Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Calibration gas, Test gas, Kalibriergas H2S, CO, CO2, CH4, C3H8, C5H12, EtOH, N2-Bal [configured]
Product Form
Gas mixture
Product Code
various calibration gases in nitrogen

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Gas mixture for the calibration of sensors

Uses advised against

Do not use for inflating balloons. Do not use for medical-clinical purposes. Do not use for private purposes (household).

Manufacturers & Suppliers

Dräger Safety AG & Co. KGaA logo

Dräger Safety AG & Co. KGaA

distributor

Revalstr. 1, D-23560 Lübeck

+49 (0) 451/882-0

www.draeger.com

Dräger Safety AG & Co. KGaA logo

Dräger Safety AG & Co. KGaA

manufacturer

Revalstr. 1, D-23560 Lübeck

+49 (0) 451/882-0

www:draeger.com

Emergency Contacts

Giftinformationszentrum Nord, Göttingen

(0551) 1 92 40

Dräger Werkschutz

+49 (0) 451/ 882-2395

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Press. Gas (Comp.) H280

GHS Pictograms

GHS04 - Compressed gas

GHS04

Hazard Statements

H280 Contains gas under pressure; may explode if heated.

Precautionary Statements

P103 Read label before use.
P202 Do not handle until all safety precautions have been read and understood.
P233 Keep container tightly closed.
P376 Stop leak if safe to do so.
P403 + P233 Store in a well-ventilated place. Keep container tightly closed.
P410 + P403 Protect from sunlight. Store in a well-ventilated place.
P412 Do not expose to temperatures exceeding 50°C/ 122°F.
P501 Contents / container to properly dispose and recycle.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
ethanol EC: 200-578-6 64-17-5 0.01% Yes
methane EC: 200-812-7 74-82-8 3% Yes
propane EC: 200-827-9 74-98-6 5% Yes
pentane EC: 203-692-4 109-66-0 1% Yes
carbon-monoxide EC: 211-128-3 630-08-0 0.01% Yes
Hydrogen sulphide EC: 231-977-3 7783-06-4 0.01% Yes
carbon dioxide EC: 204-696-9 124-38-9 3% No
Nitrogen EC: 231-783-9 7727-37-9 92% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove the casualty into fresh air and keep him immobile. Ensure of fresh air.

Skin contact

No special measure necessary.

Medical Treatment

Treat symptoms. If necessary, give oxygen.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Fire-extinguishing activities according to surrounding. ABC powder Carbon dioxide Water spray jet

Unsuitable media

no

Specific hazards

No information available.

Instructions

Fire-extinguishing activities according to surrounding.

Firefighter Protection

Use breathing apparatus with independent air supply.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

For non-emergency personnel: Ensure adequate ventilation. Keep away sources of ignition. Pay attention to extension of gas especially at ground (heavier than air) and in direction of the wind. For emergency responders: Ensure adequate ventilation.

Environmental

Suppress gases/vapours/mists with water spray jet. Keep at a distance of water.

Cleanup methods

Suck off by room ventilation. take up dry

Related Substances

Similar chemicals with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Care for thoroughly room ventilation, if necessary use in well ventilated area with local exhaust ventilation at workplace. No special measures necessary if used correctly. Open and handle container with care! Use only in well-ventilated areas. Do not inhale gases.

Storage

Keep in closed original container. Ventilate store-rooms thoroughly. Keep container tightly closed, store at cool and aired place, open and handle carefully. Protect compressed gas-bottles from falling down. Storage temperature may not exceed 50°C (=122°F).

Hygiene

At work do not eat, drink and smoke. Work in rooms with good ventilation. Wash hands before breaks and after work.

Fire prevention

Keep away from sources of ignition - No smoking. The product is not combustible, but supports burning. Pay attention to general rules of internal fire prevention. Avoid effect of heat.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Appropriate engineering controls not determined

Hands

Protective gloves

Eyes

safety goggles with side protection

Respiratory

In case of insufficient ventilation or long-term effect use breathing apparatus.

Skin/Body

Light protective clothing.

Environmental

Limitation and surveillance of the environment Observe the expiry date.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Crystallisation Point
---
Freezing Point
---
Relative Density
ca. 1 g/cm³
Density
---
Kinematic Viscosity
not determined
Solubility In Water
No data available
Softening Point
---
Melting Point
No data available
Boiling Point
ca. -195 °C
Bulk Density
not applicable
Form
---
Relative Evaporation Rate
---
Molecular Weight
---
Vapor Density
ca. 1
State Under Standard Conditions
---
Colour
colourless
Physical State Data
gas
Solidification Point
---
Odor Threshold
No data available
Metal Corrosion
---
Solubility In Fat
---
Dynamic Viscosity
not determined
Partition Coefficient
not determined
Evaporation Rate
not determined
Properties Status
---
Flash Point
not applicable
Solubility
not determined
Auto Ignition Temperature
not applicable
Voc Content
---
Flammability
not determined
Explosive Limits
---
Colour Intensity
---
Vapor Pressure
not applicable
Decomposition Temperature
No data available
Physical State
compressed gas
Lower Explosive Limit
No information available.
Cloud Point
---
Upper Explosive Limit
No information available.
Appearance
compressed gas
Ph
not applicable
Odor
of rotten eggs
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

not determined

Reactivity

No hazardous reactions known.

Hazardous reactions

not determined

Avoid

Danger of bursting container.

Incompatible

No data available

Decomposition

Hydrocarbons, gaseous Hydrogen sulphide (H $ _{2} $ S) Carbon monoxide and carbon dioxide. Toxic gases/vapours

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1956
Shipping Name
Compressed gas, n.o.s. (Nitrogen, ...........)
Transport Class
2.2
Packing Group
./.
ADR

no

IMDG

no

IATA

no

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Calibration gas, Test gas, Kalibriergas H2S, CO, CO2, CH4, C3H8, C5H12, EtOH, N2-Bal [configured]?

The signal word is warning.

What is the physical form of Calibration gas, Test gas, Kalibriergas H2S, CO, CO2, CH4, C3H8, C5H12, EtOH, N2-Bal [configured]?

Calibration gas, Test gas, Kalibriergas H2S, CO, CO2, CH4, C3H8, C5H12, EtOH, N2-Bal [configured] is a compressed gas appearing as compressed gas with colourless color. It has of rotten eggs odor.

What is the solubility of Calibration gas, Test gas, Kalibriergas H2S, CO, CO2, CH4, C3H8, C5H12, EtOH, N2-Bal [configured]?

not determined

What is Calibration gas, Test gas, Kalibriergas H2S, CO, CO2, CH4, C3H8, C5H12, EtOH, N2-Bal [configured] used for?

Gas mixture for the calibration of sensors

What are the hazard statements for Calibration gas, Test gas, Kalibriergas H2S, CO, CO2, CH4, C3H8, C5H12, EtOH, N2-Bal [configured]?

This substance has 1 hazard statement:

  • H280: Contains gas under pressure; may explode if heated.

What is the melting point of Calibration gas, Test gas, Kalibriergas H2S, CO, CO2, CH4, C3H8, C5H12, EtOH, N2-Bal [configured]?

The melting point is No data available and the boiling point is ca. -195 °C.