Product Information

Product Name
PK & G6PDH Digitonin Hemolyzing Reagent
Product Code
3028

Regulatory Identifiers

CAS Number
N/A

Identified Uses

In vitro diagnostic

Uses advised against

All uses not specified in this section or in section 7.3

Manufacturers & Suppliers

INstruchemie BV logo

INstruchemie BV

manufacturer

Zwet 26, 9932 AB Delfzijl - The Netherlands

+31 (0)596 634 831

www.instruchemie.nl

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

None of the substances contained in the mixture are above the limits specified in Annex II of Regulation (EC) No 1907/2006

Notes

Chemical description: Not defined

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of symptoms, move the person affected into fresh air.

Skin contact

In case of contact it is recommended to clean the affected area thoroughly with water and neutral soap. In case of changes to the skin (stinging, redness, rashes, blisters,...), seek medical advice with this Safety Data Sheet

Symptoms: stinging, redness, rashes, blisters

Eye contact

Rinse with water until the product has been eliminated. In case of problems, consult a doctor showing the SDS for the product.

Ingestion

In case of consumption in large quantities, it is recommended to seek medical assistance.

Immediate Medical Attention

In case of consumption in large quantities, it is recommended to seek medical assistance.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Product is non-flammable under normal conditions of storage, handling and use. In the case of combustion as a result of improper handling, storage or use preferably use polyvalent powder extinguishers (ABC powder), in accordance with the Regulation on fire protection systems.

Unsuitable media

Non-applicable

Specific hazards

Due to its non-inflammable nature, the product does not present a fire risk under normal conditions of storage, handling and use.

Instructions

In case of fire, cool the storage containers and tanks for products susceptible to combustion, explosion or BLEVE as a result of high temperatures. Eliminate all sources of ignition.

Firefighter Protection

Depending on the magnitude of the fire it may be necessary to use full protective clothing and Self Contained Breathing Apparatus. Minimum emergency facilities and equipment should be available (fire blankets, portable first aid kit,...)

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Isolate leaks provided that there is no additional risk for the people performing this task.

Small spill

Contain spillage using barriers or similar equipment. Use suitable absorbents for collection and treat the waste in accordance with current regulations.

Large spill

If possible, contain spillage in open water using barriers or similar equipment. If this is not possible, try to control its spread and collect the product with suitable mechanical means. Always consult experts before using dispersants and make sure you have the necessary approvals if they are to be used. Treat the waste according to current regulations.

Environmental

Keep product away from drains, surface and ground water.

Cleanup methods

Absorb the spill using sand or inert absorbent and move it to a safe place. Do not absorb in sawdust or other combustible absorbents. Collect the product in appropriate containers and manage it according to current legislation.

Materials: sand or inert absorbent

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Comply with the current legislation concerning the prevention of industrial risks with regards manually handling weights. Maintain order, cleanliness and dispose of using safe methods.

Storage

Store in a cool, dry, well-ventilated location. Avoid sources of heat, radiation, static electricity and contact with food.

Hygiene

Do not eat or drink during the process, washing hands afterwards with suitable cleaning products.

Fire prevention

It is recommended to transfer at a slow speed to avoid the creation of electrostatic charges. Avoid sources of heat, radiation, static electricity.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Protective gloves against minor risks. Replace gloves in case of any sign of damage. For prolonged periods of exposure to the product for professional users/industrials, we recommend using CE III gloves in line with standards EN ISO 21420:2020 and EN ISO 374-1:2016+A1:2018.

Eyes

Panoramic glasses against splash/projections. EN 166:2002, EN ISO 4007:2018. Clean daily and disinfect periodically according to the manufacturer’s instructions. Use if there is a risk of splashing.

Respiratory

If the working conditions and/or safety measures adopted do not allow keeping the airborne concentration of the product below the exposure limits (if any) or at acceptable levels (if no exposure limits exist), suitable respiratory protection equipment chosen by a qualified professional should be used.

