Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Fluorocell RET
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
For in-vitro diagnosis
Uses advised against
No data available.
Manufacturers & Suppliers
SYSMEX LTD
national supplier
Sysmex House, Garamonde Drive, Wymbush, Milton Keynes, Buckinghamshire, United Kingdom, MK8 8DF
+44 (0)333 320 3460
Emergency Contacts
National Poisons Information Centre
+353 1 809 2166
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| ethanediol EC: 203-473-3 | 107-21-1 | 100% | Yes |
| methanol EC: 200-659-6 | 67-56-1 | 5 - 10% | Yes |
Notes
Full text of H- and EUH-phrases, if not already mentioned in section 2.2: see section 16. (*,**,***,****) Detailed explanation pls. refer to CLP regulation No. 1272/2008, annex VI, 1.2
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove affected person from the immediate area. Ensure supply of fresh air.
Wash off immediately with soap and water.
Separate eyelids, wash the eyes thoroughly with water (15 min.).
Call a doctor immediately. Do not induce vomiting. Never give anything by mouth to an unconscious person.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam; Extinguishing powder; Carbon dioxide; Water spray jet
High power water jet
In the event of fire, the following can be released: Carbon dioxide (CO2); Carbon monoxide (CO); halogenated compounds; Nitrogen oxides (NOx); Boron oxides
Firefighter Protection
Use self-contained breathing apparatus. Wear protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Refer to protective measures listed in sections 7 and 8. Ensure adequate ventilation. Avoid contact with skin, eyes and clothing. Do not inhale vapours. Keep away from ignition sources.
Do not discharge into the drains/surface waters/groundwater. Do not discharge into the subsoil/soil.
Take up with absorbent material (e.g., sand, kieselguhr, universal binder).
Materials: sand, kieselguhr, universal binder
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Risks inherent to handling the product must be minimised by applying the appropriate protective and preventive measures. Working processes should - so far as possible, according to the state of the art - be designed to rule out bodily contact or the release of hazardous substances.
Keep container tightly closed in a cool, well-ventilated place. Containers which are opened must be carefully closed and kept upright to prevent leakage.
Do not eat, drink or smoke during work time. Keep away from food, drink and animal feeding stuffs. Wash hands and skin before breaks and after work. Do not inhale vapours. Avoid contact with eyes and skin. Remove soiled or soaked clothing immediately. Have emergency shower available.
Keep away from sources of heat and ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No data available.
Sufficient protection is given wearing suitable protective gloves checked according to i.e. EN 374, in the event of risk of skin contact with the product. Before use, the protective gloves should be tested in any case for its specific work-station suitability (i.e. mechanical resistance, product compatibility and antistatic properties). Adhere to the manufacturer's instructions and information relating to the use, storage, care and replacement of protective gloves. Protective gloves shall be replaced immediately when physically damaged or worn. Design operations thus to avoid permanent use of protective gloves.
Safety glasses with side protection shield (EN 166)
If workplace exposure limits are exceeded, a respiration protection approved for this particular job must be worn. In case of aerosol and mist formation, take appropriate measures for breathing protection in the event workplace threshold values are not specified.
Normal chemical work clothing.
No data available.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage and handling conditions (See section 7).
Dangerous reactions are not expected if the product is handled according to its intended use.
None, when used as directed.
None, if handled according to intended use.
Aluminium; Chromyl chloride; alkaline hydroxides; Perchloric acid; Oxidizing agents
Formaldehyde
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Allocation of a waste code number, according to the European Waste Catalogue, should be carried out in agreement with the regional waste disposal company.
Allocation of a waste code number, according to the European Waste Catalogue, should be carried out in agreement with the regional waste disposal company.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1993
- Shipping Name
- FLAMMABLE LIQUID, N.O.S.
- Transport Class
- 3
- Packing Group
- III
No data available.
No data available.
No data available.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Fluorocell RET?
The signal word is warning.
What is the physical form of Fluorocell RET?
Fluorocell RET is a liquid with blue color. It has odourless odor.
What is the solubility of Fluorocell RET?
No data available
What is Fluorocell RET used for?
For in-vitro diagnosis
What are the hazard statements for Fluorocell RET?
This substance has 3 hazard statements:
- H226: Flammable liquid and vapour.
- H302: Harmful if swallowed.
- H371: May cause damage to organs.
What is the melting point of Fluorocell RET?