NextSDS Logo
Safety Data Sheet EN

Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Thermal insulation

Manufacturers & Suppliers

INSULCON B.V. logo

INSULCON B.V.

P.O. Box 134, 4650 AC STEENBERGEN, The Netherlands; Zilverhoek 4, 4651 SP STEENBERGEN

+31 (0)167-565750

http://www.insulcon.com

K

KERAMAB N.V.

Belgium

+32 (0)3 711.02.78

I

INSULCON GMBH

Germany

+49 (0) 2162 249 60-0

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Insulating Material

Chemical Name CAS Number Concentration Hazardous
Calciumsilicate EC: 215-710-8 1344-95-2 50 - 100% No
Cellulose EC: 232-674-9 9004-34-6 10% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of symptoms.

Skin contact

Wash with soap and water.

Eye contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.

Ingestion

Rinse out mouth and then drink plenty of water. in case of persistent symptoms consult doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Product does not burn – take extinguishing measures according to fire conditions.

Specific hazards

Carbon monoxide (CO) and Carbon dioxide (CO₂).

Firefighter Protection

Wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Damp down dust with water spray jet.

Cleanup methods

Collect mechanically.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not breathe dust. Make sure that all applicable workplace limits are observed. Avoid contact with eyes. Avoid prolonged or repeated skin contact.

Storage

Store under dry conditions. Observe all local and national regulations for storage of water polluting products.

Fire prevention

The product is not flammable

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

If all workplace limits are observed and good ventilation is ensured, no special precautions necessary. No further data; see item 7.

Hands

Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The glove material has to be impermeable and resistant to the product / the substance / the preparation. Check the permeability prior to each anewed use of the glove. To avoid skin problems reduce the wearing of gloves to the required minimum. Due to missing tests no recommendation to the glove material can be given for the product / the preparation / the chemical mixture. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material cannot be calculated in advance and has therefore to be checked prior to the application. Protective gloves should be replaced at first signs of wear. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Safety glasses

Respiratory

Use breathing protection in case of dust formation. If all workplace limits are observed and good ventilation is ensured, no special precautions necessary.

Skin/Body

Protective clothing should be selected specifically for the working place.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Molecular Weight
---
Lower Explosive Limit
---
Freezing Point
---
Metal Corrosion
---
Relative Evaporation Rate
---
Softening Point
---
Auto Ignition Temperature
Product is not selfigniting
Relative Density
---
Vapor Density
---
Physical State
Solid
Density
0.189 – 0.374 g/cm³
Voc Content
---
Physical State Data
solid
Bulk Density
---
Crystallisation Point
---
Dynamic Viscosity
---
Ph
9.9 (Dispersion)
Solubility In Fat
---
Properties Status
---
Boiling Point
Not applicable
Partition Coefficient
---
State Under Standard Conditions
---
Upper Explosive Limit
---
Flammability
Product is not selfigniting
Solubility In Water
Not miscible or difficult to mix
Cloud Point
---
Flash Point
Not applicable
Decomposition Temperature
---
Vapor Pressure
---
Solubility
Not miscible or difficult to mix
Kinematic Viscosity
---
Explosive Limits
---
Odor Threshold
---
Melting Point
1500°C
Odor
Odourless
Colour Intensity
---
Colour
Grey
Appearance
Plaques
Evaporation Rate
---
Form
Solid Plaques
Solidification Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications

Hazardous reactions

No dangerous reactions known

Avoid

No decomposition if used according to specifications

Incompatible

Acids

Decomposition

Carbon monoxide (CO) and Carbon dioxide (CO²)

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Disposal must be made according to official regulations.

Waste Codes

Not specified Waste disposal key numbers from EWC have to be assigned depending on origin and processing. EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The product is not subject to classification according to the calculation methods of the 'General Classification Guideline for Preparations of the EC' as issued in the last version.

Chemical Safety Assessment Not performed

Safety phrases: 22 Do not breathe dust. 25 Avoid contact with eyes.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC?

The signal word is no signal word.

What is the physical form of Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC?

Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC is a solid appearing as plaques with grey color. It has odourless odor.

What is the solubility of Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC?

Not miscible or difficult to mix

What is Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC used for?

Thermal insulation

What is the melting point of Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC?

The melting point is 1500°C and the boiling point is Not applicable.

Compliance Scanner

Scan your compliance