point is 1500 and the boiling point is Not applicable.