Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Calibration gas, Test gas, Kalibriergas H2S, CO, CO2, CH4, C3H8, C5H12, EtOH, N2-Bal [configured]
- Product Form
- Gas mixture
- Product Code
- various calibration gases in nitrogen
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Gas mixture for the calibration of sensors
Uses advised against
Do not use for inflating balloons. Do not use for medical-clinical purposes. Do not use for private purposes (household).
Manufacturers & Suppliers
Dräger Safety AG & Co. KGaA
distributor
Revalstr. 1, D-23560 Lübeck
+49 (0) 451/882-0
www.draeger.com
Dräger Safety AG & Co. KGaA
manufacturer
Revalstr. 1, D-23560 Lübeck
+49 (0) 451/882-0
www:draeger.com
Emergency Contacts
Giftinformationszentrum Nord, Göttingen
(0551) 1 92 40
Dräger Werkschutz
+49 (0) 451/ 882-2395
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS04
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| ethanol EC: 200-578-6 | 64-17-5 | 0.01% | Yes |
| methane EC: 200-812-7 | 74-82-8 | 3% | Yes |
| propane EC: 200-827-9 | 74-98-6 | 5% | Yes |
| pentane EC: 203-692-4 | 109-66-0 | 1% | Yes |
| carbon-monoxide EC: 211-128-3 | 630-08-0 | 0.01% | Yes |
| Hydrogen sulphide EC: 231-977-3 | 7783-06-4 | 0.01% | Yes |
| carbon dioxide EC: 204-696-9 | 124-38-9 | 3% | No |
| Nitrogen EC: 231-783-9 | 7727-37-9 | 92% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove the casualty into fresh air and keep him immobile. Ensure of fresh air.
No special measure necessary.
Medical Treatment
Treat symptoms. If necessary, give oxygen.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Fire-extinguishing activities according to surrounding. ABC powder Carbon dioxide Water spray jet
no
No information available.
Fire-extinguishing activities according to surrounding.
Firefighter Protection
Use breathing apparatus with independent air supply.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
For non-emergency personnel: Ensure adequate ventilation. Keep away sources of ignition. Pay attention to extension of gas especially at ground (heavier than air) and in direction of the wind. For emergency responders: Ensure adequate ventilation.
Suppress gases/vapours/mists with water spray jet. Keep at a distance of water.
Suck off by room ventilation. take up dry
Related Substances
Similar chemicals with comparable safety profiles
Calibration gas, Test gas, H2S, NO2, CO, CO2, NH3, H2, SO2, CH4, [configured] C2H4, C3H8, C4H10, C4H8, C5H12, C6H14, C7H8, SF6, O2, N2-Bal
---
Calibrataion gas; Testgas N2 >99.99%
---
5% CO2 IN AIR, HIGH LEVEL CALIBRANT GAS
CAS: 124-38-9
5% CO2 IN AIR, BASELINE CALIBRANT GAS
CAS: 124-38-9
Precision Calibration Gas Mixture
---
CALIBRATION MIXTURE FOR RADIOMETER BASEL AG CAL-GAS REF 064 0210
---
Compressed Gas, containing <= 21 Vol.-% Oxygen, Carbon dioxide, balance Nitrogen
---
SA4001-2 SA4001-001 H2S Replacement Reference Gas
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Care for thoroughly room ventilation, if necessary use in well ventilated area with local exhaust ventilation at workplace. No special measures necessary if used correctly. Open and handle container with care! Use only in well-ventilated areas. Do not inhale gases.
Keep in closed original container. Ventilate store-rooms thoroughly. Keep container tightly closed, store at cool and aired place, open and handle carefully. Protect compressed gas-bottles from falling down. Storage temperature may not exceed 50°C (=122°F).
At work do not eat, drink and smoke. Work in rooms with good ventilation. Wash hands before breaks and after work.
Keep away from sources of ignition - No smoking. The product is not combustible, but supports burning. Pay attention to general rules of internal fire prevention. Avoid effect of heat.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Appropriate engineering controls not determined
Protective gloves
safety goggles with side protection
In case of insufficient ventilation or long-term effect use breathing apparatus.
Light protective clothing.
Limitation and surveillance of the environment Observe the expiry date.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
not determined
No hazardous reactions known.
not determined
Danger of bursting container.
No data available
Hydrocarbons, gaseous Hydrogen sulphide (H $ _{2} $ S) Carbon monoxide and carbon dioxide. Toxic gases/vapours
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1956
- Shipping Name
- Compressed gas, n.o.s. (Nitrogen, ...........)
- Transport Class
- 2.2
- Packing Group
- ./.
no
no
no
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Calibration gas, Test gas, Kalibriergas H2S, CO, CO2, CH4, C3H8, C5H12, EtOH, N2-Bal [configured]?
The signal word is warning.
What is the physical form of Calibration gas, Test gas, Kalibriergas H2S, CO, CO2, CH4, C3H8, C5H12, EtOH, N2-Bal [configured]?
Calibration gas, Test gas, Kalibriergas H2S, CO, CO2, CH4, C3H8, C5H12, EtOH, N2-Bal [configured] is a compressed gas appearing as compressed gas with colourless color. It has of rotten eggs odor.
What is the solubility of Calibration gas, Test gas, Kalibriergas H2S, CO, CO2, CH4, C3H8, C5H12, EtOH, N2-Bal [configured]?
not determined
What is Calibration gas, Test gas, Kalibriergas H2S, CO, CO2, CH4, C3H8, C5H12, EtOH, N2-Bal [configured] used for?
Gas mixture for the calibration of sensors
What are the hazard statements for Calibration gas, Test gas, Kalibriergas H2S, CO, CO2, CH4, C3H8, C5H12, EtOH, N2-Bal [configured]?
This substance has 1 hazard statement:
- H280: Contains gas under pressure; may explode if heated.
What is the melting point of Calibration gas, Test gas, Kalibriergas H2S, CO, CO2, CH4, C3H8, C5H12, EtOH, N2-Bal [configured]?
The melting point is No data available and the boiling point is ca. -195 °C.