Skin/Body

Work clothing: Replace before any evidence of deterioration. For periods of prolonged exposure to the product for professional/industrial users CE III is recommended, in accordance with the regulations in EN ISO 6529:2013, EN ISO 6530:2005, EN ISO 13688:2013, EN 464:1994. Anti-slip work shoes: Replace before any evidence of deterioration. For periods of prolonged exposure to the product for professional/industrial users CE III is recommended, in accordance with the regulations in EN ISO 20345:2022 y EN 13832-1:2019.

Environmental

To comply with environmental protection regulations, it is recommended to prevent any spillage of the product and its container.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Relative Density
1,031
Relative Evaporation Rate
---
Metal Corrosion
Not relevant *
Solubility In Fat
---
Partition Coefficient
Not relevant *
Ph
Not relevant *
Molecular Weight
---
Crystallisation Point
---
Properties Status
---
Lower Explosive Limit
Not relevant *
Upper Explosive Limit
Not relevant *
Vapor Pressure
2350 Pa
Bulk Density
---
Flammability
Not relevant *
Explosive Limits
---
Appearance
Not relevant *
Colour Intensity
---
Solidification Point
---
Solubility
Not relevant *
Evaporation Rate
Not relevant *
Dynamic Viscosity
Not relevant *
Auto Ignition Temperature
Not relevant *
Voc Content
---
Vapor Density
Not relevant *
Solubility In Water
Not relevant *
Cloud Point
---
Odor Threshold
Not relevant *
Melting Point
Not relevant *
Decomposition Temperature
Not relevant *
Odor
Not relevant *
Flash Point
Non Flammable (>60 °C)
Physical State
Liquid
Colour
Not relevant *
Boiling Point
100 °C
Kinematic Viscosity
Not relevant *
Density
1030,9 kg/m³
Freezing Point
Not relevant *
Form
---
Physical State Data
liquid
Softening Point
---
State Under Standard Conditions
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Chemically stable under the indicated conditions of storage, handling and use.

Reactivity

No hazardous reactions are expected because the product is stable under recommended storage conditions.

Hazardous reactions

Under the specified conditions, hazardous reactions that lead to excessive temperatures or pressure are not expected.

Avoid

Shock and friction: Not applicable, Contact with air: Not applicable, Increase in temperature: Not applicable, Sunlight: Not applicable, Humidity: Not applicable

Incompatible

Acids: Avoid strong acids, Water: Not applicable, Oxidising materials: Not applicable, Combustible materials: Not applicable, Others: Avoid alkalis or strong bases

Decomposition

Depending on the decomposition conditions, complex mixtures of chemical substances can be released: carbon dioxide (CO₂), carbon monoxide and other organic compounds.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Consult the authorized waste service manager on the assessment and disposal operations in accordance with Annex 1 and Annex 2 (Directive 2008/98/EC).

Disposal

Consult the authorized waste service manager on the assessment and disposal operations in accordance with Annex 1 and Annex 2 (Directive 2008/98/EC).

Waste Codes

16 05 09 discarded chemicals other than those mentioned in 16 05 06, 16 05 07 or 16 05 08 EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

This SDS is an English translation of COMMISSION REGULATION (EU) 2020/878, without any country-specific legislation

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for PK & G6PDH Digitonin Hemolyzing Reagent?

The signal word is no signal word.

What is the physical form of PK & G6PDH Digitonin Hemolyzing Reagent?

PK & G6PDH Digitonin Hemolyzing Reagent is a liquid appearing as not relevant * with not relevant * color. It has not relevant * odor.

What is the solubility of PK & G6PDH Digitonin Hemolyzing Reagent?

Not relevant *

What is PK & G6PDH Digitonin Hemolyzing Reagent used for?

In vitro diagnostic

What is the melting point of PK & G6PDH Digitonin Hemolyzing Reagent?

The melting point is Not relevant * and the boiling point is 100 °C.