NextSDS Logo
Safety Data Sheet EN

REFRACAST MW 1300

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
REFRACAST MW 1300

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Refractory lining for industrial applications.

Manufacturers & Suppliers

R

Refratechnik Steel GmbH

manufacturer

Am Seestern 5, 40547 Düsseldorf

+49 211 58 58 0

Emergency Contacts

Emergency Contact

+ 49 171 8120436

during the regular office hours

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Refractory product based on light fireclay

Chemical Name CAS Number Concentration Hazardous
clays, flint, calcined 93821-35-3 25 - 80% No
calcium aluminate 65997-16-2 10 - 35% No

For the wording of the listed hazard phrases refer to section 16.

Notes

Dangerous components: Void

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of inhalation of dust remove to fresh air. Drink water and blow nose.

Skin contact

After skin contact with the dust wash with plenty of warm water and soap.

Eye contact

After contact with dust flush open eyes with running water during several minutes. If the trouble persists seek medical advice.

Ingestion

After swallowing dust, rinse mouth and drink plenty of water.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use fire extinguishing methods suitable to surrounding conditions.

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Pick up mechanically, dust-free, e.g. by moistening with water

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Prevent formation of dust. Have ready for use an eye wash right next to the working place.

Storage

Do not store near to a fire or other heat sources. Store in dry conditions.

Hygiene

Have ready for use an eye wash right next to the working place.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

In case of work with machines (e.g. cutting and grinding machines) ensure extraction system or sufficient ventilation.

Hands

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Tightly sealed goggles

Respiratory

Filter type P1 - P3, depending on the dust concentration.

Skin/Body

Tight-fitting protective work clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
Light brown
Colour Intensity
---
Form
Dry mix of coarse and fine fractions
Odor
Specific type
Odor Threshold
Not determined
Ph
11 (1 kg/l)
Melting Point
Undetermined
Boiling Point
Undetermined
Flash Point
Not applicable
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not applicable.
Vapor Pressure
Not applicable
Vapor Density
Not applicable
Relative Density
Not determined
Bulk Density
---
Density
See technical data sheet.
Flammability
Not determined
Upper Explosive Limit
Not determined
Lower Explosive Limit
Not determined
Explosive Limits
---
Auto Ignition Temperature
Product is not selfigniting.
Decomposition Temperature
Not determined
Solubility
---
Partition Coefficient
Not determined
Solubility In Water
Soluble.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Not applicable
Kinematic Viscosity
Not applicable
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No decomposition if used according to specifications.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Aquatic toxicity: No further relevant information available.

No further relevant information available regarding aquatic toxicity.

12.2 Persistence and degradability

No further relevant information available.

No further relevant information available.

12.3 Bioaccumulative potential

No further relevant information available.

12.4 Mobility in soil

No further relevant information available.

12.5 Results of PBT and vPvB assessment

PBT: Not applicable vPvB: Not applicable

The substance is not considered to be PBT or vPvB.

12.6 Endocrine disrupting properties

The product does not contain substances with endocrine disrupting properties.

The product does not contain substances with endocrine disrupting properties.

12.7 Other adverse effects

12.7 Other adverse effects Additional ecological information: General notes: Water hazard class 1 (German Regulation) (Self-assessment): slightly hazardous for water Do not allow undiluted product or large quantities of it to reach ground water, water course or sewage system.

Water hazard class 1 (slightly hazardous for water). Prevent entry into water systems.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Disposal must be made according to official regulations.

Disposal

Before elimination: Check whether the product has absorbed further substances during its use, and therefore has to be assigned to another waste group than initially recommended.

Waste Codes

16 11 03* other linings and refractories from metallurgical processes containing hazardous substances EWC
16 11 04 other linings and refractories from metallurgical processes other than those mentioned in 16 11 03 EWC
17 01 07 mixtures of concrete, bricks, tiles and ceramics other than those mentioned in 17 01 06 EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for REFRACAST MW 1300?

The signal word is no signal word.

What is the physical form of REFRACAST MW 1300?

REFRACAST MW 1300 is a solid with light brown color. It has specific type odor.

What is REFRACAST MW 1300 used for?

Refractory lining for industrial applications.

What is the melting point of REFRACAST MW 1300?

The melting point is Undetermined and the boiling point is Undetermined.