Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- MR® 751 Special Ultrasonic coupling agent
- Product Form
- bulk
- Synonyms
- strippable, water soluble
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Couple gel for ultrasonic testing, technically
Manufacturers & Suppliers
MR-Chemie GmbH
manufacturer
Nordstr. 61-63, D-59427 Unna
+49 (0)2303/95151-0
Emergency Contacts
For Chemical Emergency, Spill, Leak, Fire, Exposure or Accident
1 800 424 9300
Day or Night
WISAG FMO Cargo Service GmbH & CO.KG
001 703 527 3887
24h
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Aquaeous gel with subordinated parts of cellulose ether and surfactants
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| (Ethylenedioxy)dimethanol EC: 222-720-6 | 3586-55-8 | 1 - 5% | Yes |
For the wording of the listed risk phrases refer to section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
No special measures required.
Immediately wash with water and soap and rinse thoroughly.
Rinse opened eye for several minutes under running water. Then consult a doctor.
Do not induce vomiting; call for medical help immediately. If symptoms persist consult doctor.
Immediate Medical Attention
Call for medical help immediately if swallowed; consult a doctor if eye contact occurs or symptoms persist.
Medical Treatment
Grease with skin-cream to restore fat film in order to prevent skin inflammation.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water, drying fire extinguishing agent, CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
In case of fire, the following can be released: Carbon monoxide (CO)
Firefighter Protection
Wear self-contained respiratory protective device.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not allow to enter sewers/ surface or ground water.
Absorb with liquid-binding material
Related Products
Similar products with comparable safety profiles
MR® 79 Special Cleaner
---
RS Pro Ultrasonic Cleaning Liquid
UFI: 44R7-J06P-U004-KM5N
MR® 76 FA Magnetic powder suspension (Aerosol)
---
AQUASONIC® 100 ULTRASOUND TRANSMISSION GEL
---
MR® 68 C Penetrant
---
MR® 76 S Magnetic powder suspension, black
---
MR® 76 S Magnetic powder suspension, black, ready for use, Version A Aerosol
---
EPIKURE™ Curing Agent MGS LH 286
UFI: WW85-F7SK-FCCM-QSUC
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
No special measures required.
Store frost-protected. Store in a cool location. Keep receptacles tightly sealed. Protect from heat and direct sunlight.
No special measures required.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
For good ventilation provide, this can be achieved by local or space exhaust.
Rubber gloves, Natural rubber, NR. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.
Tightly sealed goggles
If the concentration lies over the job limit values, then, a certified respirator suitable for this purpose must be used.
Protective work clothing
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No dangerous reactions known.
No further relevant information available.
No further relevant information available.
No dangerous decomposition products known. No decomposition if used according to specifications.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Smaller quantities can be disposed of with household waste.
For this product no waste key number can be specified, because only the intended purpose permits an allocation. The waste key number is to be specified in arrangement with the regional waste disposal.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Void
- Shipping Name
- Void
- Transport Class
- Class Void
- Packing Group
- Void
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is MR® 751 Special Ultrasonic coupling agent known by?
MR® 751 Special Ultrasonic coupling agent is also known as: strippable, water soluble
What is the hazard signal word for MR® 751 Special Ultrasonic coupling agent?
The signal word is no signal word.
What is the physical form of MR® 751 Special Ultrasonic coupling agent?
MR® 751 Special Ultrasonic coupling agent is a gel with green color. It has characteristic odor.
What is MR® 751 Special Ultrasonic coupling agent used for?
Couple gel for ultrasonic testing, technically
What is the melting point of MR® 751 Special Ultrasonic coupling agent?
The melting point is - 5°C and the boiling point is > 97°C.