NextSDS Logo
SP

SPECTRA Differentiator

DANGER Liquid SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
SPECTRA Differentiator
Product Code
3801592; 3801587; 3801597

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
H&E Staining System optimized for use with the SPECTRA Staining Instrument
Uses Advised Against
Other uses

Overview

SPECTRA Differentiator commonly used h&e staining system optimized for use with the spectra staining instrument.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Flam. Liq. Category 2
Skin Irrit. Category 2
Eye Irrit. Category 2A
STOT SE Category 1

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H225: Highly flammable liquid and vapor
  • H315: Causes skin irritation
  • H319: Causes serious eye irritation
  • Causes damage to organs

Precautionary Statements

  • Keep away from heat, sparks, open flames, hot surfaces. No smoking.
  • Keep container tightly closed
  • Ground/Bond container and receiving equipment
  • Use explosion-proof equipment
  • Use only non-sparking tools
  • Take precautionary measures against static discharge
  • Do not breathe mist/vapours/spray.
  • Wash thoroughly after handling
  • Do not eat, drink or smoke when using this product
  • Wear protective gloves/protective clothing/eye protection/face protection.
  • IF ON SKIN: Wash with plenty of soap and water
  • If on skin (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower
  • If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing
  • If exposed: Call a poison center/doctor
  • If skin irritation occurs: Get medical advice/attention
  • If eye irritation persists: Get medical advice/attention
  • Take off contaminated clothing and wash it before reuse
  • In case of fire: Use dry chemical, foam, or water spray for extinction.
  • Store in a well-ventilated place. Keep cool
  • Store locked up
  • Dispose of contents/container in accordance with all local/regional/national/international regulations
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Leica Biosystems Richmond, Inc company logo - Safety Data Sheet supplier organization

Leica Biosystems Richmond, Inc

undefined

5205 Route 12 Richmond, IL 60071 - USA

US

844-534-2262

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

ChemTrec

800-424-9300

US

Emergency Contact

+1 703-527-3887

US

call collect

Australia 24 Hr Poisons Information Centre

13 11 26

AU

24 Hr

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Ethanol 64-17-5 20% Hazardous
acetic acid 64-19-7 15% Hazardous
methanol 67-56-1 5% Hazardous
Isopropanol 67-63-0 5% Hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Remove person to fresh air and keep comfortable for breathing.

Skin Contact

Rinse skin with water/shower. Remove/Take off immediately all contaminated clothing.

Eye Contact

Rinse eyes with water as a precaution.

Ingestion/Swallowing

Rinse mouth. Call a poison center/doctor/physician if you feel unwell.

Immediate Medical Attention Required

Treat symptomatically.

Medical Treatment

Treat symptomatically.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State Data
liquid
Colour Intensity
Not available
Melting Point
Not applicable
Critical Property
Cloud Point
Not available
Solubility In Water
Not available
Dynamic Viscosity
No data available
Vapor Pressure
No data available
Flash Point
52 °F /11 °C
Critical Property
Lower Explosive Limit
Not available
Crystallisation Point
Not available
Ph
4 - 5
Flammability
Not applicable.
Upper Explosive Limit
Not available
Bulk Density
Not available
Partition Coefficient
No data available
Density
0.79
Critical Property
Colour
Colorless
Solubility In Fat
Not available
Metal Corrosion
Not available
Voc Content
Not available
Explosive Limits
Not available
Softening Point
Not available
Molecular Weight
Not available
Evaporation Rate
Not available
Physical State
Liquid
Critical Property
Odor
Alcohol odour
Kinematic Viscosity
No data available
Appearance
Not available
Properties Status
Not available
Decomposition Temperature
No data available
Auto Ignition Temperature
No data available
Relative Density
No data available
Solubility
No data available
Relative Evaporation Rate
No data available
Vapor Density
Not available
State Under Standard Conditions
Not available
Form
Not available
Boiling Point
No data available
Critical Property
Solidification Point
Not available
Odor Threshold
No data available
Freezing Point
No data available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Ensure good ventilation of the work station.

Hand Protection

Protective gloves

Eye Protection

Safety glasses

Respiratory Protection

None needed with adequate ventilation. If the occupational exposure limit is exceeded, use an approved organic vapor respirator. Selection of respiratory protection depends on the contaminant type, form, and concentration. Select in accordance with OSHA 1910.134 or other applicable regulations and good industrial hygiene practice.

Skin/Body Protection

Wear suitable protective clothing

Environmental Exposure Controls

Avoid release to the environment.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

UN1987

Proper Shipping Name

Alcohols, n.o.s. (Ethanol, Methanol)

Transport Hazard Class

3

Packing Group

II

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for SPECTRA Differentiator?

The signal word for this substance is "danger".

What is the physical form of SPECTRA Differentiator?

SPECTRA Differentiator is a liquid with colorless color. It has alcohol odour odor.

What is the solubility of SPECTRA Differentiator?

No data available

What is SPECTRA Differentiator used for?

H&E Staining System optimized for use with the SPECTRA Staining Instrument

What are the hazard statements for SPECTRA Differentiator?

This substance has 4 hazard statements: H225: Highly flammable liquid and vapor H315: Causes skin irritation H319: Causes serious eye irritation Causes damage to organs

What is the melting point of SPECTRA Differentiator?

The melting point is Not applicable and the boiling point is No data available.