NextSDS Logo
Safety Data Sheet EN

Murex® 7018 MR®

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Murex® 7018 MR®
Product Form
1/4" (6.4 mm)

Regulatory Identifiers

CAS Number
N/A

Identified Uses

SMAW (Shielded Metal Arc Welding)

Uses advised against

Not known. Read this SDS before using this product.

Manufacturers & Suppliers

The Lincoln Electric Company logo

The Lincoln Electric Company

manufacturer

22801 Saint Clair Avenue, Cleveland, Ohio 44117, USA

+1 (216) 481-8100

https://www.lincolnelectric.com/sds

The Lincoln Electric Company of Canada LP logo

The Lincoln Electric Company of Canada LP

manufacturer

179 Wicksteed Avenue, Toronto, Ontario M4G 2B9, Canada

+1 (416) 421-2600

https://www.lincolnelectric.com/sds

Emergency Contacts

USA/Canada/Mexico

+1 (888) 609-1762

Americas/Europe

+1 (216) 383-8962

Asia Pacific

+1 (216) 383-8966

Middle East/Africa

+1 (216) 383-8969

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Hazard Statements

Not applicable

Precautionary Statements

Not applicable

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Iron 7439-89-6 50 - 100% Yes
Limestone 1317-65-3 5 - 10% Yes
Calcium fluoride 7789-75-5 5 - 10% Yes
Fluorides (as F) 16984-48-8 1 - 5% Yes
Sodium silicate 1344-09-8 1 - 5% Yes
Manganese 7439-96-5 1 - 5% Yes
Silicon 7440-21-3 0.1 - 1% Yes
Titanium dioxide (naturally occurring) 13463-67-7 0.1 - 1% Yes
Titanium dioxide (synthetic) 13463-67-7 0.1 - 1% Yes
Potassium silicate 1312-76-1 0.1 - 1% Yes
Carboxymethyl cellulose, sodium salt 9004-32-4 0.1 - 1% Yes
Magnesite 546-93-0 0.1 - 1% Yes
Silicon dioxide (amorphous) 7631-86-9 0.1 - 1% Yes
Bentonite 1302-78-9 0.1 - 1% Yes
Quartz 14808-60-7 0.1 - 1% Yes
Potassium oxide 12136-45-7 0.1 - 1% Yes
Hydroxyethyl cellulose 9004-62-0 0.1 - 1% Yes

* All concentrations are percent by weight unless ingredient is a gas. Gas concentrations are in percent by volume. SDS_North America - 200000000693 Revision Date: 07/15/2021

Notes

The term “Hazardous Ingredients” should be interpreted as a term defined in Hazard Communication standards and does not necessarily imply the existence of a welding hazard. The product may contain additional non-hazardous ingredients or may form additional compounds under the condition of use. Refer to Sections 2 and 8 for more information.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air if breathing is difficult. If breathing has stopped, perform artificial respiration and obtain medical assistance at once.

Symptoms: Short-term (acute) overexposure to fumes and gases from welding and allied processes may result in discomfort such as metal fume fever, dizziness, nausea, or dryness or irritation of nose, throat. May aggravate pre-existing respiratory problems (e.g. asthma, emphysema). Long-term (chronic) overexposure to fumes and gases from welding and allied processes can lead to siderosis (iron deposits in lung), central nervous system effects, bronchitis and other pulmonary effects.

Skin contact

Remove contaminated clothing and wash the skin thoroughly with soap and water. For reddened or blistered skin, or thermal burns, obtain medical assistance at once.

Symptoms: Reddened or blistered skin, or thermal burns.

Eye contact

Dust or fume from this product should be flushed from the eyes with copious amounts of clean, tepid water until transported to an emergency medical facility. Do not allow victim to rub or keep eyes tightly closed. Obtain medical assistance at once. If exposed to arc rays, move victim to dark room, remove contact lenses as necessary for treatment, cover eyes with a padded dressing and rest.

Symptoms: Irritation of eyes. Arc rays can injure eyes.

Ingestion

If ingested, do not induce vomiting. Contact a poison control center. Unless the poison control center advises otherwise, wash out mouth thoroughly with water.

Immediate Medical Attention

If symptoms develop, seek medical attention at once. Obtain medical assistance at once for inhalation, skin contact, and eye contact.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

As shipped, the product will not burn. In case of fire in the surroundings: use appropriate extinguishing agent.

Unsuitable media

Do not use water jet as an extinguisher, as this will spread the fire.

Specific hazards

Welding arc and sparks can ignite combustibles and flammable products.

Instructions

Use standard firefighting procedures and consider the hazards of other involved materials.

Firefighter Protection

Selection of respiratory protection for fire fighting: follow the general fire precautions indicated in the workplace. Self-contained breathing apparatus and full protective clothing must be worn in case of fire.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

If airborne dust and/or fume is present, use adequate engineering controls and, if needed, personal protection to prevent overexposure. Refer to recommendations in Section 8.

