Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Thermal insulation
Manufacturers & Suppliers
INSULCON B.V.
P.O. Box 134, 4650 AC STEENBERGEN, The Netherlands; Zilverhoek 4, 4651 SP STEENBERGEN
+31 (0)167-565750
http://www.insulcon.com
KERAMAB N.V.
Belgium
+32 (0)3 711.02.78
INSULCON GMBH
Germany
+49 (0) 2162 249 60-0
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of symptoms.
Wash with soap and water.
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
Rinse out mouth and then drink plenty of water. in case of persistent symptoms consult doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Product does not burn – take extinguishing measures according to fire conditions.
Carbon monoxide (CO) and Carbon dioxide (CO₂).
Firefighter Protection
Wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Damp down dust with water spray jet.
Collect mechanically.
Related Products
Similar products with comparable safety profiles
Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC
---
Alpacon Descalant III
UFI: PPK3-T0NY-C00D-NGSV
Alpacon multi CIP II
---
INDOPOL® H-25, H-25 SR, H-50, H-100, H-100 CP, H-300, H-300 C, H-300 CP, H-1200, H1200 CP
---
INDOPOL® H-25, H-25 SR, H-50, H-100, H-100 CP, H-300, H-300 C, H-300 CP, H-1200, H1200 CP
CAS: 9003-29-6, 9044-17-1
CERECLOR™ S40 / S45 / S50 / S52 / S52HV / S52SS / 51L / S54 / S55 / S56 / S58 / S60 / S63
---
INDOPOL® H-1500, H-1900, H-2100, H-6000, H-18000
---
CAFLON BICO TA44
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not breathe dust. Make sure that all applicable workplace limits are observed. Avoid contact with eyes. Avoid prolonged or repeated skin contact.
Store under dry conditions. Observe all local and national regulations for storage of water polluting products.
The product is not flammable
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
If all workplace limits are observed and good ventilation is ensured, no special precautions necessary. No further data; see item 7.
Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The glove material has to be impermeable and resistant to the product / the substance / the preparation. Check the permeability prior to each anewed use of the glove. To avoid skin problems reduce the wearing of gloves to the required minimum. Due to missing tests no recommendation to the glove material can be given for the product / the preparation / the chemical mixture. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material cannot be calculated in advance and has therefore to be checked prior to the application. Protective gloves should be replaced at first signs of wear. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
Safety glasses
Use breathing protection in case of dust formation. If all workplace limits are observed and good ventilation is ensured, no special precautions necessary.
Protective clothing should be selected specifically for the working place.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications
No dangerous reactions known
No decomposition if used according to specifications
Acids
Carbon monoxide (CO) and Carbon dioxide (CO²)
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Disposal must be made according to official regulations.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The product is not subject to classification according to the calculation methods of the 'General Classification Guideline for Preparations of the EC' as issued in the last version.
Safety phrases: 22 Do not breathe dust. 25 Avoid contact with eyes.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC?
The signal word is no signal word.
What is the physical form of Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC?
Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC is a solid appearing as plaques with grey color. It has odourless odor.
What is the solubility of Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC?
Not miscible or difficult to mix
What is Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC used for?
Thermal insulation
What is the melting point of Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC?
The melting point is 1500°C and the boiling point is Not applicable.