NextSDS Logo
Al

Aluminium potassium sulfate dodecahydrate for analysis EMSURE ACS,Reag. Ph Eur

NO SIGNAL WORD solid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Aluminium potassium sulfate dodecahydrate for analysis EMSURE ACS,Reag. Ph Eur
Product Code
101047

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Reagent for analysis

Overview

Aluminium potassium sulfate dodecahydrate for analysis EMSURE ACS,Reag. Ph Eur commonly used reagent for analysis.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Merckgroup.com

manufacturer

Merck Chemicals Ltd

national supplier

๐Ÿ“

Boulevard Industrial Park * Padge Road * Beeston * Nottingham * NG9 2JR

๐ŸŒ

GB

๐Ÿ“ž

01159 430840

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+49 (0) 6151 722440

๐ŸŒ

DE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Substance

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Aluminium potassium sulfate dodecahydrate
EC: 233-141-3
N/A Not specified โœ“ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

fresh air.

๐Ÿ–๏ธ Skin Contact

Take off immediately all contaminated clothing. Rinse skin with water/ shower.

๐Ÿ‘๏ธ Eye Contact

rinse out with plenty of water.

๐Ÿฝ๏ธ Ingestion/Swallowing

make victim drink water (two glasses at most). Consult doctor if feeling unwell.

Symptoms:

only slightly absorbable via the gastrointestinal tract. Serious disorders in man (from about 4000 mg aluminium up): phosphate metabolism, calcium metabolism.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
solid
Critical Property
๐Ÿ“Š Physical State Data
solid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
colourless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
solid
๐Ÿ‘ƒ Odor
odourless
๐Ÿ“Š Odor Threshold
not applicable
๐Ÿงช Ph
3.0 - 3.5 at 100 g/l 20 C
๐ŸงŠ Melting Point
92.5 C
Critical Property
๐Ÿ’จ Boiling Point
No information available.
Critical Property
๐Ÿ”ฅ Flash Point
does not flash
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
No information available.
๐Ÿ’จ Vapor Pressure
No information available.
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
No information available.
๐Ÿ“Š Bulk Density
ca.900 kg/m
โš–๏ธ Density
1.75 g/cm at 20 C
Critical Property
๐Ÿ”ฅ Flammability
The product is not flammable.
๐Ÿ“Š Upper Explosive Limit
not applicable
๐Ÿ“Š Lower Explosive Limit
not applicable
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
No information available.
๐Ÿ“Š Decomposition Temperature
60 - 200 C Elimination of water of crystallisation
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
No information available.
๐Ÿ“Š Solubility In Water
139 g/l at 20 C
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
No information available.
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.

๐Ÿงค Hand Protection

full contact: Glove material: Nitrile rubber, Glove thickness: 0.11 mm, Break through time: - 480 min. splash contact: Glove material: Nitrile rubber, Glove thickness: 0.11 mm, Break through time: - 480 min. The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 741 Dermatril L (full contact), KCL 741 Dermatril L (splash contact). The breakthrough times stated above were determined by KCL in laboratory tests acc. to EN374 with samples of the recommended glove types. This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g., KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

๐Ÿ‘๏ธ Eye Protection

Safety glasses

๐Ÿ˜ท Respiratory Protection

required when dusts are generated. Recommended Filter type: Filter P 1 (acc. to DIN 3181) for solid particles of inert substances. The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

๐Ÿฆบ Skin/Body Protection

Protective clothing needs to be selected specifically for the workplace, depending on concentrations and quantities of the hazardous substances handled. The chemical resistance of the protective equipment should be enquired at the respective supplier.

๐ŸŒ Environmental Exposure Controls

Do not empty into drains.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Aluminium potassium sulfate dodecahydrate for analysis EMSURE ACS,Reag. Ph Eur?

The signal word for this substance is "no signal word".

What is the physical form of Aluminium potassium sulfate dodecahydrate for analysis EMSURE ACS,Reag. Ph Eur?

Aluminium potassium sulfate dodecahydrate for analysis EMSURE ACS,Reag. Ph Eur is a solid with colourless color. It has odourless odor.

What is Aluminium potassium sulfate dodecahydrate for analysis EMSURE ACS,Reag. Ph Eur used for?

Reagent for analysis

What is the melting point of Aluminium potassium sulfate dodecahydrate for analysis EMSURE ACS,Reag. Ph Eur?

The melting point is 92.5 C and the boiling point is No information available..