Environmental

Avoid release to the environment. Prevent further leakage or spillage if safe to do so. Do not contaminate water sources or sewer. Environmental manager must be informed of all major spillages.

Cleanup methods

Absorb with sand or other inert absorbent. Clean up spills immediately, observing precautions in the personal protective equipment in Section 8.

Materials: sand or other inert absorbent

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Prevent formation of dust. Provide appropriate exhaust ventilation at places where dust is formed. Read and understand the manufacturer's instruction and the precautionary label on the product. Refer to Lincoln Safety Publications at www.lincolnelectric.com/safety. See American National Standard Z49.1, "Safety In Welding, Cutting and Allied Processes" published by the American Welding Society, http://pubs.aws.org and OSHA Publication 2206 (29CFR1910), U.S. Government Printing Office, www.gpo.gov.

Storage

Store in closed original container in a dry place. Store in accordance with local/regional/national regulations. Store away from incompatible materials.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use enough ventilation and local exhaust at the arc, flame or heat source to keep the fumes and gases from the worker's breathing zone and the general area. Train the operator to keep their head out of the fumes. Keep exposure as low as possible.

Hands

Wear protective gloves. Suitable gloves can be recommended by the glove supplier. At a minimum, this includes welder's gloves. Wear dry gloves free of holes or split seams.

Eyes

Wear helmet or use face shield with filter lens shade number 12 or darker for open arc processes – or follow the recommendations as specified in ANSI Z49.1, Section 4, based on your process and settings. No specific lens shade recommendation for submerged arc or electroslag processes. Shield others by providing appropriate screens and flash goggles.

Respiratory

Keep your head out of fumes. Use enough ventilation and local exhaust to keep fumes and gases from your breathing zone and the general area. An approved respirator should be used unless exposure assessments are below applicable exposure limits.

Skin/Body

Wear hand, head, and body protection which help to prevent injury from radiation, open flames, hot surfaces, sparks and electrical shock. See Z49.1. At a minimum, this includes welder's gloves and a protective face shield when welding, and may include arm protectors, aprons, hats, shoulder protection, as well as dark substantial clothing when welding, brazing and soldering. Train the operator not to permit electrically live parts or electrodes from contacting the skin . . . or clothing or gloves if they are wet. Insulate yourself from the work piece and ground using dry plywood, rubber mats or other dry insulation.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
Steel rod with extruded flux coating.
Colour
---
Colour Intensity
---
Form
Solid
Odor
---
Odor Threshold
---
Ph
---
Melting Point
---
Boiling Point
---
Flash Point
---
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Material is stable under normal conditions.

Reactivity

The product is non-reactive under normal conditions of use, storage and transport.

Hazardous reactions

None under normal conditions.

Avoid

Avoid heat or contamination.

Incompatible

Strong acids. Strong oxidizing substances. Strong bases.

Decomposition

Fumes and gases from welding and its allied processes such as brazing and soldering cannot be classified simply. The composition and quantity of both are dependent upon the metal to which the joining or hot work is applied, the process, procedure - and where applicable - the electrode or consumable used. Other conditions which also influence the composition and quantity of the fumes and gases to which workers may be exposed include: coatings on the metal being welded or worked (such as paint, plating, or galvanizing), the number of operators and the volume of the work area, the quality and amount of ventilation, the position of the operator's head with respect to the fume plume, as well as the presence of contaminants in the atmosphere (such as chlorinated hydrocarbon vapors from cleaning and degreasing activities.) In cases where an electrode or other applied material is consumed, the fume and gas decomposition products generated are different in percent and form from the ingredients listed in Section 3. Decomposition products of normal operation include those originating from the volatilization, reaction, or oxidation of the materials shown in Section 3, plus those from the base metal and coating, etc., as noted above. Reasonably expected fume constituents produced during arc welding and brazing include the oxides of iron, manganese and other metals present in the welding consumable or base metal. Hexavalent chromium compounds may be in the welding or brazing fume of consumables or base metals which contain chromium. Gaseous and particulate fluoride may be in the fume of consumables or flux materials which contain fluoride. Gaseous reaction products may include carbon monoxide and carbon dioxide. Ozone and nitrogen oxides may be formed by the radiation from the arc associated with welding.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Murex® 7018 MR®?

The signal word is no signal word.

What is the physical form of Murex® 7018 MR®?

Murex® 7018 MR® is a solid appearing as steel rod with extruded flux coating. .

What is Murex® 7018 MR® used for?

SMAW (Shielded Metal Arc Welding)

What are the hazard statements for Murex® 7018 MR®?

This substance has 1 hazard statement:

  • Not applicable