NextSDS Logo
Safety Data Sheet EN

Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Mineral thermal insulation panels

Manufacturers & Suppliers

INSULCON B.V. logo

INSULCON B.V.

Zilverhoek 4, 4651 SP STEENBERGEN

+31 (0)167-565750

http://www.insulcon.com

I

INSULCON N.V.

+32 (0)3 711 02 78

I

INSULCON GMBH

+49 (0)2131 408548-0

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Calciumsilicate, Cellulos

Chemical Name CAS Number Concentration Hazardous
N/A --- --- No
N/A --- --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

(Dust) Provide fresh air.

Skin contact

Wash with plenty of soap and water.

Eye contact

(Dust) Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Ingestion

No exposure expected.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

water, foam, alcohol resistant foam, fire extinguishing powder

Unsuitable media

water jet

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Ventilate affected area. Wearing of suitable protective equipment (including personal protective equipment referred to under Section 8 of the safety data sheet) to prevent any contamination of skin, eyes and personal clothing.

Environmental

Keep away from drains, surface and ground water. Retain contaminated washing water and dispose of it.

Cleanup methods

Take up mechanically.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not breathe dust. Preventive skin protection (barrier creams/ointments) is recommended.

Storage

Store in a dry place. Keep away from food, drink and animal feeding stuffs.

Hygiene

Do not eat, drink and smoke in work areas. Wash hands after use. Preventive skin protection (barrier creams/ointments) is recommended. Remove contaminated clothing and protective equipment before entering eating areas.

Fire prevention

Use local and general ventilation.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

General ventilation.

Hands

Wear suitable gloves (Substance, Leather)

Eyes

Dust-Development: Use safety goggle with side protection.

Respiratory

In case of inadequate ventilation wear respiratory protection. Particulate filter device (EN 143).

Environmental

Keep away from drains, surface and ground water.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Relative Density
---
Partition Coefficient
not relevant (inorganic)
Melting Point
1500 °C
Decomposition Temperature
not relevant
Vapor Density
---
Physical State Data
solid
Vapor Pressure
not determined
Ph
9 – 11 (water: 100 % / 20 °C)
Appearance
solid (panels)
Solubility In Fat
---
Boiling Point
not determined
Physical State
solid (panels)
Voc Content
---
Evaporation Rate
---
Dynamic Viscosity
---
Colour Intensity
---
Odor Threshold
---
Molecular Weight
---
Cloud Point
---
Flash Point
not applicable
Relative Evaporation Rate
---
Metal Corrosion
---
Softening Point
---
Colour
light grey
Solidification Point
---
Form
---
Density
150 – 550 kg/m³ at 20 °C
Upper Explosive Limit
not determined
Solubility In Water
insoluble
Kinematic Viscosity
---
Crystallisation Point
---
Bulk Density
---
Lower Explosive Limit
not determined
Flammability
non-combustible
Properties Status
---
State Under Standard Conditions
---
Odor
odourless
Solubility
---
Freezing Point
1500 °C
Explosive Limits
---
Auto Ignition Temperature
not relevant
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The material is stable under normal ambient and anticipated storage and handling conditions of temperature and pressure. See below "Conditions to avoid".

Reactivity

This material is not reactive under normal ambient conditions.

Hazardous reactions

No known hazardous reactions.

Avoid

There are no specific conditions known which have to be avoided.

Incompatible

There is no additional information.

Decomposition

Reasonably anticipated hazardous decomposition products produced as a result of use, storage, spill and heating are not known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Dispose of contents/container in accordance with local/regional/national/international regulations.

Disposal

Dispose of contents/container in accordance with local/regional/national/international regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC?

The signal word is no signal word.

What is the physical form of Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC?

Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC is a solid (panels) appearing as solid (panels) with light grey color. It has odourless odor.

What is Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC used for?

Mineral thermal insulation panels

What is the melting point of Calcon 900 SC, Calcon 1000 SC, Calcon 1100 SC?

The melting point is 1500 °C and the boiling point is not determined.

Compliance Scanner

Scan your compliance