Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Calibration gas, Test gas, H2S, NO2, CO, CO2, NH3, H2, SO2, CH4, C2H4, C3H8, C4H10, C4H8, C5H12, C6H14, C7H8, SF6, O2, N2-Bal [configured]
- Product Form
- Gas mixture
- Product Code
- various calibration gases in air (about 18% O2, N2- - various, see Section 16
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Gas mixture for the calibration of sensors.
Uses advised against
Do not use for inflating balloons. Do not use for medical-clinical purposes. Do not use for private purposes (household).
Manufacturers & Suppliers
Dräger Safety UK Ltd.
Ullswater Close, Blyth Riverside Business Park UK-NE24 4RG Blyth; Northumberland
+44 1670 352891
www.draeger.com
Dräger Global EHS Management
+49 451 882 5997
Emergency Contacts
National Poisons Information Service, West Midlands Poisons Unit
(0) 12 15 07 55 88/9
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS04
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Included depending on the version:
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Nitrogen EC: 231-783-9 | 7727-37-9 | 74% | No |
| Carbon dioxide EC: 204-696-9 | 124-38-9 | 20% | No |
| oxygen EC: 231-956-9 | 7782-44-7 | 18% | Yes |
| propane EC: 200-827-9 | 74-98-6 | 5% | Yes |
| methane EC: 200-812-7 | 74-82-8 | 3% | Yes |
| hydrogen EC: 215-605-7 | 1333-74-0 | 2.2% | Yes |
| ethylene EC: 200-815-3 | 74-85-1 | 1.5% | Yes |
| butane EC: 203-448-7 | 106-97-8 | 1% | Yes |
| n-hexane EC: 203-777-6 | 110-54-3 | 0.8% | Yes |
| pentane EC: 203-692-4 | 109-66-0 | 0.5% | Yes |
| but-1-ene EC: 203-449-2 | 106-98-9 | 0.3% | Yes |
| carbon monoxide EC: 211-128-3 | 630-08-0 | 0.3% | Yes |
| Sulphur hexafluoride EC: 219-854-2 | 2551-62-4 | 0.2% | Yes |
| toluene EC: 203-625-9 | 108-88-3 | 0.1% | Yes |
| sulphur dioxide EC: 231-195-2 | 7446-09-5 | 0.1% | Yes |
| ammonia, anhydrous EC: 231-635-3 | 7664-41-7 | 0.05% | Yes |
| nitrogen dioxide EC: 233-272-6 | 10102-44-0 | 0.05% | Yes |
| 2-methylpropene EC: 204-066-3 | 115-11-7 | 0.015% | Yes |
| hydrogen sulphide EC: 231-977-3 | 7783-06-4 | 0.01% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove casualty to fresh air and keep warm and at rest. Provide fresh air.
No special measures are necessary.
Medical Treatment
Treat symptomatically. Where appropriate artificial ventilation.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
ABC-powder Carbon dioxide (CO2) Water spray jet
Co-ordinate fire-fighting measures to the fire surroundings. Use water spray jet to cool endangered containers.
Firefighter Protection
In case of fire: Wear self-contained breathing apparatus. Use water spray jet to protect personnel.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
For non-emergency personnel: Provide adequate ventilation. Remove all sources of ignition. Be aware that gases can spread at ground level (heavier than air) and pay attention to the wind direction. For emergency responders: Ensure adequate ventilation.
Suppress gases/vapours/mists with water spray jet.
