Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
Arcair Protex Alclean Aluminum Cleaner is a yellow liquid substance commonly used cleaning and removal of grease, oil, dirt and white, chalky aluminum oxides before welding. removes weld residue and discoloration after welding..
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS05
GHS06
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H290: May be corrosive to metals.
- H301: Toxic if swallowed
- H311: Toxic in contact with skin
- H331: Toxic if inhaled
Precautionary Statements
- Use on a well-ventilated area.
- Do not breathe fume/mist/vapors/spray.
- Wash face, hands and any exposed skin thoroughly after handling.
- Wear protective gloves/protection clothing/eye protection/face protection.
- Immediately call poison center or doctor/physician
- IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present. Continue rinsing. Call poison center or doctor/physician.
- IF ON SKIN (hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower. Wash contaminated clothing before reuse.
- IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. Call doctor/physician.
- Store in a well-ventilated environment. Keep container tightly closed.
- Dispose of contents/container according to State, Federal and Providential regulations.
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Thermadyne Tweco
distributor
Wichita, KS 67277
US
Dynaflux, Inc.
manufacturer
241 Brown Farm Rd. Cartersville, GA 30120 U.S.A.
US
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
CHEM-TEL
800-255-3924
US
For U.S.
CHEM-TEL
813-248-0585
US
International
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Phosphoric Acid | N/A | 5% | โ Non-hazardous |
| Ammonium Bifloride EC: 215-676-4 | 1341-49-7 | 1% | โ Non-hazardous |
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. Call doctor/physician.
Symptoms:
Inhalation causes irritation and burning to nose and throat.
๐๏ธ Skin Contact
IF ON SKIN (hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower. Wash contaminated clothing before reuse.
Symptoms:
Causes skin burns and eye damage.
๐๏ธ Eye Contact
Hold eyelids apart, initiate and maintain gentle and continuous irrigation for 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Symptoms:
Causes skin burns and eye damage.
๐ฝ๏ธ Ingestion/Swallowing
IF SWALLOWED: rinse mouth. DO NOT INDUCE VOMITING.
Symptoms:
Ingestion may cause severe burns to mouth, throat or stomach.
๐จ Immediate Medical Attention Required
Immediately call poison center or doctor/physician.
Medical Treatment
Treat symptomatically
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
Apply technical measures to comply with the occupational exposure limits. Eyewash stations. Showers.
๐งค Hand Protection
Chemical resistant, impermeable gloves.
๐๏ธ Eye Protection
Chemical anti-splash safety goggles.
๐ท Respiratory Protection
Ensure adequate ventilation, especially in confined areas. Ventilate by opening all doors and windows. If exposure above the TLV or EL require a NIOSH approved respirator equipped for the exposure or suitable respiratory protection per 29 CFR 1910.134 is required.
๐ฆบ Skin/Body Protection
Wear appropriate chemical resistant clothing.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
๐ท๏ธ UN Number
NA1760
๐ฆ Proper Shipping Name
Compounds, cleaning liquid (Phosphoric acid)
โ ๏ธ Transport Hazard Class
8
๐ Packing Group
II
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for Arcair Protex Alclean Aluminum Cleaner?
The signal word for this substance is "danger".
What is the physical form of Arcair Protex Alclean Aluminum Cleaner?
Arcair Protex Alclean Aluminum Cleaner is a liquid appearing as yellow liquid with amber color.
What is Arcair Protex Alclean Aluminum Cleaner used for?
Cleaning and removal of grease, oil, dirt and white, chalky aluminum oxides before welding. Removes weld residue and discoloration after welding.
What are the hazard statements for Arcair Protex Alclean Aluminum Cleaner?
This substance has 4 hazard statements: H290: May be corrosive to metals. H301: Toxic if swallowed H311: Toxic in contact with skin H331: Toxic if inhaled