NextSDS Logo
Safety Data Sheet EN

Fomtec AFFF 6%

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Fomtec AFFF 6%
Product Code
10-6006-01

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Appliance protection

Uses advised against

None known.

Manufacturers & Suppliers

Dafo Fomtec AB logo

Dafo Fomtec AB

manufacturer

Box 683, SE-13526 Tyresö, Sweden

+46 8 506 405 00

http://www.fomtec.com

Emergency Contacts

The National Poisons Information Service

111

24 h service

NCEC CareChem24

+44 1273 289451

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

According to REACH Regulation (EC) No 1907/2006, as retained and amended SI 2019/758 and SI 2020/1577

Chemical Name CAS Number Concentration Hazardous
2-(2-butoxyethoxy)ethanol; diethylene glycol monobutyl ether EC: 203-961-6 112-34-5 3 - 5% Yes
Blend of Fluorinated substances C6(PFAS) 00-00-0 0.3% No
2-methylpentane-2,4-diol EC: 203-489-0 107-41-5 0.25% Yes
C6 fluorotelomer-based surfactant 00-00-0 0.25% Yes
ethanediol EC: 203-473-3 107-21-1 0.25% Yes
methanol EC: 200-659-6 67-56-1 0.05% Yes

Notes

See full text of H-phrases in section 16. Occupational exposure limits are listed in section 8, if these are available. [1] European occupational exposure limit. [3] According to UK REACH, Annex XVII, the substance is subject to restrictions.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Upon breathing difficulties or irritation of the respiratory tract: Bring the person into fresh air and stay with him/her.

Skin contact

Upon irritation: rinse with water. In the event of continued irritation, seek medical assistance.

Symptoms: irritation

Eye contact

If in eyes: Flush eyes with water or saline water (20-30 °C) for at least 5 minutes. Remove contact lenses. Seek medical assistance and continue flushing during transport.

Ingestion

If the person is conscious, rinse the mouth with water and stay with the person. Never give the person anything to drink. In case of malaise, seek medical advice immediately and bring the safety data sheet or label from the product. Do not induce vomiting, unless recommended by the doctor. Have the person lean forward with head down to avoid inhalation of or choking on vomited material.

Symptoms: malaise

Immediate Medical Attention

In case of malaise, seek medical advice immediately. Seek medical assistance and continue flushing during transport.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

The product is not flammable

Firefighter Protection

Fire fighters should wear appropriate personal protective equipment.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Ensure adequate ventilation, especially in confined areas. Contaminated areas may be slippery.

Environmental

Avoid discharge to lakes, streams, sewers, etc.

Cleanup methods

cleaning should be performed with normal cleaning agents. Avoid use of solvents.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

See section 8 "Exposure controls/personal protection" for information on personal protection.

Storage

Dry, cool and well ventilated (< 55 °C)

Hygiene

Smoking, drinking and consumption of food is not allowed in the work area.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Installation of a local exhaust system if normal air flow in the work room is not sufficient is recommended. Ensure eyewash and emergency showers are clearly marked.

Hands

Material: Vinyl/PVC, Glove thickness: 0.6 mm

Eyes

Wear safety glasses with side shields. Standards: EN166

Respiratory

No specific requirements

Skin/Body

Dedicated work clothing should be worn.

Environmental

No specific requirements.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Decomposition Temperature
Testing not relevant or not possible due to the nature of the product.
Upper Explosive Limit
Testing not relevant or not possible due to the nature of the product.
Auto Ignition Temperature
Testing not relevant or not possible due to the nature of the product.
Softening Point
Does not apply to liquids.
Lower Explosive Limit
Testing not relevant or not possible due to the nature of the product.
Relative Evaporation Rate
---
State Under Standard Conditions
---
Dynamic Viscosity
< 15 mPa.s
Flash Point
Testing not relevant or not possible due to the nature of the product.
Partition Coefficient
Testing not relevant or not possible due to the nature of the product.
Appearance
---
Bulk Density
---
Solubility In Water
Completely soluble
Ph
6.5-8.5
Colour Intensity
---
Cloud Point
---
Odor Threshold
Characteristic
Crystallisation Point
---
Explosive Limits
---
Metal Corrosion
---
Melting Point
~ -1 °C
Density
~ 1.005 g/cm³
Solubility In Fat
Testing not relevant or not possible due to the nature of the product.
Freezing Point
~ -1°C
Voc Content
---
Relative Density
---
Boiling Point
Testing not relevant or not possible due to the nature of the product.
Vapor Pressure
Testing not relevant or not possible due to the nature of the product.
Vapor Density
---
Properties Status
---
Solubility
Completely soluble
Odor
Characteristic
Molecular Weight
---
Evaporation Rate
---
Solidification Point
---
Colour
Pale yellow
Physical State Data
liquid
Flammability
Testing not relevant or not possible due to the nature of the product.
Physical State
Liquid
Kinematic Viscosity
---
Form
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable under the conditions, noted in section 7 "Handling and storage".

Reactivity

No data available.

Hazardous reactions

None known.

Avoid

None known.

Incompatible

Strong acids, strong bases, strong oxidizing agents, and strong reducing agents.

Decomposition

The product is not degraded when used as specified in section 1.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Product is not covered by regulations on dangerous waste.

Waste Codes

16 03 05* Organic wastes containing dangerous substances EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Fomtec AFFF 6%?

The signal word is no signal word.

What is the physical form of Fomtec AFFF 6%?

Fomtec AFFF 6% is a liquid with pale yellow color. It has characteristic odor.

What is the solubility of Fomtec AFFF 6%?

Completely soluble

What is Fomtec AFFF 6% used for?

Appliance protection

What is the melting point of Fomtec AFFF 6%?

The melting point is ~ -1 °C and the boiling point is Testing not relevant or not possible due to the nature of the product..