NextSDS Logo
UF

UF-Fluorocell SF

WARNING liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
UF-Fluorocell SF

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
For in-vitro diagnosis
Uses Advised Against
No data available.

Overview

UF-Fluorocell SF is a liquid, viscous substance commonly used for in-vitro diagnosis.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Acute Tox. Category 4 H302

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H302: Harmful if swallowed.

Precautionary Statements

  • P301+P312: IF SWALLOWED: Call a POISON CENTER/doctor if you feel unwell.
  • P501: Dispose of contents/container to a facility in accordance with local and national regulations.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

SYSMEX LTD

undefined

๐Ÿ“

Sysmex House Garamonde Drive Wymbush Milton Keynes Buckinghamshire MK8 8DF United Kingdom

๐ŸŒ

GB

๐Ÿ“ž

+44 (0)333 320 3460

๐Ÿ“ 

+44 (0)1908 267 901

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Giftinformationszentrum Nord

๐Ÿ“ž

+49 (0)551 192 40

๐ŸŒ

DE

๐Ÿ—ฃ๏ธ

Languages: DE, EN

๐Ÿ’ก

For medical advice

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
thylne glycol
EC: 203-473-3
107-21-1 100% โš ๏ธ Hazardous

Composition Notes

Full Text for all H-phrases and EUH-phrases: pls. see section 16 (*,**,***,****) Detailed explanation pls. refer to CLP regulation No. 1272/2008, annex VI, 1.2

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove affected person from the immediate area. Ensure supply of fresh air.

๐Ÿ–๏ธ Skin Contact

Wash off immediately with soap and water.

๐Ÿ‘๏ธ Eye Contact

Separate eyelids, wash the eyes thoroughly with water (15 min.).

๐Ÿฝ๏ธ Ingestion/Swallowing

Call a doctor immediately. Do not induce vomiting. Never give anything by mouth to an unconscious person.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
liquid, viscous
๐ŸŽจ Colour
yellow
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
liquid, viscous
๐Ÿ‘ƒ Odor
odourless
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
No data available
๐ŸงŠ Melting Point
-13 C
Critical Property
๐Ÿ’จ Boiling Point
198 C
Critical Property
๐Ÿ”ฅ Flash Point
398 C
Critical Property
๐Ÿ“Š Freezing Point
-13 C
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
No data available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
No data available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1.11 g/cm
Critical Property
๐Ÿ”ฅ Flammability
No data available
๐Ÿ“Š Upper Explosive Limit
No data available
๐Ÿ“Š Lower Explosive Limit
No data available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
111 C
๐Ÿ“Š Decomposition Temperature
No data available
๐Ÿ’ง Solubility
No data available
๐Ÿ“Š Partition Coefficient
No data available
๐Ÿ“Š Solubility In Water
miscible
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
No data available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

Sufficient protection is given wearing suitable protective gloves checked according to i.e. EN 374, in the event of risk of skin contact with the product. Before use, the protective gloves should be tested in any case for its specific workstation suitability (i.e. mechanical resistance, product compatibility and antistatic properties). Adhere to the manufacturers instructions and information relating to the use, storage, care and replacement of protective gloves. Protective gloves shall be replaced immediately when physically damaged or worn. Design operations thus to avoid permanent use of protective gloves.

๐Ÿ‘๏ธ Eye Protection

Safety glasses with side protection shield (EN 166)

๐Ÿ˜ท Respiratory Protection

If workplace exposure limits are exceeded, a respiration protection approved for this particular job must be worn. In case of aerosol and mist formation, take appropriate measures for breathing protection in the event workplace threshold values are not specified.

๐Ÿฆบ Skin/Body Protection

Normal chemical work clothing.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for UF-Fluorocell SF?

The signal word for this substance is "warning".

What is the physical form of UF-Fluorocell SF?

UF-Fluorocell SF is a liquid appearing as liquid, viscous with yellow color. It has odourless odor.

What is the solubility of UF-Fluorocell SF?

No data available

What is UF-Fluorocell SF used for?

For in-vitro diagnosis

What are the hazard statements for UF-Fluorocell SF?

This substance has 1 hazard statements: H302: Harmful if swallowed.

What is the melting point of UF-Fluorocell SF?

The melting point is -13 C and the boiling point is 198 C.