NextSDS Logo
Ta

TaqMan Gene Expression Assay, INV, S

DANGER liquid SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
TaqMan Gene Expression Assay, INV, S
Product Code
4331182

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
For research use only
Uses Advised Against
Not for consumer use.

Overview

TaqMan Gene Expression Assay, INV, S is a liquid substance commonly used for research use only.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Carc. Category 2
Repr. Category 1B
STOT RE Category 2

GHS Hazard Pictograms & Safety Symbols

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H351: Suspected of causing cancer if swallowed
  • H360: May damage fertility or the unborn child if swallowed
  • H373: May cause damage to organs through prolonged or repeated exposure

Precautionary Statements

  • P201: Obtain special instructions before use
  • P202: Do not handle until all safety precautions have been read and understood
  • P260: Do not breathe dust/fume/gas/mist/vapours/spray
  • P280: Wear protective gloves/protective clothing/eye protection/face protection
  • P281: Use personal protective equipment as required
  • P308 + P313: IF exposed or concerned: Get medical advice/attention
  • P314: Get medical advice/attention if you feel unwell
  • P501: Dispose of contents/ container to an approved waste disposal plant
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

LIFE TECHNOLOGIES EUROPE BV

manufacturer

KWARTSWEG 2 2665 NN BLEISWIJK

NL

31-(0)180 392 400

Life Technologies Limited

manufacturer

3 Fountain Drive Inchinnan Business Park Paisley PA4 9RF

GB

+44 (0)141 814 6100

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CHEMTREC

1-800-424-9300

US

Within the USA + Canada

CHEMTREC

+1 703-527-3887

US

Within the USA + Canada

CHEMTREC

+1 703-741-5970

Outside the USA + Canada

CHEMTREC Ireland (Dublin)

+(353)-19014670

IE

Languages: EN, GA

CHEMTREC UK (London)

+(44)-870-8200418

GB

Languages: EN

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Formamide
EC: 200-842-0
75-12-7 0.23% Hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Remove to fresh air. If not breathing, give artificial respiration. If symptoms persist, call a doctor.

Skin Contact

Wash off immediately with plenty of water for at least 15 minutes. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Immediate medical attention is required.

Eye Contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Immediate medical attention is required.

Ingestion/Swallowing

Never give anything by mouth to an unconscious person. Do not induce vomiting without medical advice. If swallowed, rinse mouth with water (only if the person is conscious).

Symptoms:

Risk of serious damage to the lungs (by aspiration). Get medical attention if symptoms occur.

Immediate Medical Attention Required

Immediate medical attention is required (for skin and eye contact). IF exposed or concerned: Get medical advice/attention. Get medical advice/attention if you feel unwell.

Medical Treatment

Treat symptomatically.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Odor
No data
Bulk Density
Not available
Crystallisation Point
Not available
Freezing Point
Not available
Vapor Density
Not available
Lower Explosive Limit
Mixture has not been tested
Physical State
liquid
Critical Property
Flammability
Mixture has not been tested
Cloud Point
Not available
Relative Density
Mixture has not been tested
Solubility In Fat
Not available
Physical State Data
liquid
Odor Threshold
Not Applicable
Vapor Pressure
No data
Voc Content
Not available
Partition Coefficient
Mixture has not been tested
Dynamic Viscosity
Not available
Density
No data
Critical Property
Molecular Weight
Not available
Auto Ignition Temperature
Mixture has not been tested
Ph
Mixture has not been tested
Explosive Limits
Not available
Colour
Not available
Solubility
Mixture has not been tested
Solidification Point
Not available
Melting Point
Mixture has not been tested
Critical Property
Kinematic Viscosity
Not available
Solubility In Water
Soluble in water
Colour Intensity
Not available
Flash Point
Mixture has not been tested
Critical Property
Upper Explosive Limit
Mixture has not been tested
Properties Status
Not available
Boiling Point
Mixture has not been tested
Critical Property
Appearance
liquid
Decomposition Temperature
No data
Form
Not available
Evaporation Rate
Mixture has not been tested
Relative Evaporation Rate
Not available
Metal Corrosion
Not available
State Under Standard Conditions
Not available
Softening Point
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Ensure adequate ventilation, especially in confined areas.

Hand Protection

Glove material:. Nitrile rubber. with thickness (mm). :5. Break through time. (hours). :>1. Recommended glove type has not been tested for use with this product. Information is based on professional knowledge.

Eye Protection

Tight sealing safety goggles.

Respiratory Protection

In case of insufficient ventilation wear respirators and components tested and approved under appropriate government standards.

Skin/Body Protection

Wear laboratory coat for body protection.

Environmental Exposure Controls

No special environmental precautions required.

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Stable under normal conditions.

Reactivity

None known.

Hazardous Reactions

Hazardous reaction has not been reported.

Conditions to Avoid

High temperature.

Incompatible Materials

oxidising agents. Acids. Bases. Sulphur trioxide. Iodine.

Hazardous Decomposition Products

Carbon monoxide. Hydrogen cyanide (hydrocyanic acid). Nitrogen oxides (NOx).

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for TaqMan Gene Expression Assay, INV, S?

The signal word for this substance is "danger".

What is the physical form of TaqMan Gene Expression Assay, INV, S?

TaqMan Gene Expression Assay, INV, S is a liquid appearing as liquid . It has no data odor.

What is the solubility of TaqMan Gene Expression Assay, INV, S?

Mixture has not been tested

What is TaqMan Gene Expression Assay, INV, S used for?

For research use only

What are the hazard statements for TaqMan Gene Expression Assay, INV, S?

This substance has 3 hazard statements: H351: Suspected of causing cancer if swallowed H360: May damage fertility or the unborn child if swallowed H373: May cause damage to organs through prolonged or repeated exposure

What is the melting point of TaqMan Gene Expression Assay, INV, S?

The melting point is Mixture has not been tested and the boiling point is Mixture has not been tested.