Related Products
Similar products with comparable safety profiles
Calibration gas, Test gas, Kalibriergas H2S, CO, CO2, CH4, C3H8, C5H12, EtOH, N2-Bal [configured]
---
Calibrataion gas; Testgas N2 >99.99%
---
Precision Calibration Gas Mixture
---
5% CO2 IN AIR, HIGH LEVEL CALIBRANT GAS
CAS: 124-38-9
5% CO2 IN AIR, BASELINE CALIBRANT GAS
CAS: 124-38-9
NON-FLAMMABLE GAS MIXTURE Containing One or More of the Following Components in a Nitrogen Balance Gas: Carbon Monoxide, 0.0005 1.0%; Hydrogen, 0 2.0%; Methane, 0 2.5%; Oxygen, 0 23.5%
---
Compressed Gas, containing <= 21 Vol.-% Oxygen, Carbon dioxide, balance Nitrogen
---
SA4001-2 SA4001-001 H2S Replacement Reference Gas
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
If local exhaust ventilation is not possible or not sufficient, the entire working area should be ventilated by technical means. No special measures are necessary. Handle and open container with care. Use only in well-ventilated areas. Keep away from sources of ignition - No smoking. The product is not: Combustible. The product is: oxidising. Usual measures for fire prevention. Avoid effect of heat. Do not inhale gases.
Keep/Store only in original container. Keep container tightly closed. Ensure adequate ventilation of the storage area. Do not store with chemicals. Keep only in the original container in a cool, well-ventilated place. Keep container tightly closed in a cool, well-ventilated place. Handle and open container with care. Protect pressurised gas bottles against overturning. Storage temperature may not exceed 50°C (=122°F).
When using do not eat, drink, smoke, sniff. Work in rooms with good ventilation. Wash hands before breaks and after work.
Keep away from sources of ignition - No smoking. Usual measures for fire prevention. Avoid effect of heat.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Technical measures to prevent exposure not determined
Protective gloves against mechanical risks. Chemical hazards can not be expected under normal use.
Eye glasses with side protection
Respiratory protection necessary at: - insufficient exhaust - prolonged exposure - Suitable respiratory protection apparatus: - Multi-purpose filter ABEK
Light protective clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
not determined
No hazardous reactions known.
not determined
Danger of bursting container.
No data available
Gas mixture may contain toxic gases in low concentrations, which could be released. Decomposition products of the respective test gas components.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of waste according to applicable legislation. Completely emptied packages can be recycled.
Dispose of waste according to applicable legislation.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN 1956
- Shipping Name
- COMPRESSED GAS, N.O.S.
- Transport Class
- 2.2
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Calibration gas, Test gas, H2S, NO2, CO, CO2, NH3, H2, SO2, CH4, C2H4, C3H8, C4H10, C4H8, C5H12, C6H14, C7H8, SF6, O2, N2-Bal [configured]?
The signal word is warning.
What is the physical form of Calibration gas, Test gas, H2S, NO2, CO, CO2, NH3, H2, SO2, CH4, C2H4, C3H8, C4H10, C4H8, C5H12, C6H14, C7H8, SF6, O2, N2-Bal [configured]?
Calibration gas, Test gas, H2S, NO2, CO, CO2, NH3, H2, SO2, CH4, C2H4, C3H8, C4H10, C4H8, C5H12, C6H14, C7H8, SF6, O2, N2-Bal [configured] is a compressed gas with colourless color.
What is the solubility of Calibration gas, Test gas, H2S, NO2, CO, CO2, NH3, H2, SO2, CH4, C2H4, C3H8, C4H10, C4H8, C5H12, C6H14, C7H8, SF6, O2, N2-Bal [configured]?
not determined
What is Calibration gas, Test gas, H2S, NO2, CO, CO2, NH3, H2, SO2, CH4, C2H4, C3H8, C4H10, C4H8, C5H12, C6H14, C7H8, SF6, O2, N2-Bal [configured] used for?
Gas mixture for the calibration of sensors.
What are the hazard statements for Calibration gas, Test gas, H2S, NO2, CO, CO2, NH3, H2, SO2, CH4, C2H4, C3H8, C4H10, C4H8, C5H12, C6H14, C7H8, SF6, O2, N2-Bal [configured]?
This substance has 1 hazard statement:
- H280: Contains gas under pressure; may explode if heated.
What is the melting point of Calibration gas, Test gas, H2S, NO2, CO, CO2, NH3, H2, SO2, CH4, C2H4, C3H8, C4H10, C4H8, C5H12, C6H14, C7H8, SF6, O2, N2-Bal [configured]?
The melting point is not determined and the boiling point is approx. -195 °C.