NextSDS Logo
MR

MR 751 Special Ultrasonic coupling agent

NO SIGNAL WORD gel SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
MR 751 Special Ultrasonic coupling agent
Product Form
strippable, water soluble

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Couple gel for ultrasonic testing, technically

Overview

MR 751 Special Ultrasonic coupling agent commonly used couple gel for ultrasonic testing, technically.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Not Classified

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

MR-Chemie GmbH

manufacturer

๐Ÿ“

Nordstr. 61-63 D-59427 Unna

๐ŸŒ

DE

๐Ÿ“ž

+49 (0)2303/95151-0

๐Ÿ“ 

+49 (0)2303/95151-10

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

1 800 424 9300

๐ŸŒ

US

๐Ÿ•’

Day or Night

๐Ÿ’ก

within USA and Canada

WISAG FMO Cargo Service GmbH & CO.KG

๐Ÿ“ž

001 703 527 3887

๐ŸŒ

US

๐Ÿ•’

Day or Night

๐Ÿ’ก

Outside USA and Canada

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixtures

General Composition

Aquaceous gel with subordinated parts of cellulose ether and surfactants

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
(Ethylendioxy)dimethanol
EC: 222-720-6
3586-55-8 1-5% โš ๏ธ Hazardous

Additional Information

For the wording of the listed risk phrases refer to section 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

No special measures required.

๐Ÿ–๏ธ Skin Contact

Immediately wash with water and soap and rinse thoroughly.

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do not induce vomiting; call for medical help immediately. If symptoms persist consult doctor.

Medical Treatment

Grease with skin-cream to restore fat film in order to prevent skin inflammation.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿ”ฅ Flash Point
Not applicable.
Critical Property
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Physical State Data
Not available
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ“Š Properties Status
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Auto Ignition Temperature
Product is not self-igniting.
๐Ÿ“Š Solubility In Water
Fully miscible.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Odor Threshold
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐Ÿ’จ Vapor Pressure
23 hPa
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Fat
Not available
๐ŸงŠ Melting Point
- 5C
Critical Property
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Freezing Point
Not available
๐Ÿ”ฅ Flammability
Not available
๐Ÿ‘ƒ Odor
Characteristic
๐ŸŽจ Colour
Green
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Form
gel
๐Ÿ“Š Dynamic Viscosity
10000 mPas
๐Ÿ“Š Voc Content
0.0 %
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿงช Physical State
gel
Critical Property
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
โš–๏ธ Density
1 g/cm
Critical Property
๐Ÿ’จ Boiling Point
> 97C
Critical Property
๐Ÿงช Ph
< 9
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Bulk Density
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

For good ventilation provide, this can be achieved by local or space exhaust.

๐Ÿงค Hand Protection

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Rubber gloves, Natural rubber, NR. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

๐Ÿ‘๏ธ Eye Protection

Tightly sealed goggles

๐Ÿ˜ท Respiratory Protection

For good ventilation provide, this can be achieved by local or space exhaust. If the concentration lies over the job limit values, then, a certified respirator suitable for this purpose must be used.

๐Ÿฆบ Skin/Body Protection

Protective work clothing

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

Void

๐Ÿ“ฆ Proper Shipping Name

Void

โš ๏ธ Transport Hazard Class

Void

๐Ÿ“‹ Packing Group

Void

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for MR 751 Special Ultrasonic coupling agent?

The signal word for this substance is "no signal word".

What is the physical form of MR 751 Special Ultrasonic coupling agent?

MR 751 Special Ultrasonic coupling agent is a gel with green color. It has characteristic odor.

What is MR 751 Special Ultrasonic coupling agent used for?

Couple gel for ultrasonic testing, technically

What is the melting point of MR 751 Special Ultrasonic coupling agent?

The melting point is - 5C and the boiling point is > 97C.